
AN2323
... Sensor: The sensor detects the current pulses of the pulse count LED and thereby shows the error on the error calculator screen. As can be seen from the block diagram, the sensor is connected to the error calculator. ...
... Sensor: The sensor detects the current pulses of the pulse count LED and thereby shows the error on the error calculator screen. As can be seen from the block diagram, the sensor is connected to the error calculator. ...
PLATINblue MSQ Plus Mass Spectrometer Pre
... Electrostatic discharge (ESD) can damage the electronic components of your MSQ Plus Mass Detector. The MSQ Plus Mass Detector can withstand electrostatic discharges (ESD) up to 8 kV (air discharge) and 4 kV (contact discharge) with all panels in place. However, if the panels are removed and the PCBs ...
... Electrostatic discharge (ESD) can damage the electronic components of your MSQ Plus Mass Detector. The MSQ Plus Mass Detector can withstand electrostatic discharges (ESD) up to 8 kV (air discharge) and 4 kV (contact discharge) with all panels in place. However, if the panels are removed and the PCBs ...
GFCI 2012 Field Representative Presentation
... UL943 Max 6 mA - threshold for “let-go” current. IEC Min 20 mA - threshold current for ventricular fibrillation. Receptacle End of Life indication Grounded Neutral protection Portable units - Load protection if both supply neutral and ground conductors are open together. ...
... UL943 Max 6 mA - threshold for “let-go” current. IEC Min 20 mA - threshold current for ventricular fibrillation. Receptacle End of Life indication Grounded Neutral protection Portable units - Load protection if both supply neutral and ground conductors are open together. ...
In depth Specifications
... B. Battery - Upon failure of utility / mains AC power, the critical AC load is supplied by the inverter, which obtains power from the battery. There is no interruption in power to the critical load upon failure or restoration of the utility / mains AC source. C. Recharge - Upon restoration of utilit ...
... B. Battery - Upon failure of utility / mains AC power, the critical AC load is supplied by the inverter, which obtains power from the battery. There is no interruption in power to the critical load upon failure or restoration of the utility / mains AC source. C. Recharge - Upon restoration of utilit ...
MAX3233E/MAX3235E ±15kV ESD-Protected, 1µA, 250kbps, 3.3V/5V, Dual RS-232 Transceivers with Internal Capacitors
... revolutionary AutoShutdown Plus™ feature. These devices automatically enter a low-power shutdown mode when the following two conditions occur: either the RS-232 cable is disconnected or the transmitters of the connected peripherals are inactive, and the UART driving the transmitter inputs is inactiv ...
... revolutionary AutoShutdown Plus™ feature. These devices automatically enter a low-power shutdown mode when the following two conditions occur: either the RS-232 cable is disconnected or the transmitters of the connected peripherals are inactive, and the UART driving the transmitter inputs is inactiv ...
Features
... The patented DataGATE technology was developed to permit a straightforward approach to additional power reduction. Each I/O pin has a series switch that can block the arrival of free running signals that are not of interest. Signals that serve no use may increase power consumption, and can be disabl ...
... The patented DataGATE technology was developed to permit a straightforward approach to additional power reduction. Each I/O pin has a series switch that can block the arrival of free running signals that are not of interest. Signals that serve no use may increase power consumption, and can be disabl ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP
... Susquehanna-Roseland corridor for interconnections to the existing offsite power transmission grid as shown in Figure 8.2-1. The two circuits are supported on separate structures, which are located to minimize the likelihood of simultaneous failure. Transmission tower separation, line installation, ...
... Susquehanna-Roseland corridor for interconnections to the existing offsite power transmission grid as shown in Figure 8.2-1. The two circuits are supported on separate structures, which are located to minimize the likelihood of simultaneous failure. Transmission tower separation, line installation, ...
Switching Control Technique of Phase-Shift- Controlled Full
... significant due to contribution by the circulating current. 3) A small inductor and large capacitor are added to generate a constant voltage source on secondary side, as proposed in [10]. Although the circulating current is reduced and the zero-current switching (ZCS) is achieved by leading leg of f ...
... significant due to contribution by the circulating current. 3) A small inductor and large capacitor are added to generate a constant voltage source on secondary side, as proposed in [10]. Although the circulating current is reduced and the zero-current switching (ZCS) is achieved by leading leg of f ...
PDF: 2.09MB
... for a Sustainable Future Traction, industrial equipment, building facilities, electric vehicles, renewable energies, home appliances... Power devices are a key component in power electronics products for contributing to the realization of a low-carbon society. Attracting attention as the most energy ...
... for a Sustainable Future Traction, industrial equipment, building facilities, electric vehicles, renewable energies, home appliances... Power devices are a key component in power electronics products for contributing to the realization of a low-carbon society. Attracting attention as the most energy ...
brochure here
... The Ceramic Infrared Bulb is primarily used in the area of animal / pet healthcare. Bulb infrared heaters available from 60 to 400 watts. ...
... The Ceramic Infrared Bulb is primarily used in the area of animal / pet healthcare. Bulb infrared heaters available from 60 to 400 watts. ...
AK1543 - Asahi Kasei Microdevices
... The internal timer is used to switch those two charge pumps to achieve a fast lock PLL. The loop filter is external and connected to [CP], [SWIN] and [CPZ] pins. The [CPZ] pin should be connected to the R2 and C2 , which are intermediate nodes, even if the Fast Lockup is not used. Therefore, R2 must ...
... The internal timer is used to switch those two charge pumps to achieve a fast lock PLL. The loop filter is external and connected to [CP], [SWIN] and [CPZ] pins. The [CPZ] pin should be connected to the R2 and C2 , which are intermediate nodes, even if the Fast Lockup is not used. Therefore, R2 must ...
MAX9789/MAX9790 Windows Vista-Compliant, Stereo Class AB Speaker Amplifiers and DirectDrive Headphone Amplifiers
... The LDO output voltage is set internally at 4.75V or can be adjusted between 1.21V and 4.75V using a simple resistive divider. The LDO is protected against thermal overloads and short circuits while providing 120mA of continuous output current and can be enabled independently of the audio amplifiers ...
... The LDO output voltage is set internally at 4.75V or can be adjusted between 1.21V and 4.75V using a simple resistive divider. The LDO is protected against thermal overloads and short circuits while providing 120mA of continuous output current and can be enabled independently of the audio amplifiers ...
Document
... Transmission lines causes power loss, radio and television interference, and audible noise (in terms of buzzing, hissing, or frying sounds) in the vicinity of the line. At extra highvoltage levels (i.e., at 345 kV and higher), the conductor itself is the major source of audible noise, radio interfer ...
... Transmission lines causes power loss, radio and television interference, and audible noise (in terms of buzzing, hissing, or frying sounds) in the vicinity of the line. At extra highvoltage levels (i.e., at 345 kV and higher), the conductor itself is the major source of audible noise, radio interfer ...
Hardware Manual - RTD Embedded Technologies, Inc.
... working quickly, while also providing enough detail about the board and it's functions so that you can enjoy maximum use of it's features even in the most demanding applications. ...
... working quickly, while also providing enough detail about the board and it's functions so that you can enjoy maximum use of it's features even in the most demanding applications. ...
Sensorless Start-up and Control of Permanent Magnet Synchronous
... of subsea pump motors with long tieback distance and high breakaway torque becomes more and more relevant. Lack of sufficient expertise and right tools for analyses and calculations can easily lead to over dimensioned components; along with its unwanted consequences on component size, weight and cos ...
... of subsea pump motors with long tieback distance and high breakaway torque becomes more and more relevant. Lack of sufficient expertise and right tools for analyses and calculations can easily lead to over dimensioned components; along with its unwanted consequences on component size, weight and cos ...
Keysight Technologies U1240 Series Handheld Digital Multimeters
... 03 | Keysight | U1240 Series Handheld Digital Multimeters - Data Sheet ...
... 03 | Keysight | U1240 Series Handheld Digital Multimeters - Data Sheet ...