• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Ambiguity of the Peak Power Rating of TVS Devices
Ambiguity of the Peak Power Rating of TVS Devices

power-scaling.pdf
power-scaling.pdf

... with diodes to ground at each bottom leg of the wiper to reduce the staic power disipated by the control. DISCLAIMER: I haven't seen any schematics either, but I have tried to grok my way through the book. If you think about it the actual power disipated by say a 10K dual ganged pot across a 300VRMS ...
AC Adapters - Mode Electronics
AC Adapters - Mode Electronics

... 68-650-1 will be replaced with the 68-6500S-1 when current stock is depleted. 68-650P-1 will be replaced with the 68-6500PS-1 when current stock is depleted. 68-950-1 is now replaced by 68-9006S-1 (600mA). 68-950P-1 will be replaced with the 68-9006PS-1 (600mA) when current stock is depleted. 68-121 ...
SERIES II 20 amp powER CondItIonERS
SERIES II 20 amp powER CondItIonERS

... circuit AC load, within a typical tolerance of +/0.5 amp. Because these meters feature true R.M.S. technology, the current readings are accurate regardless of load conditions (capacitive, inductive or resistive). NOTE: The PL-PRO II, PL-PRO D II, and PMPRO D II, do not compensate for high or low lin ...
Microgrids Modelling Testing - Spiral
Microgrids Modelling Testing - Spiral

... system-level dynamics are dictated by the main grid due to the relatively small size of micro sources. In stand-alone mode, the system dynamics are dictated by micro sources, the network and the nature of the power regulation control. One of the important aspects of such a low inertia systems is the ...
Feedback Control of Five-Level PWM Rectifier: Application to the S
Feedback Control of Five-Level PWM Rectifier: Application to the S

... application of the proposed feedback control algorithm to the rectifier shows a good voltage tracking. Feedback control algorithm of the rectifier associated with clamping bridge filter makes stable the input DC voltages of five-level APF. The proposed control algorithm opens the door to different a ...
GR-17-01 - GRid-connected Advanced Power Electronics Systems
GR-17-01 - GRid-connected Advanced Power Electronics Systems

Multilevel Power Converter Based on a Three Single
Multilevel Power Converter Based on a Three Single

Aalborg Universitet
Aalborg Universitet

... presented in [2] and [3] is based on using a two-inverter structure connecting one in shunt and the other in series to the grid, like a series-parallel active power filter [4]. The main role of the shunt inverter is to control active and reactive power flow, while the series inverter balances the li ...
AN-376 Logic-System Design Techniques Reduce Switching-CMOS Power AN-
AN-376 Logic-System Design Techniques Reduce Switching-CMOS Power AN-

... Total system power dissipation is the sum of two components: static (or quiescent) and dynamic power. LS TTL systems consume such a great amount of quiescent power that the dynamic component pales into insignificance. When using MM74HC logic in power-critical applications, however, you must consider ...
Keysight Technologies U1881A and U1882B Measurement
Keysight Technologies U1881A and U1882B Measurement

... 02 | Keysight | U1881A and U1882B Measurement Application for InfiniiVision and Infiniium Oscilloscopes - Data Sheet ...
A Soft-Switched High Frequency Converter for Wide Voltage and
A Soft-Switched High Frequency Converter for Wide Voltage and

... conversion, and prohibits operation in the MHz regime with hard switching. This loss can be avoided by circuit operation which allows switch voltages to decrease before the switches are turned on; this type of “soft” switching is known as zerovoltage switching (ZVS). While many converters can use ZV ...
A Tutorial on the Decibel
A Tutorial on the Decibel

... measure the transmitter output power again. This time we find that the output power has increased to 20 W. What is the power increase, in dB? Equation 2 will help us answer this question. P  dB = 10 log  1   P0   20 W  dB = 10 log  ...
Presentation 1 - Sandip - Atomic Scale Design Network (ASDN)
Presentation 1 - Sandip - Atomic Scale Design Network (ASDN)

... Technique permits the body voltage to be switched with the gate voltage. High threshold voltages in standby mode result in low leakage currents. Low threshold voltage in active mode allow for higher current drives (high speed). ...
Engineering Presentation
Engineering Presentation

Electronics IEEE Projects
Electronics IEEE Projects

RF Power Amplifiers – Just how do they Rate
RF Power Amplifiers – Just how do they Rate

... are close to the original two frequencies, separated by only the difference of the input frequencies. This particular intermodulation pair is the third order products. Fifth and higher order products are also generated but usually at much smaller levels than the third order products. To measure the ...
all  other  uses,  in  any ... © 2013 IEEE
all other uses, in any ... © 2013 IEEE

... grid-connected PV systems, it is found that the even order voltage harmonic ripples at the DC side (PV panels) may still distort the injected current, leading to a poor current THD. Meanwhile, it can also be summarized from the test data that the harmonic current level varies with the injected curre ...
PROGRAMMABLE DC ELECTRONIC LOAD MODEL 63200 SERIES
PROGRAMMABLE DC ELECTRONIC LOAD MODEL 63200 SERIES

... Modern electronic devices operate at very high speeds; therefore, it is important for an electronic load to perform well during the transient and dynamic testing. To satisfy these testing applications, the 63200 loads offer outstanding high speed, programmable dynamic load simulation and control cap ...
Configuration and Selection of Microwave Generators
Configuration and Selection of Microwave Generators

... The magnetron head consists of a magnetron, waveguide launcher, filament transformer and both the electrical and mechanical systems required to generate and propagate the microwave energy. All system sub components have been designed to offer the highest level of performance, stability, and system e ...
Available Information on Voltage Sags and Interruptions
Available Information on Voltage Sags and Interruptions

... Power distribution systems have a tree-like structure. Higher voltage main distribution feeders give way to lower voltage local feeders and ultimately to the drop wires to individual homes and businesses. These feeders are usually equipped with both fusible links and “reclosers”. A recloser is a cir ...
PL512/PL506 Modular Power Supply System Technical Manual 6. June 2011
PL512/PL506 Modular Power Supply System Technical Manual 6. June 2011

... The only purpose of this manual is a description of the product. It must not be interpreted as a declaration of conformity for this product including the product and software. W-Ie-Ne-R revises this product and manual without notice. Differences of the description in manual and product are possible. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

RA07M4047M 数据资料DataSheet下载
RA07M4047M 数据资料DataSheet下载

... reliable for their designed purpose, they are not manufactured under a quality assurance testing protocol that is sufficient to guarantee the level of reliability typically deemed necessary for critical communications elements. Examples of critical communications elements would include transmitters ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

< 1 ... 92 93 94 95 96 97 98 99 100 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report