
PSoC 4 Programmable Gain Amplifier (PGA_P4)
... The Programmable Gain Amplifier uses one of the amplifiers and resistor blocks found in the CTB (see Definitions) to create a user adjustable gain non-inverting amplifier. Two PGAs can be created from a single CTB block. You can find details about this block in the applicable device datasheet and TR ...
... The Programmable Gain Amplifier uses one of the amplifiers and resistor blocks found in the CTB (see Definitions) to create a user adjustable gain non-inverting amplifier. Two PGAs can be created from a single CTB block. You can find details about this block in the applicable device datasheet and TR ...
FTB 723-1 Equipment Reference Manual P/N
... every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
... every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
Lectures 10-11 Effect of source inductance on phase controlled AC
... account the commutation. If the converter input voltage terminals are shared with other loads, (these voltages are invariably used as signals which control the triggering of the thyristors), then adequate filter circuits must be used to reduce the commutation notches to acceptable levels. If these n ...
... account the commutation. If the converter input voltage terminals are shared with other loads, (these voltages are invariably used as signals which control the triggering of the thyristors), then adequate filter circuits must be used to reduce the commutation notches to acceptable levels. If these n ...
PDF: 2.09MB
... for a Sustainable Future Traction, industrial equipment, building facilities, electric vehicles, renewable energies, home appliances... Power devices are a key component in power electronics products for contributing to the realization of a low-carbon society. Attracting attention as the most energy ...
... for a Sustainable Future Traction, industrial equipment, building facilities, electric vehicles, renewable energies, home appliances... Power devices are a key component in power electronics products for contributing to the realization of a low-carbon society. Attracting attention as the most energy ...
rail mounted power network meter n43 n43 type user`s manual
... The N43 meter,assembled on a rail, is a programmable digital instrument designed for the measurement of 3-phase, 3 or 4-wire power network parameters in balanced or unbalanced systems. The measured values are displayed on a dedicated LCD display. The meter enables control and optimization of the pow ...
... The N43 meter,assembled on a rail, is a programmable digital instrument designed for the measurement of 3-phase, 3 or 4-wire power network parameters in balanced or unbalanced systems. The measured values are displayed on a dedicated LCD display. The meter enables control and optimization of the pow ...
Demonstration of a Fiber Powered Extender for PON
... passive optical network (G-PON) or gigabit Ethernet passive optical network (GE-PON), are recognized as market leaders in optical access deployments. The natural evolution of these networks converges for 10 gigabit passive optical network (XG-PON or 10G-PON), but coexisting in the same infrastructur ...
... passive optical network (G-PON) or gigabit Ethernet passive optical network (GE-PON), are recognized as market leaders in optical access deployments. The natural evolution of these networks converges for 10 gigabit passive optical network (XG-PON or 10G-PON), but coexisting in the same infrastructur ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
... short-circuit faults[1]-[2]. There are renewable energy based generators (e.g. wind, solar) in the grid that can have varying output generation capabilities. Furthermore, the exponentially increasing power demand and popularity of distributed generation have resulted in increasing fault current leve ...
... short-circuit faults[1]-[2]. There are renewable energy based generators (e.g. wind, solar) in the grid that can have varying output generation capabilities. Furthermore, the exponentially increasing power demand and popularity of distributed generation have resulted in increasing fault current leve ...
emtron dx-4 - RADIOMANUAL
... two computer type fans sucking air and positioned above the tubes. All fans operate at two speeds, controlled by 2 temperature sensors. Tetrodes offer exceptionally stable operation and levels of quality performance far exceeding that which can be expected from triodes. The harmonic output and inter ...
... two computer type fans sucking air and positioned above the tubes. All fans operate at two speeds, controlled by 2 temperature sensors. Tetrodes offer exceptionally stable operation and levels of quality performance far exceeding that which can be expected from triodes. The harmonic output and inter ...
PM3200 Series - Power Meters
... Specific Hazard Associated with Power Meters In the case of almost all electric and electronic devices, the device power supply is the root cause of electrical hazards. The hazard can be eliminated by disconnecting the power supply. So, this connection must be broken before carrying out any kind of ...
... Specific Hazard Associated with Power Meters In the case of almost all electric and electronic devices, the device power supply is the root cause of electrical hazards. The hazard can be eliminated by disconnecting the power supply. So, this connection must be broken before carrying out any kind of ...
LM4995 数据资料 dataSheet 下载
... from the classical single-ended amplifier configuration where one side of the load is connected to ground. A bridge amplifier design has a few distinct advantages over the single-ended configuration, as it provides differential drive to the load, thus doubling output swing for a specified supply vol ...
... from the classical single-ended amplifier configuration where one side of the load is connected to ground. A bridge amplifier design has a few distinct advantages over the single-ended configuration, as it provides differential drive to the load, thus doubling output swing for a specified supply vol ...
CQ23562567
... mainly of three categories such as series-connected compensator like dynamic voltage restorer (DVR), shunt connected compensator such as distribution static compensator (DSTATCOM), and a combination of series and shuntconnected compensators known as unified power quality conditioner (UPQC). A DVR is ...
... mainly of three categories such as series-connected compensator like dynamic voltage restorer (DVR), shunt connected compensator such as distribution static compensator (DSTATCOM), and a combination of series and shuntconnected compensators known as unified power quality conditioner (UPQC). A DVR is ...
ATX / ATX12V Power Supply Design Guide
... same typical +5 VDC and +3.3 VDC maximum continuous output currents as an ATX supply of the same total output power. To minimize cost, this may be accomplished via a load sharing arrangement, whereby the individual +12 VDC, +5 VDC, and +3.3 VDC output currents may trade off against each other but th ...
... same typical +5 VDC and +3.3 VDC maximum continuous output currents as an ATX supply of the same total output power. To minimize cost, this may be accomplished via a load sharing arrangement, whereby the individual +12 VDC, +5 VDC, and +3.3 VDC output currents may trade off against each other but th ...
-Through Capability of a Single-Stage Single-Phase Photovoltaic Low Voltage Ride -Voltage Grid
... Abstract- The progressively growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSO) to update or revise the existing grid codes in order to guarantee the availability, quality and reliability of the electrical system. It is expected that the future PV systems ...
... Abstract- The progressively growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSO) to update or revise the existing grid codes in order to guarantee the availability, quality and reliability of the electrical system. It is expected that the future PV systems ...
Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....
... elements forming PST, at symmetric regulation of phase shift between output and input voltages of device - Electromagnetic calculation of the laboratory sample elements by capacity 10 kVA on the voltage 220 V, providing step (14 steps) regulation of phase shift of output voltage in a range from ...
... elements forming PST, at symmetric regulation of phase shift between output and input voltages of device - Electromagnetic calculation of the laboratory sample elements by capacity 10 kVA on the voltage 220 V, providing step (14 steps) regulation of phase shift of output voltage in a range from ...
Switched Mode Converters (4 Quadrants)
... Linear dissipative Stage Basic background known, (push-pull stage) 4Q operation to be explained later Dissipation in the transistors, acting as ...
... Linear dissipative Stage Basic background known, (push-pull stage) 4Q operation to be explained later Dissipation in the transistors, acting as ...
CHRISTU JYOTI INSTITUTE OF TECHNOLOGY & SCIENCE LABORATORY MANUAL ELECTRICAL MACHINES II
... 21.Determine the correct rating of the fuse/s to be connected in the circuit after understanding correctly the type of the experiment to be performed: no-load test or fullload test, the maximum current expected in the circuit and accordingly use that fuserating.(While an over-rated fuse will damage ...
... 21.Determine the correct rating of the fuse/s to be connected in the circuit after understanding correctly the type of the experiment to be performed: no-load test or fullload test, the maximum current expected in the circuit and accordingly use that fuserating.(While an over-rated fuse will damage ...
MAX4410 80mW, DirectDrive Stereo Headphone Driver with Shutdown General Description
... The MAX4410 delivers up to 80mW per channel into a 16Ω load and has low 0.003% THD + N. A high powersupply rejection ratio (90dB at 1kHz) allows this device to operate from noisy digital supplies without an additional linear regulator. The MAX4410 includes ±8kV ESD protection on the headphone output ...
... The MAX4410 delivers up to 80mW per channel into a 16Ω load and has low 0.003% THD + N. A high powersupply rejection ratio (90dB at 1kHz) allows this device to operate from noisy digital supplies without an additional linear regulator. The MAX4410 includes ±8kV ESD protection on the headphone output ...
Power factor
In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.