• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN1722
AN1722

... Usually, after the striking, in order to increase the light efficiency, the tube works with a frequency around 25-50KHz, in fact, in this frequency range, the light output can increase up to 15 % for the same input energy. Generally, the common fluorescent lamps can be considered only as a resistive ...
Stability Analysis of a Microgrid System with a Constant Power Load
Stability Analysis of a Microgrid System with a Constant Power Load

... points of a DC microgrid are calculated allowing to study the local asymptotic stability properties of these equilibrium points. Due to the negative dynamic resistance of the CPL, stability problems can occur. The impact of the parameters in the model on the stability properties are studied in case ...
Automotive High Brightness LED Control Based on the
Automotive High Brightness LED Control Based on the

... The simple buck-boost topology shown in Figure 9 might look like an easy and cheap solution, but as stated in its transfer function (Equation 3), the output voltage is negative and referenced to VBAT. Because of this, the application requires a complex and expensive current feedback strategy to ensu ...
Title Synthesis of input-rectifierless AC/DC converters Author(s) Liu
Title Synthesis of input-rectifierless AC/DC converters Author(s) Liu

A Courseware Sample Electric Power / Controls 85822-F0
A Courseware Sample Electric Power / Controls 85822-F0

... When you have completed this exercise, you will be familiar with the operation of a boost chopper. DISCUSSION The Boost Chopper As discussed in the previous exercise of this manual, transformers allow AC voltage and current levels to be converted. For example, a step-up transformer is normally used ...
KB020
KB020

... Capacitors may physically hum as the harmonic currents flow through them. This is not generally harmful to the capacitors themselves unless high overvoltages as a result of the harmonics are also present. ...
Surge Protection for Surveillance Systems
Surge Protection for Surveillance Systems

... surge event affecting exterior equipment, (like cameras), can follow a path leading back into a building, affecting interior equipment as well. DVRs, interior cameras, midspans and power supplies may not have received the initial surge, but because these components are connected, the entire system i ...
PowerCenter HTS 3600 Manual
PowerCenter HTS 3600 Manual

... While your PowerCenter does an excellent job of protecting your components from harmful power surges, its main benefit is much more than just surge protection. Our exclusive Clean Power™ v.2.0 filter circuitry virtually stops the noise that goes right through typical surge protectors. There is more ...
Modified droop control scheme for load sharing
Modified droop control scheme for load sharing

... type control, and circular chain control (Chadorkar et al. 1993, Duan et al. 1999, Wu et al. 2000, Zong 2013) to achieve the rigid control on the voltage/current for load sharing. However, due to the long communication lines between the distantly placed DRs, such wired control approaches face the is ...
DC/AC Cascaded H-Bridge Multilevel Boost Inverter With No
DC/AC Cascaded H-Bridge Multilevel Boost Inverter With No

Surion - CSF ELEKTRO sro
Surion - CSF ELEKTRO sro

... Surion, a new manual motor starter line Designed for switching and protecting three phase induction motors of up to 30kW@400VAC and for loads with rated currents up to 63A Complete range of modular auxiliaries designed to be mounted without any tools Fuseless compact starter with necessary accessori ...
POWER ANALYZER 3390
POWER ANALYZER 3390

... • Measurements of fundamental wave voltage and current and their phases based on an accurate harmonic analysis are indispensable to motor analysis • Support of an incremental encoder allows detecting synchronization signals from a motor easily and accurately Electrical angle measurements are indispe ...
Basics of Electricity
Basics of Electricity

The approximation scheme for peak power driven voltage partitioning
The approximation scheme for peak power driven voltage partitioning

... bottleneck for circuit miniaturization. In practice, the dynamic power consumption due to charging and discharging the capacitance during transistor switching is still a very important factor in the total power consumption. It has been indicated in [1] that in a recent Intel high performance micropr ...
TE200A Power controllers Two-phase control of three
TE200A Power controllers Two-phase control of three

... or a thermal safety cut-out should be fitted in the cabinet. TE200A units may be bulkhead or DIN rail mounted. The units must be mounted with the heatsink positioned vertically, with no obstructions above or below which could inhibit or impede airflow. If several units are mounted in the same cabine ...
Energy Saving of Conservation Voltage Reduction Based on Load
Energy Saving of Conservation Voltage Reduction Based on Load

PowerLogic Multi-Circuit Meter
PowerLogic Multi-Circuit Meter

PWM Converter Power Density Barriers
PWM Converter Power Density Barriers

... reduction in the relative switching loss increase with switching frequency can be achieved by utilizing soft switching. The switching frequency increase can then be used to decrease the size of the inductive components and thus to decrease the converter’s total volume. However, there is an increase ...
Comparison of Distribution Transformer Losses and Capacity under
Comparison of Distribution Transformer Losses and Capacity under

... Basically, transformers model consist of ordinary parameters such as the leakage inductances and dc resistances, magnetizing inductances and core resistance that obtain from no-load test, short circuit test and dc test. In this model, stray losses that consist of eddy current losses in windings and ...
PDF
PDF

... controlling the upper shunt terminal, and narrower h2 for controlling the lower series terminal (h1 >> h2). Other operating details like logical equations used for generating gating signals for the three switches per phase would remain unchanged, as per (1). For h2 , a comment raised here is that it ...
Power Consumption Report - Mobile PC Extended Battery Life
Power Consumption Report - Mobile PC Extended Battery Life

... On a WLED backlit panel Power is consumed by both data and by the backlight system. Both systems must be measured individually. Data is driven from system typically at 3.3v ±10%. Backlight system is typically driven directly from battery. Batteries can contain 3 or more individual cells resulting in ...
ML15.051 - PULS Power Supply
ML15.051 - PULS Power Supply

... This device is designed for installation in an enclosure and is intended for the general use such as in industrial control, office, communication, and instrumentation equipment. Do not use this power supply in equipment, where malfunction may cause severe personal injury or threaten human life. ...
Aalborg Universitet Converters
Aalborg Universitet Converters

... the fundamental component of the phase voltage to the half of the dc-link voltage. The application of the discrete vectors results in an error between the applied voltage vector and the reference voltage vector as shown in Fig. 2. The time integral of the error voltage vector is known as the harmoni ...
EEE- Interview Question with Answers
EEE- Interview Question with Answers

... VA it gives backup. ups is also two types : on line and offline . online ups having high volt and amp for long time backup with with high dc voltage.but ups start with 12v dc with 7 amp. but inverter is startwith 12v,24,dc to 36v dc and 120amp to 180amp battery with long time backup. ...
Asynchronous generator
Asynchronous generator

< 1 ... 34 35 36 37 38 39 40 41 42 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report