• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Introduction to Power Factor - Wyandotte Municipal Services
Introduction to Power Factor - Wyandotte Municipal Services

... Service provides generation, transmission and distribution capacity to supply both real and reactive power to all its customers. ...


... phase is 0.25Ω. Calculate the additional resistance per phase to be inserted in the rotor circuit if  the speed is to be reduced to 480RPM for full load torque.                                                                               A  220V,  50Hz,  4  pole  single  phase  induction  motor  ha ...
AC Power Quality and Standards
AC Power Quality and Standards

Electrophoresis - University of Guelph
Electrophoresis - University of Guelph

... electric field which is dependent on ratio of charge to mass. Electrical Shock: The effect produced on the body, and in particular the nerves, by an electrical current passing through it. The magnitude of the shock depends on the current flow, usually measured in milliamperes (mA) rather than by vol ...
10EE36-Electric Power Generation(EPG) Unit 7 lecture
10EE36-Electric Power Generation(EPG) Unit 7 lecture

... breakers with lower short circuit current breaking capacity and consequently less expensive circuit breakers. ...
Example 5 Solution
Example 5 Solution

Power ratings Power: a measure of how quickly energy is transferred.
Power ratings Power: a measure of how quickly energy is transferred.

... Students must fill in the name of the appliance and note down its ‘power rating’ e.g. 20 W. Students should then try to categorise the appliances into high/medium/low - this will help the students to think about which use more power than others. Task 3 More able students could then complete task 3 – ...
Power Quality 101
Power Quality 101

... include rectifiers (power supplies, UPS units, discharge lighting), adjustable speed motor drives, DC motor drives and arcing equipment. ...
Power Factor Improvement Experiment # 4 Power Factor
Power Factor Improvement Experiment # 4 Power Factor

... equally divided, resulting in a net power dissipation of zero. However, in circuits with mixed resistance and reactance like this one, the power waveform will still alternate between positive and negative, but the amount of positive power will exceed the amount of negative power. In other words, the ...
MQ 90S
MQ 90S

... that require all of the satellite speakers to be wired directly to the subwoofer, the MQ 90S can be parallel wired anywhere along the constant voltage wire pair. The high power transducer is a unique 8” woofer design that achieves truly impressive performance for its size when matched with the speci ...
Liebert LTS (10A/16A/32A) Power Redundancy for One-way Power Supply for Business-Critical Continuity™
Liebert LTS (10A/16A/32A) Power Redundancy for One-way Power Supply for Business-Critical Continuity™

Electrical power is usually taken for granted and once a piece of
Electrical power is usually taken for granted and once a piece of

loss-free resistor-based power factor correction using a
loss-free resistor-based power factor correction using a

7810-12
7810-12

... • Dynamic voltage scaling – since we are changing frequency, can also combine it with voltage scaling as each circuit has longer slack – has a more than quadratic effect on dynamic power, a linear effect on leakage power, and a more than linear effect on energy • Intel Xscale: roughly 50ms to scale ...
Evaluation of Integrated Circuit Power Supply Noise with Two
Evaluation of Integrated Circuit Power Supply Noise with Two

H5CPE2
H5CPE2

Corrector Magnet Power Supplies for Indus-2
Corrector Magnet Power Supplies for Indus-2

... capacitor value has been chosen such that its voltage increases by less than 10 volts even if it absorbs the total energy stored in the magnet. The inverter uses MOSFETs switched at 30 kHz employing unipolar switching scheme as shown in Fig 1. Output of the inverter is filtered by LC filter and fed ...
GLOSSARY ON POWER
GLOSSARY ON POWER

MFJ-1116 Deluxe Multiple DC Power Outlets
MFJ-1116 Deluxe Multiple DC Power Outlets

... carry a maximum of 5 amps at 12 VDC. Do NOT connect your HF radio to the MFJ-1116. It was designed to supply DC power to your station accessories only. The MFJ-1116 can NOT be used for AC application. The DC output level of each pair of posts is dependent upon the DC level input going into the MFJ-1 ...
Harmonic Compensation With Zero-Sequence
Harmonic Compensation With Zero-Sequence

T5 Ballasts for Today`s High Efficiency Lighting Fixtures
T5 Ballasts for Today`s High Efficiency Lighting Fixtures

MPS CONFIDENTIAL DO N OT DISTRIBUTE
MPS CONFIDENTIAL DO N OT DISTRIBUTE

JH3416821685
JH3416821685

chapter 8 - Power Quality
chapter 8 - Power Quality

... The solution to transients problems is the installation of surge protection equipment. While some utilities install surge suppression equipment on their distribution lines it is still necessary for the customer to install equipment in their home or business. Wiring solutions include using special ci ...
notes
notes

< 1 ... 225 226 227 228 229 230 231 232 233 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.