speed control of dc motor using combined armature and field control
... poles). In all DC motors, except permanent magnet brushless motors, current must be conducted to the armature windings by passing current through carbon brushes that slide over a set of copper surfaces called a commutator, which is mounted on the rotor. The commutator bars are soldered to armature c ...
... poles). In all DC motors, except permanent magnet brushless motors, current must be conducted to the armature windings by passing current through carbon brushes that slide over a set of copper surfaces called a commutator, which is mounted on the rotor. The commutator bars are soldered to armature c ...
BP5041A
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
part 1 general - Rockwell Automation
... Remote Input/Output Unit: Include input/output modules, interface modules, communication modules, and power supply for system inputs and outputs. ...
... Remote Input/Output Unit: Include input/output modules, interface modules, communication modules, and power supply for system inputs and outputs. ...
D1U3CS-D-1600-HC4EC Series
... choice of 3.3V (20W) standby and airflow direction. The power module is able to current share with up to eight (8) other power modules of the same type operating in parallel or N+1 redundancy. The supplies may be hot plugged, and include integral isolation devices. The power modules are fully protect ...
... choice of 3.3V (20W) standby and airflow direction. The power module is able to current share with up to eight (8) other power modules of the same type operating in parallel or N+1 redundancy. The supplies may be hot plugged, and include integral isolation devices. The power modules are fully protect ...
GS2 Sensor (AGS2) - Panasonic Industrial Devices
... • Avoid use in a place where these products come in contact with water. • Avoid use in an environment where these products cause dew condensation. When water attached to the sensor chip freezes, the sensor output may be fluctuated or damaged. • Do not apply high-frequency oscillation, such as ultras ...
... • Avoid use in a place where these products come in contact with water. • Avoid use in an environment where these products cause dew condensation. When water attached to the sensor chip freezes, the sensor output may be fluctuated or damaged. • Do not apply high-frequency oscillation, such as ultras ...
Integration of PV/Battery Hybrid Energy Conversion
... a drawback that the total efficiency may become low if the number of stages are high, owing to power losses in the switching devices [4]. A quadratic converter configuration is also available that uses single switch and acheives quatratic gain [4]. An interesting attractive converter topology is a hig ...
... a drawback that the total efficiency may become low if the number of stages are high, owing to power losses in the switching devices [4]. A quadratic converter configuration is also available that uses single switch and acheives quatratic gain [4]. An interesting attractive converter topology is a hig ...
Control of DPGS Under Grid Faults
... The angle instability is cause by active power imbalance and by the excitation of mechanical generator dynamics. As a consequence the generators lose synchronism and they are disconnected. Voltage instability arises due lack of reactive power and as a consequence leads to overload of power lines ...
... The angle instability is cause by active power imbalance and by the excitation of mechanical generator dynamics. As a consequence the generators lose synchronism and they are disconnected. Voltage instability arises due lack of reactive power and as a consequence leads to overload of power lines ...
Modeling and Control of Three-Port DC/DC Converter Interface for
... bidirectional port to interface battery. To sum up, the multiport topologies can be classified into two categories: nonisolated topologies [1]–[9] and isolated topologies [10]–[23]. Nonisolated multiport converters usually take the form of buck, boost, buck–boost, etc., featuring compact design and ...
... bidirectional port to interface battery. To sum up, the multiport topologies can be classified into two categories: nonisolated topologies [1]–[9] and isolated topologies [10]–[23]. Nonisolated multiport converters usually take the form of buck, boost, buck–boost, etc., featuring compact design and ...
wjp-review4
... Learn about repetition (looping) control structures. Explore how to construct and use count-controlled, sentinel-controlled, flag-controlled, and EOFcontrolled repetition structures. Examine break and continue statements. Discover how to form and use nested control ...
... Learn about repetition (looping) control structures. Explore how to construct and use count-controlled, sentinel-controlled, flag-controlled, and EOFcontrolled repetition structures. Examine break and continue statements. Discover how to form and use nested control ...
A Luenberger-sliding mode observer with rotor
... and low cost. Although they were hardly used in digital applications until the 1980s because of slow response time and complicated control systems, recently they are used in applications of servo systems since the vector control algorithm has enabled them to have improved response time. The costs ca ...
... and low cost. Although they were hardly used in digital applications until the 1980s because of slow response time and complicated control systems, recently they are used in applications of servo systems since the vector control algorithm has enabled them to have improved response time. The costs ca ...
Physical Properties of Logic Devices
... • Some logic operates on 3.3 Volts, others on 12 Volts and yet other applications operate on a +12/-12 Volt logic. o many digital logic devices produce logic values that are not ideal. ...
... • Some logic operates on 3.3 Volts, others on 12 Volts and yet other applications operate on a +12/-12 Volt logic. o many digital logic devices produce logic values that are not ideal. ...
SGx524 Regulating Pulse-Width Modulators
... SGx524 is a fixed-frequency pulse-width-modulation (PWM) voltage-regulator control circuit. The regulator operates at a fixed frequency that is programmed by one timing resistor, RT, and one timing capacitor, CT. RT establishes a constant charging current for CT. This results in a linear voltage ram ...
... SGx524 is a fixed-frequency pulse-width-modulation (PWM) voltage-regulator control circuit. The regulator operates at a fixed frequency that is programmed by one timing resistor, RT, and one timing capacitor, CT. RT establishes a constant charging current for CT. This results in a linear voltage ram ...
RF2044A GENERAL PURPOSE AMPLIFIER Features
... cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. RoHS status based on EUDirective2 ...
... cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. RoHS status based on EUDirective2 ...
CONTROLLING HOME APPLIANCES USING REMOTE
... this frequency(38kHz). It is used to control relay RL2. The relay triggers IC2, which is wired in a bistable mode to control the home appliance connected at the contacts of relay RL1. iggeins6 and 2 of IC2 are held at one-half of the power supply voltage (5V) by resistors R2 and R3. When output pi ...
... this frequency(38kHz). It is used to control relay RL2. The relay triggers IC2, which is wired in a bistable mode to control the home appliance connected at the contacts of relay RL1. iggeins6 and 2 of IC2 are held at one-half of the power supply voltage (5V) by resistors R2 and R3. When output pi ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.