Sliding Mode Controller for Four Leg Shunt Active Power Filter to
... distribution systems and the amplitude of the zero sequence current is not reduced. To remedy these problems it will be necessary to provide a four leg shunt active power filter [11–14]. The four leg shunt active power filter topology, Fig.1, can reduce zero sequence current and the harmonic current ...
... distribution systems and the amplitude of the zero sequence current is not reduced. To remedy these problems it will be necessary to provide a four leg shunt active power filter [11–14]. The four leg shunt active power filter topology, Fig.1, can reduce zero sequence current and the harmonic current ...
LF411 Low Offset Low Drift JFET Input Operational Amplifier
... Note 6: The input bias currents are junction leakage currents which approximately double for every 10§ C increase in the junction temperature, Tj. Due to limited production test time, the input bias currents measured are correlated to junction temperature. In normal operation the junction temperatur ...
... Note 6: The input bias currents are junction leakage currents which approximately double for every 10§ C increase in the junction temperature, Tj. Due to limited production test time, the input bias currents measured are correlated to junction temperature. In normal operation the junction temperatur ...
Ultra Low Power PLL Implementations
... • Issues to take care of: – Spurs due to current mismatch – Charge injection/sharing while switching current on and off • M11 and M12 help match the PU and PD structures in the charge pump – Helps match charge injection and charge sharing effects ...
... • Issues to take care of: – Spurs due to current mismatch – Charge injection/sharing while switching current on and off • M11 and M12 help match the PU and PD structures in the charge pump – Helps match charge injection and charge sharing effects ...
MicroLogix - Literature Library
... analog inputs on every controller, with the ability to add digital, analog, RTD, and thermocouple modules to customize the controller for your application. On the versions of the controller with DC inputs, there is a high speed counter, and on the DC output version, two PTO/PWM (pulse train outputs ...
... analog inputs on every controller, with the ability to add digital, analog, RTD, and thermocouple modules to customize the controller for your application. On the versions of the controller with DC inputs, there is a high speed counter, and on the DC output version, two PTO/PWM (pulse train outputs ...
Circuits
... An S-R latch stores a single binary digit (1 or 0) There are several ways an S-R latch circuit can be designed using various kinds of gates Figure 4.12 An S-R latch ...
... An S-R latch stores a single binary digit (1 or 0) There are several ways an S-R latch circuit can be designed using various kinds of gates Figure 4.12 An S-R latch ...
BDTIC I Implementing Complex Motor Control Algorithms
... t1 and t2 are the projections of vα and vβ onto the two inverter voltage vectors that are the closest to the vector sum of vα + vβ. They represent the percentage of time that each switching state should be active to produce the desired voltage. When t1 + t2 < 100%, there is some time left called t0. ...
... t1 and t2 are the projections of vα and vβ onto the two inverter voltage vectors that are the closest to the vector sum of vα + vβ. They represent the percentage of time that each switching state should be active to produce the desired voltage. When t1 + t2 < 100%, there is some time left called t0. ...
GE - ECM Motor Technology and Troubleshooting
... If the shaft (with blower wheel disconnected) is difficult to turn with the motor control attached: - and turns freely with the control disconnected, then the control is damaged. - and does not turn free with the control disconnected, then the motor is damaged. Verify continuity of windings (motor l ...
... If the shaft (with blower wheel disconnected) is difficult to turn with the motor control attached: - and turns freely with the control disconnected, then the control is damaged. - and does not turn free with the control disconnected, then the motor is damaged. Verify continuity of windings (motor l ...
PWM5032 RadHard High Speed PWM Controller (3/15)
... The outputs have two modes of control depending on whether the 50% toggle option is selected. In the case where the 50% pin is logic low, the outputs are in-phase with each other and the duty cycle is free to take on any value up to 100%. However, when the 50% pin is asserted high (logic ''1''), the ...
... The outputs have two modes of control depending on whether the 50% toggle option is selected. In the case where the 50% pin is logic low, the outputs are in-phase with each other and the duty cycle is free to take on any value up to 100%. However, when the 50% pin is asserted high (logic ''1''), the ...
SBP270 Manual - Campbell Scientific
... The measurement result using a multiplier of 1.2 and an offset of 800 is true barometric pressure in mbars. The weather service and most airports, radio stations and TV stations correct the pressure recorded at a particular station to what it would be if the station was located at sea level. This is ...
... The measurement result using a multiplier of 1.2 and an offset of 800 is true barometric pressure in mbars. The weather service and most airports, radio stations and TV stations correct the pressure recorded at a particular station to what it would be if the station was located at sea level. This is ...
DS1020 Programmable 8-Bit Silicon Delay Line • FEATURES
... can be daisy-chained (cascaded) for programming purposes (Figure 3). The total number of serial bits must be eight times the number of units daisy-chained and each group of 8 bits must be sent in MSB-to-LSB order. Applications can read the setting of the DS1020 delay line by connecting the serial ou ...
... can be daisy-chained (cascaded) for programming purposes (Figure 3). The total number of serial bits must be eight times the number of units daisy-chained and each group of 8 bits must be sent in MSB-to-LSB order. Applications can read the setting of the DS1020 delay line by connecting the serial ou ...
3.0A, 150kHz, Step-Down Switching Regulator LM2596
... the LM2596 are offered by several different inductor manufacturers. Since the LM2596 converter is a switchmode power supply, its efficiency is significantly higher in comparison with popular three-terminal linear regulators, especially with higher input voltages. In many cases, the power dissipated ...
... the LM2596 are offered by several different inductor manufacturers. Since the LM2596 converter is a switchmode power supply, its efficiency is significantly higher in comparison with popular three-terminal linear regulators, especially with higher input voltages. In many cases, the power dissipated ...
Extend the I C-bus with advanced repeaters and hubs NXP 2-channel I
... Alternatives are recommended to support special conditions. For systems with very low voltage (down to 0.9 V), use the PCA9508/ 09/17A/19. For systems with up to 1500 pF, use the PCA9507, which has a rise-time accelerator. For systems larger than four segments, use the PCA9518A. For systems with rep ...
... Alternatives are recommended to support special conditions. For systems with very low voltage (down to 0.9 V), use the PCA9508/ 09/17A/19. For systems with up to 1500 pF, use the PCA9507, which has a rise-time accelerator. For systems larger than four segments, use the PCA9518A. For systems with rep ...
Automatic generation control of a wind farm with variable speed
... power, just after Germany and the United States [1]. Prospects for 2010 point to 8000-MW installed power from wind energy, which will represent a significant percentage of the total capacity in the Spanish electrical system. Nevertheless, in spite of this large installed wind power, reduced effort h ...
... power, just after Germany and the United States [1]. Prospects for 2010 point to 8000-MW installed power from wind energy, which will represent a significant percentage of the total capacity in the Spanish electrical system. Nevertheless, in spite of this large installed wind power, reduced effort h ...
Transceivers_for_Passive_Optical_Networks - Indico
... Commonly the bias current is set to zero only between bursts and it is set above threshold for the duration of the burst There are designs that suggest switching the laser current off even during ‘0’s In both cases Turn-on Delay Compensation (TODC) circuitry is required Also use of a shunt transisto ...
... Commonly the bias current is set to zero only between bursts and it is set above threshold for the duration of the burst There are designs that suggest switching the laser current off even during ‘0’s In both cases Turn-on Delay Compensation (TODC) circuitry is required Also use of a shunt transisto ...
LMC6001 Ultra Ultra-Low Input Current Amplifier (Rev. I)
... only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. If Military/Aerospace specified devices are re ...
... only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. If Military/Aerospace specified devices are re ...
speed control of dc motor using combined armature and field control
... poles). In all DC motors, except permanent magnet brushless motors, current must be conducted to the armature windings by passing current through carbon brushes that slide over a set of copper surfaces called a commutator, which is mounted on the rotor. The commutator bars are soldered to armature c ...
... poles). In all DC motors, except permanent magnet brushless motors, current must be conducted to the armature windings by passing current through carbon brushes that slide over a set of copper surfaces called a commutator, which is mounted on the rotor. The commutator bars are soldered to armature c ...
BP5041A
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
OP-AMP Basics Simple OP-AMP circuits
... http://media.digikey.com/pdf/Data%20Sheets/Fairchild%20PDFs/LM741.pdf). Some newer op-amps (Ex: LTC1151: http://cds.linear.com/docs/en/datasheet/1151fa.pdf) are chopper stabilized (i.e. they measure the offset and null it automatically many times a second). Chopper stabilized op-amps work best with ...
... http://media.digikey.com/pdf/Data%20Sheets/Fairchild%20PDFs/LM741.pdf). Some newer op-amps (Ex: LTC1151: http://cds.linear.com/docs/en/datasheet/1151fa.pdf) are chopper stabilized (i.e. they measure the offset and null it automatically many times a second). Chopper stabilized op-amps work best with ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.