
OPA551 OPA552 High-Voltage, High-Current OPERATIONAL AMPLIFIERS
... voltage swing, power supply voltages do not need to be equal. The OPA551 and OPA552 can operate with as little as 8V between the supplies or with up to 60V between the supplies. For example, the positive supply could be set to 50V with the negative supply at –10V or vice-versa. The SO-8 package outl ...
... voltage swing, power supply voltages do not need to be equal. The OPA551 and OPA552 can operate with as little as 8V between the supplies or with up to 60V between the supplies. For example, the positive supply could be set to 50V with the negative supply at –10V or vice-versa. The SO-8 package outl ...
Design Strategy for a 3-Phase Variable Frequency Drive (VFD)
... as the triangle wave generator can be seen in the appendix. In the other input the half-wave signals are fed. At this point we are still working with six signals and circuits, but it is necessary to use only one triangle wave for as a reference for everything. In addition to only one triangle wave, ...
... as the triangle wave generator can be seen in the appendix. In the other input the half-wave signals are fed. At this point we are still working with six signals and circuits, but it is necessary to use only one triangle wave for as a reference for everything. In addition to only one triangle wave, ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
... Much work has been presented using this type of converter [10-15]. Although the converter used in these works are extremely similar, great differences lie within the control strategy and complexity. One option is to apply vector control to the supply-side converter, with a reference frame orientated ...
... Much work has been presented using this type of converter [10-15]. Although the converter used in these works are extremely similar, great differences lie within the control strategy and complexity. One option is to apply vector control to the supply-side converter, with a reference frame orientated ...
Output short-circuit protection on a synchronous rectified flyback
... The converter is protected by the primary side PWM controller in Figure 1 during the short-circuit condition. The primary side controller permanently observes the feedback signal, knowing that it should be within a certain range for regulation. If the signal goes outside this range, there must be a ...
... The converter is protected by the primary side PWM controller in Figure 1 during the short-circuit condition. The primary side controller permanently observes the feedback signal, knowing that it should be within a certain range for regulation. If the signal goes outside this range, there must be a ...
Protection and control unit - Schneider Electric Belgique
... Alternative overcurrent setting groups will be selectable by logical conditions to adapt fast protection plan change as well as remote setting facilities for thresholds and time delay adjustments. The unit shall allow for the use of upstream and downstream logic discrimination in order to discrimina ...
... Alternative overcurrent setting groups will be selectable by logical conditions to adapt fast protection plan change as well as remote setting facilities for thresholds and time delay adjustments. The unit shall allow for the use of upstream and downstream logic discrimination in order to discrimina ...
Power system Stability Improvement using Fact Devices Prashant
... paradigms in tandem were used. The stability boundary was constructed using tangent hyper surfaces. ANNs were used to determine the unknown coefficients of the hyper surfaces independently of operating conditions. Numerical results and comparisons between CCT analytically obtained and ANN-based indi ...
... paradigms in tandem were used. The stability boundary was constructed using tangent hyper surfaces. ANNs were used to determine the unknown coefficients of the hyper surfaces independently of operating conditions. Numerical results and comparisons between CCT analytically obtained and ANN-based indi ...
Integrated D-STATCOM with Supercapacitor Used in IEEE Industrial Distribution System Amin Nazarloo
... face it. It contributes more than 80% of power quality problems that exist in power systems. Voltage sags are not tolerated by sensitive equipment used in modern industrial plants such as process controllers; programmable logic controllers (PLC), adjustable speed drive (ASD) and robotics [1]. Reacti ...
... face it. It contributes more than 80% of power quality problems that exist in power systems. Voltage sags are not tolerated by sensitive equipment used in modern industrial plants such as process controllers; programmable logic controllers (PLC), adjustable speed drive (ASD) and robotics [1]. Reacti ...
Autonomous Active Power Control for Islanded AC Microgrids
... decays sharply due to failure scenarios of ESS master unit, microgrid can take actions: i) enabling VCM control mode in CCM units to perform grid support [20]; ii) connecting backup equipment like diesel generators to support local loads. Multiple ESS can also be implemented in a coordinated way to ...
... decays sharply due to failure scenarios of ESS master unit, microgrid can take actions: i) enabling VCM control mode in CCM units to perform grid support [20]; ii) connecting backup equipment like diesel generators to support local loads. Multiple ESS can also be implemented in a coordinated way to ...
Aalborg Universitet Generation and Energy Storage System
... decays sharply due to failure scenarios of ESS master unit, microgrid can take actions: i) enabling VCM control mode in CCM units to perform grid support [20]; ii) connecting backup equipment like diesel generators to support local loads. Multiple ESS can also be implemented in a coordinated way to ...
... decays sharply due to failure scenarios of ESS master unit, microgrid can take actions: i) enabling VCM control mode in CCM units to perform grid support [20]; ii) connecting backup equipment like diesel generators to support local loads. Multiple ESS can also be implemented in a coordinated way to ...
FSL136MRT Green-Mode Fairchild Power Switch (FPS™) FSL136MRT — Green-Mode Fair
... protection circuit should trigger to protect the SMPS. However, even when the SMPS is in normal operation, the overload protection circuit can be triggered during the load transition. To avoid this undesired operation, the overload protection circuit is designed to trigger only after a specified tim ...
... protection circuit should trigger to protect the SMPS. However, even when the SMPS is in normal operation, the overload protection circuit can be triggered during the load transition. To avoid this undesired operation, the overload protection circuit is designed to trigger only after a specified tim ...
GS2989 - Semtech
... data outputs in a high-impedance state. When applied simultaneously, the entire device is powered-down. The GS2989 features adjustable output swing using an external bias resistor. The single-ended output swing is adjustable from 500mVpp to 1800mVpp. An output signal presence function, the OSP pin, ...
... data outputs in a high-impedance state. When applied simultaneously, the entire device is powered-down. The GS2989 features adjustable output swing using an external bias resistor. The single-ended output swing is adjustable from 500mVpp to 1800mVpp. An output signal presence function, the OSP pin, ...
multiple input and output modules 500 series
... Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. ...
... Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. ...
TMA12x Series Triac (Bidirectional Triode Thyristor) Features and Benefits Description
... Avoid locations where dust or harmful gases are present and avoid direct sunlight. ...
... Avoid locations where dust or harmful gases are present and avoid direct sunlight. ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.