
Design of High Speed Low Power 15-4 Compressor
... There are several types of static adiabatic logic circuits, namely, Complementary Energy Path Adiabatic Logic (CEPAL), Quasi Static Energy Recovery Logic (QSERL) and Quasi Static Singlephase Energy Recovery Logic (QSSERL). They are all designed to overcome the drawbacks of the previously available i ...
... There are several types of static adiabatic logic circuits, namely, Complementary Energy Path Adiabatic Logic (CEPAL), Quasi Static Energy Recovery Logic (QSERL) and Quasi Static Singlephase Energy Recovery Logic (QSSERL). They are all designed to overcome the drawbacks of the previously available i ...
OPTIMAL EFFICIENCY BASED PREDICTIVE CONTROL OF
... used with a field oriented control scheme, the induction machine is the most widely used electrical machines. The usually used direct field oriented control methods keeps rotor flux at constant rated value and ignores the machine losses. Consequently, the efficiency of the motor is poor especially w ...
... used with a field oriented control scheme, the induction machine is the most widely used electrical machines. The usually used direct field oriented control methods keeps rotor flux at constant rated value and ignores the machine losses. Consequently, the efficiency of the motor is poor especially w ...
UK1104 - CanaKit
... Channels. To set a channel to the Analog mode, first issue the CHx.SETMODE(3) command to configure the channel to the Analog mode. You can then issue the CHx.GETANALOG command to get a value of between 0 to 1023 representing a voltage of between 0 to 5V DC on the corresponding channel. It is importa ...
... Channels. To set a channel to the Analog mode, first issue the CHx.SETMODE(3) command to configure the channel to the Analog mode. You can then issue the CHx.GETANALOG command to get a value of between 0 to 1023 representing a voltage of between 0 to 5V DC on the corresponding channel. It is importa ...
Humidity Sensor Performance Characteristics
... The standard definition is the maximum difference between output measurements for a repeated loading point(s) under identical loading and environmental conditions. Honeywell uses a six sigma method called “Gauge Repeatability and Reproducibility.” The worst case repeatability is the maximum range fi ...
... The standard definition is the maximum difference between output measurements for a repeated loading point(s) under identical loading and environmental conditions. Honeywell uses a six sigma method called “Gauge Repeatability and Reproducibility.” The worst case repeatability is the maximum range fi ...
HART® Compatible Intelligent 2-wire In
... Please note, that there must be a resistance of at least 250 Ω between the connection point and the power supply for safe HART communication. The total loop resistance (load + cable) should not exceed 1100 Ω. Fig. 6. ...
... Please note, that there must be a resistance of at least 250 Ω between the connection point and the power supply for safe HART communication. The total loop resistance (load + cable) should not exceed 1100 Ω. Fig. 6. ...
Theory of Robotics Arm Control with PLC
... Arm using a programmable logic controller (PLC) along with gripper. The control system consisted of the electronic components (the PLC, a motor controller, a voltage regulator, a control pendent and a bride board circuit). The Robotic Arm works manually using potentiometers and also with the help of ...
... Arm using a programmable logic controller (PLC) along with gripper. The control system consisted of the electronic components (the PLC, a motor controller, a voltage regulator, a control pendent and a bride board circuit). The Robotic Arm works manually using potentiometers and also with the help of ...
Datasheet - STMicroelectronics
... Our smart shutdown architecture immediately turns off the output gate driver in case of overcurrent through a preferential path for the fault signal, which directly switches off the outputs. The time delay between the fault and output shutdown no longer depends on the RC values of the external netwo ...
... Our smart shutdown architecture immediately turns off the output gate driver in case of overcurrent through a preferential path for the fault signal, which directly switches off the outputs. The time delay between the fault and output shutdown no longer depends on the RC values of the external netwo ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
... wind turbines based on the doubly fed induction generator (DFIG), which have many advantages over the fixed speed induction generators or fully fed synchronous generators with full-sized converters, including variablespeed constant frequency (VSCF) operation, reduced flicker, independent control cap ...
... wind turbines based on the doubly fed induction generator (DFIG), which have many advantages over the fixed speed induction generators or fully fed synchronous generators with full-sized converters, including variablespeed constant frequency (VSCF) operation, reduced flicker, independent control cap ...
Valve Troubleshooting Guide Product Description
... reconnect all harnesses. Test the system for correct operation. If valve opens and closes as it should perform a final test of position sensor function. With valve closed disconnect motor power connection J14 & P14. Connect Meter leads to contacts in P14 as described in step 2. Squeeze the trigger o ...
... reconnect all harnesses. Test the system for correct operation. If valve opens and closes as it should perform a final test of position sensor function. With valve closed disconnect motor power connection J14 & P14. Connect Meter leads to contacts in P14 as described in step 2. Squeeze the trigger o ...
PDF
... directly connected to any output phase. In majority of the cases a three input three output converters will consist of bidirectional switches arranged in 3 rows and 3 column manner resembles to a matrix of nine bi-directional switches, henceforth the term Indirect Matrix Converter. The method of swi ...
... directly connected to any output phase. In majority of the cases a three input three output converters will consist of bidirectional switches arranged in 3 rows and 3 column manner resembles to a matrix of nine bi-directional switches, henceforth the term Indirect Matrix Converter. The method of swi ...
TE SENSOR SOLUTIONS TE CONNECTIVITY /// SENSOR SOLUTIONS
... theoretical straight line which has been fitted to the data points of an actual calibration. It expresses the maximum deviation of all data points in that calibration and is sometime expressed as a percentage of FSO, usually as a ±% error band, or % of reading. ...
... theoretical straight line which has been fitted to the data points of an actual calibration. It expresses the maximum deviation of all data points in that calibration and is sometime expressed as a percentage of FSO, usually as a ±% error band, or % of reading. ...
system component description brochure
... The Patrol 7000™ Sensor/Controller consists of a proprietary surface mount technology passive infrared (PIR) Sensor Module and advanced logic Controller circuits mounted on a small circuit board and contained in an aesthetically pleasing plastic enclosure. A. The Patrol 7000™ Sensor circuitry evalua ...
... The Patrol 7000™ Sensor/Controller consists of a proprietary surface mount technology passive infrared (PIR) Sensor Module and advanced logic Controller circuits mounted on a small circuit board and contained in an aesthetically pleasing plastic enclosure. A. The Patrol 7000™ Sensor circuitry evalua ...
Data sheet - NXP Semiconductors
... The MPXV7002 series pressure sensor operating characteristics, and internal reliability and qualification tests are based on use of dry air as the pressure media. Media, other than dry air, may have adverse effects on sensor performance and long-term reliability. Contact the factory for information ...
... The MPXV7002 series pressure sensor operating characteristics, and internal reliability and qualification tests are based on use of dry air as the pressure media. Media, other than dry air, may have adverse effects on sensor performance and long-term reliability. Contact the factory for information ...
OUTPATIENT & OFFSITE FACILITY DESIGN GUIDELINE SUMMARY
... Future capacity in outpatient facilities is relaxed to require only 10% (versus 25% in Inpatient). Outside air design conditions utilized for outpatient facilities allow the ASHRAE 1% design criteria (88°F DB/72°F WB) versus the ASHRAE 0.4% criteria we require for Inpatient facility design (90°F DB/ ...
... Future capacity in outpatient facilities is relaxed to require only 10% (versus 25% in Inpatient). Outside air design conditions utilized for outpatient facilities allow the ASHRAE 1% design criteria (88°F DB/72°F WB) versus the ASHRAE 0.4% criteria we require for Inpatient facility design (90°F DB/ ...
LMV851/LMV852/LMV854 8 MHz Low Power
... Electrical table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of the device. Limits are 100% production tested at 25°C. Limits over the operating temperature range are specified through correlations usin ...
... Electrical table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of the device. Limits are 100% production tested at 25°C. Limits over the operating temperature range are specified through correlations usin ...
INDIANA UNIVERSITY - PURDUE UNIVERSITY FORT WAYNE DEPARTMENT OF ENGINEERING
... The board will need to control a safety ignition, combustion fan, and gas valve in response to a thermostat input and circulator fan speed input. The fan speed and valve position are controlled based on parameters that WCS sets with the developed desktop application. Additionally, the board will nee ...
... The board will need to control a safety ignition, combustion fan, and gas valve in response to a thermostat input and circulator fan speed input. The fan speed and valve position are controlled based on parameters that WCS sets with the developed desktop application. Additionally, the board will nee ...
Insert Title here (Style: Paper title)
... Since in single stage amplifiers wholly expected gain is to be achieved in one stage, cascode structure would be a choice to get higher gain. Telescopic cascode and folded cascode structures are two known instances. In order to achieve high gain, as discussed, the differential telescopic topology ca ...
... Since in single stage amplifiers wholly expected gain is to be achieved in one stage, cascode structure would be a choice to get higher gain. Telescopic cascode and folded cascode structures are two known instances. In order to achieve high gain, as discussed, the differential telescopic topology ca ...
Application Note - Aeroflex Microelectronic Solutions
... Filtering for Electromagnetic Interference (EMI) In spacecraft applications, the temperature sensors are often located at some distance from the data acquisition unit, which contains the MUX, excitation source and processor, and are connected by cables. As a result, designing to meet EMI requiremen ...
... Filtering for Electromagnetic Interference (EMI) In spacecraft applications, the temperature sensors are often located at some distance from the data acquisition unit, which contains the MUX, excitation source and processor, and are connected by cables. As a result, designing to meet EMI requiremen ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.