
Safety Light Curtain 120V AC Interface - Allen
... microprocessor electronics. Type 2 sensors (testable) and/or Type 4 sensors (self-monitoring) may be operated with the 440L-M8100. The internal control system can distinguish between the different categories. Type 2 sensors are automatically cyclically tested by the 440L-M8100 every 60 minutes. The ...
... microprocessor electronics. Type 2 sensors (testable) and/or Type 4 sensors (self-monitoring) may be operated with the 440L-M8100. The internal control system can distinguish between the different categories. Type 2 sensors are automatically cyclically tested by the 440L-M8100 every 60 minutes. The ...
a 8-Bit, 50 MSPS/80 MSPS/100 MSPS 3 V A/D Converter AD9283
... The analog signal is applied differentially or single-endedly to the inputs of the AD9283. The signal is buffered and fed forward to an on-chip sample-and-hold circuit. The ADC core architecture is a bit-per-stage pipeline type converter utilizing switch capacitor techniques. The bit-per-stage block ...
... The analog signal is applied differentially or single-endedly to the inputs of the AD9283. The signal is buffered and fed forward to an on-chip sample-and-hold circuit. The ADC core architecture is a bit-per-stage pipeline type converter utilizing switch capacitor techniques. The bit-per-stage block ...
CHAPTER-6 HYDRO-TURBINE GOVERNING SYSTEM
... In digital governor, digital controller is used in turbine governing system. This is also generally PID controller. Digital control hardware running an application programme accomplishes the required control function with this system. Digital controllers used for turbine governing system are very fl ...
... In digital governor, digital controller is used in turbine governing system. This is also generally PID controller. Digital control hardware running an application programme accomplishes the required control function with this system. Digital controllers used for turbine governing system are very fl ...
DAC712 数据资料 dataSheet 下载
... input values. Monotonicity of the DAC712 is ensured over the specified temperature range to 13, 14, 15, and 16 bits for performance grades DAC712P/U, DAC712PB/UB, DAC712PK/UK, and DAC712PL/UL, respectively. ...
... input values. Monotonicity of the DAC712 is ensured over the specified temperature range to 13, 14, 15, and 16 bits for performance grades DAC712P/U, DAC712PB/UB, DAC712PK/UK, and DAC712PL/UL, respectively. ...
AD8225 英文数据手册DataSheet 下载
... CMRR of the AD8225 enables rejection of high frequency common-mode voltage (80 dB Min @ 10 kHz). As a result, higher ambient levels of noise from utility lines, industrial equipment, and other radiating sources are rejected. Extended CMV range enables the AD8225 to extract low level differential sig ...
... CMRR of the AD8225 enables rejection of high frequency common-mode voltage (80 dB Min @ 10 kHz). As a result, higher ambient levels of noise from utility lines, industrial equipment, and other radiating sources are rejected. Extended CMV range enables the AD8225 to extract low level differential sig ...
Kanthal Super electric heating elements
... without the furnace having to be cooled down. Vertically mounted elements are replaced as follows: After having located the defective element, unbolt the contacts from the busbars and remove the ceramic fiber around the upper part of the passage brick, after which the element and the passage brick m ...
... without the furnace having to be cooled down. Vertically mounted elements are replaced as follows: After having located the defective element, unbolt the contacts from the busbars and remove the ceramic fiber around the upper part of the passage brick, after which the element and the passage brick m ...
Slides - EECG Toronto - University of Toronto
... • measured 49 Gb/s input eye after 6.5-ft SMA cable (left) and equalized output eye (right) ...
... • measured 49 Gb/s input eye after 6.5-ft SMA cable (left) and equalized output eye (right) ...
MAX1098/MAX1099 10-Bit Serial-Output Temperature Sensors with 5-Channel ADC General Description
... Note 3: Conversion time is defined as the number of clock cycles (64 for voltage measurements, 125 for temperature measurements) multiplied by the internal clock period. Note 4: Individual analog input voltages cannot extend beyond the power-supply rails. Note 5: Input resistance is typically 250MΩ; ...
... Note 3: Conversion time is defined as the number of clock cycles (64 for voltage measurements, 125 for temperature measurements) multiplied by the internal clock period. Note 4: Individual analog input voltages cannot extend beyond the power-supply rails. Note 5: Input resistance is typically 250MΩ; ...
BB ADS831 datasheet
... individual application requirements and system structure. For example, communication applications often process a band of frequencies that does not include DC, whereas in imaging applications, the previously restored DC level must be maintained correctly up to the A/D converter. Features on the ADS8 ...
... individual application requirements and system structure. For example, communication applications often process a band of frequencies that does not include DC, whereas in imaging applications, the previously restored DC level must be maintained correctly up to the A/D converter. Features on the ADS8 ...
The New PL and New PL-P Series of manual and bus remote
... From the front, New PL-P models are identical to standard New PL models and retain all of their manual control features. On the dual and triple output versions, a single digital interface controls all outputs. The rear panel carries RS-232, USB and LAN (Ethernet) connectors, together with analog in ...
... From the front, New PL-P models are identical to standard New PL models and retain all of their manual control features. On the dual and triple output versions, a single digital interface controls all outputs. The rear panel carries RS-232, USB and LAN (Ethernet) connectors, together with analog in ...
Appendix I - Harding University
... Solar Power: There will be solar panels attached to the unit that will output a minimum of 25W of power to the battery circuit. Wall Outlet/ Car Outlet: The prototype will be able to run on power from a standard wall outlet in a US home or business, and a standard vehicle dashboard power source. Bat ...
... Solar Power: There will be solar panels attached to the unit that will output a minimum of 25W of power to the battery circuit. Wall Outlet/ Car Outlet: The prototype will be able to run on power from a standard wall outlet in a US home or business, and a standard vehicle dashboard power source. Bat ...
CA230008EN/ Old 230-70
... Protection and control Protection and control requirements are often unique to each customer and application. Eaton can provide complete protection and control systems designed to operate independently and/ or integrate with the customer’s protection and control scheme. Control panels can be integra ...
... Protection and control Protection and control requirements are often unique to each customer and application. Eaton can provide complete protection and control systems designed to operate independently and/ or integrate with the customer’s protection and control scheme. Control panels can be integra ...
Automotive Engineering Higher Vehicle Management Systems 9049
... or digital. The majority of electrical signals are continuous but variable quantities. A speedometer of a vehicle which has a needle that sweeps across a fixed scale provides a continuous signal that can change by small amounts, such a signal is referred to as an analogue signal. Pulse or trigger si ...
... or digital. The majority of electrical signals are continuous but variable quantities. A speedometer of a vehicle which has a needle that sweeps across a fixed scale provides a continuous signal that can change by small amounts, such a signal is referred to as an analogue signal. Pulse or trigger si ...
RT9178 - Richtek
... Aluminum electrolytics also typically have large temperature variation of capacitance value. Equally important to consider is a capacitor's ESR change with temperature: this is not an issue with ceramics, as their ESR is extremely low. However, it is very important in Tantalum and aluminum electroly ...
... Aluminum electrolytics also typically have large temperature variation of capacitance value. Equally important to consider is a capacitor's ESR change with temperature: this is not an issue with ceramics, as their ESR is extremely low. However, it is very important in Tantalum and aluminum electroly ...
LP2901-Q1 数据资料 dataSheet 下载
... Without transistor Q3, if the output voltage were allowed to drop below 0.8 V, transistor Q1 would saturate, and the output current would drop to zero. The circuit would be unable to pull low current loads down to ground or the negative supply, if used. Transistor Q3 has been included to bypass tran ...
... Without transistor Q3, if the output voltage were allowed to drop below 0.8 V, transistor Q1 would saturate, and the output current would drop to zero. The circuit would be unable to pull low current loads down to ground or the negative supply, if used. Transistor Q3 has been included to bypass tran ...
MAX3311/MAX3313 460kbps, 1µA Supply Current, RS-232-Compatible Transceivers in µMAX General Description
... Figure 1 shows the transmitter output when exiting shutdown mode. The transmitter is loaded with 3kΩ in parallel with 1000pF. The transmitter output displays no ringing or undesirable transients as the MAX3311 comes out of shutdown. Note that the transmitter is enabled only when the magnitude of V- ...
... Figure 1 shows the transmitter output when exiting shutdown mode. The transmitter is loaded with 3kΩ in parallel with 1000pF. The transmitter output displays no ringing or undesirable transients as the MAX3311 comes out of shutdown. Note that the transmitter is enabled only when the magnitude of V- ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.