A Novel Power Factor Control Scheme For High
... is obtained. In this case, the phase angle is , as indicated in Fig. 6(f) and (g), and the power factor reaches a value of 0.965, which corresponds to point P in Fig. 3. The proposed control scheme can also produce a unity power factor when the converter operates in a regeneration mode. The regenera ...
... is obtained. In this case, the phase angle is , as indicated in Fig. 6(f) and (g), and the power factor reaches a value of 0.965, which corresponds to point P in Fig. 3. The proposed control scheme can also produce a unity power factor when the converter operates in a regeneration mode. The regenera ...
AN INHERENTLY LINEAR TRANSDUCER USING THERMAL SIGMA-DELTA MODULATOR
... converters were recognized to be robust and to have high performance A/D converters. This work presents a temperature circuit meter composed of a one-bit sigma–delta modulator in which some of its block functions are performed by the thermoresistive sensor itself. This architecture idea is presented ...
... converters were recognized to be robust and to have high performance A/D converters. This work presents a temperature circuit meter composed of a one-bit sigma–delta modulator in which some of its block functions are performed by the thermoresistive sensor itself. This architecture idea is presented ...
building energy management system controllers
... The IQ®4E controller has 10 universal inputs and 6 analogue voltage outputs and is expandable up to 192 points (depending on the controller variant) by adding I/O modules. This flexibility makes it suitable for a broad range of applications. The IQ4E controller uses Ethernet and TCP/IP networking te ...
... The IQ®4E controller has 10 universal inputs and 6 analogue voltage outputs and is expandable up to 192 points (depending on the controller variant) by adding I/O modules. This flexibility makes it suitable for a broad range of applications. The IQ4E controller uses Ethernet and TCP/IP networking te ...
MAX1298/MAX1299 12-Bit Serial-Output Temperature Sensors with 5-Channel ADC General Description
... with 5-Channel ADC The MAX1298/MAX1299 implement local and remote temperature sensing with 12-bit resolution, using +5V and +3V supply voltages, respectively. Accuracy is ±1°C from 0 to +70°C, with no calibration needed. The devices feature an algorithmic switched-capacitor analog-to-digital convert ...
... with 5-Channel ADC The MAX1298/MAX1299 implement local and remote temperature sensing with 12-bit resolution, using +5V and +3V supply voltages, respectively. Accuracy is ±1°C from 0 to +70°C, with no calibration needed. The devices feature an algorithmic switched-capacitor analog-to-digital convert ...
369787 5 Amp 2-Button RF Switch SPEC
... • Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0%-90% humidity, non-condensing. Indoor use only. ...
... • Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0%-90% humidity, non-condensing. Indoor use only. ...
AD711 Precision, Low Cost, High Speed, BiFET Op Amp (Rev.E)
... The design of the AD711 gives careful attention to optimizing individual circuit components; in addition, a careful tradeoff was made: the gain bandwidth product (4 MHz) and slew rate (20 V/ms) were chosen to be high enough to provide very fast settling time but not too high to cause a significant r ...
... The design of the AD711 gives careful attention to optimizing individual circuit components; in addition, a careful tradeoff was made: the gain bandwidth product (4 MHz) and slew rate (20 V/ms) were chosen to be high enough to provide very fast settling time but not too high to cause a significant r ...
Journal
... In simulation, SZIBDC is in open-loop control for an interval t = 0–0.5 s and in closed-loop control for an interval t = 0.5–2 s. The output voltage reference is given the values of 10, 40, and 10 V for three intervals t = 0.5–1 s, t = 1–1.5 s, and t = 1.5–2 s, respectively. Fig. 13 shows the simula ...
... In simulation, SZIBDC is in open-loop control for an interval t = 0–0.5 s and in closed-loop control for an interval t = 0.5–2 s. The output voltage reference is given the values of 10, 40, and 10 V for three intervals t = 0.5–1 s, t = 1–1.5 s, and t = 1.5–2 s, respectively. Fig. 13 shows the simula ...
Datasheet - IKCM10B60HA
... HIN(U, V, W) and LIN(U, V, W) (Low side and high side control pins, Pin 7 - 12)......................................................... 5 VFO (Fault-output, Pin 14) ...................................................................................................................................... ...
... HIN(U, V, W) and LIN(U, V, W) (Low side and high side control pins, Pin 7 - 12)......................................................... 5 VFO (Fault-output, Pin 14) ...................................................................................................................................... ...
MPM3805 - Monolithic Power System
... Internal SW Pad. Connected with copper pad for thermal sink. Output Voltage Power Rail. Connect load to OUT. Output capacitor is needed. Supply Voltage. The MPM3805 operates from a +2.5V to +6V unregulated input. A decouple capacitor is needed to prevent large voltage spikes from appearing at the in ...
... Internal SW Pad. Connected with copper pad for thermal sink. Output Voltage Power Rail. Connect load to OUT. Output capacitor is needed. Supply Voltage. The MPM3805 operates from a +2.5V to +6V unregulated input. A decouple capacitor is needed to prevent large voltage spikes from appearing at the in ...
FSL146MRBN Green-Mode Fairchild Power Switch (FPS™)
... as the load current exceeding its normal level due to an unexpected abnormal event. In this situation, the protection circuit should trigger to protect the SMPS. However, in normal operation, the overload protection circuit can be triggered during load transition. To avoid this undesired operation, ...
... as the load current exceeding its normal level due to an unexpected abnormal event. In this situation, the protection circuit should trigger to protect the SMPS. However, in normal operation, the overload protection circuit can be triggered during load transition. To avoid this undesired operation, ...
Electrical safety for ships, mobile and fixed offshore platforms
... and a small measuring current will flow. This measuring current is proportional to the insulation resistance and it is then evaluated by the device's electronic system. Insulation monitors are an important part of IT systems. Therefore, they are demanded by the regulations, for example: IEC 60092-2 ...
... and a small measuring current will flow. This measuring current is proportional to the insulation resistance and it is then evaluated by the device's electronic system. Insulation monitors are an important part of IT systems. Therefore, they are demanded by the regulations, for example: IEC 60092-2 ...
High Voltage Power Supplies
... monitored via VMEbus. A complete set of software tools is available to control these units, from low level libraries to graphical application software. For detailed information see the Power Supply Control Software section. ...
... monitored via VMEbus. A complete set of software tools is available to control these units, from low level libraries to graphical application software. For detailed information see the Power Supply Control Software section. ...
RF3194 QUAD-BAND GSM POWER AMP MODULE Features
... GMSK modulation is a constant RF envelope modulation scheme which encodes information in the phase of the signal while amplitude variation is suppressed. Since no information is included in the amplitude of the signal, GMSK transmit is not sensitive to amplitude non-linearity of the power amplifier, ...
... GMSK modulation is a constant RF envelope modulation scheme which encodes information in the phase of the signal while amplitude variation is suppressed. Since no information is included in the amplitude of the signal, GMSK transmit is not sensitive to amplitude non-linearity of the power amplifier, ...
LM567/LM567C Tone Decoder (Rev. E)
... oscillator. In order to set this frequency, external components should be placed externally. The component values are given by: ...
... oscillator. In order to set this frequency, external components should be placed externally. The component values are given by: ...
- aes journals
... Vector control enables ac motors to obtain performance characteristics similar to dc machines. This control technique uses the instantaneous rotor position to calculate the required stator currents which are oriented at some specified angle with respect to the rotor. Current controllers are used to ...
... Vector control enables ac motors to obtain performance characteristics similar to dc machines. This control technique uses the instantaneous rotor position to calculate the required stator currents which are oriented at some specified angle with respect to the rotor. Current controllers are used to ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.