FSBB15CH60 Motion SPM 3 Series FSBB15CH60 Motion SPM® 3 Series
... 5. VFO output pulse width should be determined by connecting an external capacitor (CFOD) between CFOD (pin 7) and COM (pin 2). (Example : if CFOD = 33 nF, then tFO = ms (typ.)) Please refer to the 2nd note 5 for calculation method. 6. Input signal is active-HIGH type. There is a 3.3 kresistor ...
... 5. VFO output pulse width should be determined by connecting an external capacitor (CFOD) between CFOD (pin 7) and COM (pin 2). (Example : if CFOD = 33 nF, then tFO = ms (typ.)) Please refer to the 2nd note 5 for calculation method. 6. Input signal is active-HIGH type. There is a 3.3 kresistor ...
Downloaded on 2016-12-03T06:13:04Z
... The ability to handle delicate/fragile or small-scale objects is very useful, but challenging, since such materials are either very sensitive to the gripping force or too small to easily control the tiny actuation. Creating a gripper mechanism that applies exactly the right amount of force to grip s ...
... The ability to handle delicate/fragile or small-scale objects is very useful, but challenging, since such materials are either very sensitive to the gripping force or too small to easily control the tiny actuation. Creating a gripper mechanism that applies exactly the right amount of force to grip s ...
FAN73402 LED Backlight Driving Boost Switch F
... damaged due to the o ver-current coming from the input line by the negative control. This can result in the initial overshoot of the LED current. Therefore, during initial startup, the soft-start control gradually increases the duty cycle so that the output voltage can rise smoothly to control inrus ...
... damaged due to the o ver-current coming from the input line by the negative control. This can result in the initial overshoot of the LED current. Therefore, during initial startup, the soft-start control gradually increases the duty cycle so that the output voltage can rise smoothly to control inrus ...
FCPS-24F/FCPS-24FE Field Charger/Power Supply
... NAC repeater feature. In this application, one or two Notification Appliance Circuits (NAC) are connected from the main FACP NAC output(s) to the remote power supply Control Input circuits. When these Control Input circuits activate (due to reverse polarity of the NAC output), the power supply will ...
... NAC repeater feature. In this application, one or two Notification Appliance Circuits (NAC) are connected from the main FACP NAC output(s) to the remote power supply Control Input circuits. When these Control Input circuits activate (due to reverse polarity of the NAC output), the power supply will ...
MAX8556/MAX8557 4A Ultra-Low-Input-Voltage LDO
... Capacitors are required at the MAX8556/MAX8557 inputs and outputs for stable operation over the full temperature range and with load currents up to 4A. Connect 2 x 10µF capacitors between IN and GND and 2 x 10µF low equivalent-series-resistance (ESR) capacitors between OUT and GND. The input capacit ...
... Capacitors are required at the MAX8556/MAX8557 inputs and outputs for stable operation over the full temperature range and with load currents up to 4A. Connect 2 x 10µF capacitors between IN and GND and 2 x 10µF low equivalent-series-resistance (ESR) capacitors between OUT and GND. The input capacit ...
troubleshooting guide
... separations or breaks in the mercury columns at the center of the bulbs. It may CCW be necessary to warm the bulbs to fully view the mercury columns. In many cases, if a separation exists, it can be removed by the heating of the sensor causing the mercury to move to the top of the bulb. ...
... separations or breaks in the mercury columns at the center of the bulbs. It may CCW be necessary to warm the bulbs to fully view the mercury columns. In many cases, if a separation exists, it can be removed by the heating of the sensor causing the mercury to move to the top of the bulb. ...
LTM2885 - 6500VRMS Isolated RS485/RS422
... Coupled inductors and an isolation power transformer provide 6500VRMS of isolation between the line transceiver and the logic interface. This device is ideal for systems where the ground loop is broken allowing for large common mode voltage variation. Uninterrupted communication is guaranteed for co ...
... Coupled inductors and an isolation power transformer provide 6500VRMS of isolation between the line transceiver and the logic interface. This device is ideal for systems where the ground loop is broken allowing for large common mode voltage variation. Uninterrupted communication is guaranteed for co ...
LT6205/LT6206/LT6207 - Single/Dual/Quad Single Supply 3V, 100MHz Video Op Amps
... may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The inputs are protected by back-to-back diodes. If the differential input voltage exceeds 1.4V, the input current should be limited to ...
... may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The inputs are protected by back-to-back diodes. If the differential input voltage exceeds 1.4V, the input current should be limited to ...
Technical Manual DE Motion Control Systems
... flexible adjustment to the respective drive function. Thanks to the compact design, the units can be integrated into diverse applications with minimal wiring. The flexible connection options open up a broad field of application in all areas, for example in decentralized automation technology systems ...
... flexible adjustment to the respective drive function. Thanks to the compact design, the units can be integrated into diverse applications with minimal wiring. The flexible connection options open up a broad field of application in all areas, for example in decentralized automation technology systems ...
Herrtronic® MD Series
... conductivity also increases. Accordingly, the rate of boiling increases. Eventually, the rate of boiling reduces the output capacity below the “low drain threshold” before the “cycle time” initiates the fill cycle. At this point, the drain valve opens discarding the mineral laden (highly conductive) ...
... conductivity also increases. Accordingly, the rate of boiling increases. Eventually, the rate of boiling reduces the output capacity below the “low drain threshold” before the “cycle time” initiates the fill cycle. At this point, the drain valve opens discarding the mineral laden (highly conductive) ...
BORRI 7000
... Unlike its competitors, the Borri 7000 battery test is carried out during normal operations and it is not required to run the system on battery. The improved accuracy of battery performance measurement allows users to know the condition well in advance and to plan the battery maintenance with minimu ...
... Unlike its competitors, the Borri 7000 battery test is carried out during normal operations and it is not required to run the system on battery. The improved accuracy of battery performance measurement allows users to know the condition well in advance and to plan the battery maintenance with minimu ...
Real-Time High Performance Computing Platform for Smart
... parallel using high performance computing platforms in order to meet the timing requirements of real-time monitoring and control. Therefore, in order to simulate and study intelligent real-time monitoring and control techniques utilizing HPC, a platform for integrating simulation environment with co ...
... parallel using high performance computing platforms in order to meet the timing requirements of real-time monitoring and control. Therefore, in order to simulate and study intelligent real-time monitoring and control techniques utilizing HPC, a platform for integrating simulation environment with co ...
. . . Level Matching for Autosound . . . ?or Why is my system so noisy?
... its various forms) has once more raised its ugly head. Even if the manufacturer has done their engineering homework, it’s still really easy to forget some detail during installation and make even the quietest components seem noisy. Consider: • A head unit with an integral power amplifier. • An outbo ...
... its various forms) has once more raised its ugly head. Even if the manufacturer has done their engineering homework, it’s still really easy to forget some detail during installation and make even the quietest components seem noisy. Consider: • A head unit with an integral power amplifier. • An outbo ...
CMOS Hex Voltage-Level Shifter for TTL-to-CMOS or - tyro
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
QUICKTRONIC POWERSENSE T8 Universal Voltage
... voltage (0-10VDC) fluorescent controllers or compatible 2-wire power line fluorescent dimmers, making them ideal for individual office lighting or automated building applications, both in new construction and retrofit projects. For the individual office or conference room, installation can be stream ...
... voltage (0-10VDC) fluorescent controllers or compatible 2-wire power line fluorescent dimmers, making them ideal for individual office lighting or automated building applications, both in new construction and retrofit projects. For the individual office or conference room, installation can be stream ...
Diesel-Electric Propulsion Systems
... are based on the principle of speed controlled AC or DC motors driving the propeller directly or by gearing. The most reliable and low noise design is the direct drive. Electric propulsion systems are designed according to the „power station principle“. That means that under normal conditions all al ...
... are based on the principle of speed controlled AC or DC motors driving the propeller directly or by gearing. The most reliable and low noise design is the direct drive. Electric propulsion systems are designed according to the „power station principle“. That means that under normal conditions all al ...
Kinetix Motion Control
... increased. Now more than ever, it is important to find the right size products that can operate your machines around the world. The Rockwell Automation Motion Control system offers a portfolio of products with a variety of sizes and features designed to handle a wide range of applications. This scal ...
... increased. Now more than ever, it is important to find the right size products that can operate your machines around the world. The Rockwell Automation Motion Control system offers a portfolio of products with a variety of sizes and features designed to handle a wide range of applications. This scal ...
FSB32560 Motion SPM 3 Series FSB32560 Motio
... 5. VFO output pulse width should be determined by connecting an external capacitor (CFOD) between CFOD (pin 7) and COM (pin 2). (Example : if CFOD = 33 nF, then tFO = ms (typ.)) Please refer to the 2nd note 5 for calculation method. 6. Input signal is active-HIGH type. There is a 3.3 kresistor ...
... 5. VFO output pulse width should be determined by connecting an external capacitor (CFOD) between CFOD (pin 7) and COM (pin 2). (Example : if CFOD = 33 nF, then tFO = ms (typ.)) Please refer to the 2nd note 5 for calculation method. 6. Input signal is active-HIGH type. There is a 3.3 kresistor ...
UM1470
... different input voltage. A drop of efficiency at low input voltage is mainly caused by an increase in the losses in the input inrush resistor and EMI filter. Figure 6. ...
... different input voltage. A drop of efficiency at low input voltage is mainly caused by an increase in the losses in the input inrush resistor and EMI filter. Figure 6. ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.