• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Slide 1
Slide 1

... the biological molecules they may be used to label (e.g., F) even if they aren’t found there naturally.  PET isotopes can be attached to biologically interesting molecules with no or minimal impact on the behaviour of those molecules in the body. ...
A Web Based Medical Image Data Processing and Management
A Web Based Medical Image Data Processing and Management

... images has several advantages. No software is required on the viewing site, thus being cost-effective and no installation of software. This also means that the system can be used outside the hospital environment and at all time of the day. Also with the medical imaging, there are the requirements of ...
What Parents Should Know about the Safety of
What Parents Should Know about the Safety of

... and these individual images are used to build a virtual three-dimensional (3D) representation (main advantage of CBCT vs. other dental radiographs). [Figure 4] This virtual image may contain diagnostically important information that is not present in other dental images such as a bitewing or panoram ...
Automatic Localization of Target Vertebrae in Spine Surgery using
Automatic Localization of Target Vertebrae in Spine Surgery using

... Wrong site surgery results in failure to deliver proper therapy and carries profound medical, legal, and social implications. In spine surgery, the potential for wrong site surgery (viz., “wrong level” surgery, referring to the level of vertebral body) is significant due to the difficulty of localiz ...
Chapter 11
Chapter 11

...  The orbital electron re-emits the photon with its ...
Physician Simulation Order
Physician Simulation Order

... Free-breathing tx (shallow expiration and shallow inspiration breath hold scans for planning) Upper Border @ 7 cm above diaphragm or Note: Consider potential Lower Border @ 2cm below Pelvic Brim or use of non-axial treatment Slice thickness 3mm fields in determining length CT reference point midline ...
Dynamic X-ray Imaging of Iodinated Contrast-Agent
Dynamic X-ray Imaging of Iodinated Contrast-Agent

... iodine X-ray contrast media have more recently been used in order to measure renal insufficiency.2,3 Iodinated contrast agents are a reliable measure of GFR through a bolus injection followed by blood sampling. This technique is used both in laboratory rats3 and in the clinic2 because the rate of co ...
Radiation Protection Sub-Committee : re Good Practice Guidelines
Radiation Protection Sub-Committee : re Good Practice Guidelines

... Radiographic Images’ (Report EUR 16260, 1996, European Commission), but deals with the general principles associated with good imaging performance in more detail. Gives guidelines on diagnostic requirements, criteria for radiation dose to patient, and example of good radiographic technique for the f ...
1 Introduction to medical imaging
1 Introduction to medical imaging

... produces a digital image. DR uses a detector screen containing silicon detectors that produce an electrical signal when exposed to X-rays. This signal is analysed to produce a digital image. Digital images obtained by CR and DR are sent to viewing workstations for interpretation. Images may also be ...
Medical Imaging
Medical Imaging

... Photographs made with X rays are known as radiographs or ski graphs. Radiography has applications in both medicine and industry, where it is valuable for diagnosis and nondestructive testing of products for defects. Fluoroscopy is based on the same techniques, with the photographic plate replaced by ...
Digital Mammography - Cogdell Memorial Hospital
Digital Mammography - Cogdell Memorial Hospital

... generators and tubes to produce an X-ray beam. ...
2. Image Quality and artifacts in Digital Imaging
2. Image Quality and artifacts in Digital Imaging

... conventional film/screen. Appropriate collimation reduces scatter and irradiated area of patient. Use of grids improves contrast while increasing patient ...
X-ray generation, interaction and detection
X-ray generation, interaction and detection

... in eV and mostly its multiple: keV • For medical imaging, energy of photons ranges from ~10 keV to less than 150 keV. (visible light ~2eV) ...
Medical Image Processing - Image Processing and Medical Imaging
Medical Image Processing - Image Processing and Medical Imaging

... processed and given to digital-to-analog converter. Then they are fed to the TV monitor. These signals are converted to digital form using frame grabber and can be stored onto PC/AT disk. Wherever the images lack in contrast and brightness, Image Processing techniques may be used to get full details ...
RSNA 2007 - AFIIM.COM
RSNA 2007 - AFIIM.COM

... and pelvic lesions on low energy images obtained using single-source dual-energy MDCT  May enable earlier detection of small lesions and improved diagnosis of neoplastic processes ...
Advances in radiotherapy with external beam X
Advances in radiotherapy with external beam X

... To analyse respiratory motion, 4D CT imaging is used. 4D CT images can only be obtained with new-generation CT scanners. These machines have faster data acquisition and yield dynamic CT images of the thoracic region. 4D CT imaging collects time-varying scans of the lungs. The first step is to record ...
image artifacts - Montgomery College
image artifacts - Montgomery College

... Loading of more than one IP into a cassete=double exposure artifact Grid orientation so that grid lines are parallel to the plate reader’s laser scan = moire pattern. (Grids should be high frequency and grid lines need to run perpendicular to the laser scan line ...
c039-2001-cars-panorama
c039-2001-cars-panorama

... determine their relative position, and compose them by pairwise fusing them into a single panoramic view. We begin by describing the equipment setup and image capture protocol. The equipment consists of the mobile X-ray fluoroscopic unit in the operating room, a standard PC computer with a video car ...
AMIGO_Project_Week_Mallika_Winsor
AMIGO_Project_Week_Mallika_Winsor

... • Strong magnetic field is applied, causing the nuclei within the patient’s body to rotate and align – Scanner detects, records, and combines the different rotating fields into a single image – Gradients in all directions are combined to create a 3D image ...
Survey of Databases Used in Image Processing and Their
Survey of Databases Used in Image Processing and Their

... body. Unlike traditional X-rays, which highlight dense body parts, such as bones, CT provides detailed views of the body’s soft tissues, including blood vessels, muscle tissue, and organs, such as the ...
Radiology
Radiology

Design and performance characteristics of a Cone Beam CT system
Design and performance characteristics of a Cone Beam CT system

Generation of Hard Quasimonochromatic Radiation Using a Table
Generation of Hard Quasimonochromatic Radiation Using a Table

... organic materials Concern Radiation-induced damage: photon energy deposited per unit mass (dose) can cause observable changes in structure ...
- Portfoliocommunities
- Portfoliocommunities

... Computed Tomography: (limited discussion for class) CT, one of the early forms of computed radiography, uses digital technology to produce images, as slices of tissue, some as thin as a millimeter (mm) This discussion will be directed towards the process used in diagnostic radiography. Regardless of ...
Optimal Tube Potential in Pediatric CT for Radiation
Optimal Tube Potential in Pediatric CT for Radiation

... Figure 3. The change of (A) iodine contrast, (B) noise, and (C) dose-normalized iodine contrast to noise ratio (CNRD) with the tube potential (kV) for different phantom sizes. The thoracic phantom lateral width was 20 cm (Extra small), 30 cm (Small), 35 cm (Medium), 40 cm (Large), and 48 cm (Extra L ...
< 1 ... 44 45 46 47 48 49 50 51 52 ... 67 >

Fluoroscopy



Fluoroscopy /flɔrˈɒskəpi/ is an imaging technique that uses X-rays to obtain real-time moving images of the interior of an object. In its primary application of medical imaging, a fluoroscope /ˈflɔrɵˌskoʊp/ allows a physician to see the internal structure and function of a patient, so that the pumping action of the heart or the motion of swallowing, for example, can be watched. This is useful for both diagnosis and therapy and occurs in general radiology, interventional radiology, and image-guided surgery. In its simplest form, a fluoroscope consists of an X-ray source and a fluorescent screen, between which a patient is placed. However, since the 1950s most fluoroscopes have included X-ray image intensifiers and cameras as well, to improve the image's visibility and make it available on a remote display screen. For many decades fluoroscopy tended to produce live pictures that were not recorded, but since the 1960s, as technology improved, recording and playback became the norm.Fluoroscopy is similar to radiography and X-ray computed tomography (X-ray CT) in that it generates images using X-rays. The original difference was that radiography fixed still images on film whereas fluoroscopy provided live moving pictures that were not stored. However, today radiography, CT, and fluoroscopy are all digital imaging modes with image analysis software and data storage and retrieval. The use of X-rays, a form of ionizing radiation, requires the potential risks from a procedure to be carefully balanced with the benefits of the procedure to the patient. Because the patient must be exposed to a continuous source of x-rays instead of a momentary pulse, a fluoroscopy procedure generally subjects a patient to a higher absorbed dose of radiation than an ordinary (still) radiograph. Much research has been directed toward reducing radiation exposure, and recent advances in fluoroscopy technology such as digital image processing and flat panel detectors, have resulted in much lower radiation doses than former procedures.The type of fluoroscopy used in airport security (to check for hidden weapons or bombs) uses lower doses of radiation than medical fluoroscopy. It was formerly also used in retail stores in the form of shoe-fitting fluoroscopes, but such use was discontinued because it is no longer considered acceptable to use radiation exposure, however small the dose, for nonessential purposes. Only important applications such as health care, bodily safety, food safety, nondestructive testing, and scientific research meet the risk-benefit threshold for use. The reason for higher doses in medical applications is that they are more demanding about tissue contrast, and for the same reason they sometimes require contrast media.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report