• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Refresher Training for X-Ray Equipment Operators
Refresher Training for X-Ray Equipment Operators

... Again, two meter distance is based on nearest portion of body from both the tube head and nearest edge of image ...
RADIOLOGY The coursework of Radiology and Diagnostic Imaging
RADIOLOGY The coursework of Radiology and Diagnostic Imaging

... The classes are obligatory. In the case of the illness a sick leave has to be delivered. Other absences due to important reason must be documented. In the case of the absence the respective topics have to be credited. Students presenting with unjustified and uncredited absences will not be credited ...
Chapter 26
Chapter 26

... LOWER level of noise than TV cameras • This results in much HIGHER SNR than conventional TV cameras/systems • They also have NO log time or “blooming” and require NO maintenance • CCD’s can be “docked” directly to the II’s output phosphor ...
Committee Opinion, Number 656, February 2016, Guidelines
Committee Opinion, Number 656, February 2016, Guidelines

... should not be withheld if clinically indicated, but a thorough discussion of risks and benefits should take place (8). In the evaluation for acute processes such as appendicitis or small-bowel obstruction, the maternal benefit from early and accurate diagnosis may outweigh the theoretical fetal risk ...
SPR Practice Parameter for the Performance of Skeletal Scintigraphy
SPR Practice Parameter for the Performance of Skeletal Scintigraphy

... not intended, nor should they be used, to establish a legal standard of care1. For these reasons and those set forth below, the American College of Radiology and our collaborating medical specialty societies caution against the use of these documents in litigation in which the clinical decisions of ...
MAMMOMAT NovationDR Digital Mammography at
MAMMOMAT NovationDR Digital Mammography at

... depends on the characteristics of the X-ray tube. MAMMOMAT systems offer three anode/filter combinations at the tube head to perfectly match breast density and thickness: Mo/Mo, Mo/Rh and W/Rh. With dual-target Tungsten tube technology and the high mA output, MAMMOMAT NovationDR features the possibi ...
Cardiovascular Computed Tomography: Current and Future
Cardiovascular Computed Tomography: Current and Future

... Figure 2.3.  Multicycle reconstruction. Single cycle recon (a) the duration of the acquisition window (gray bar) is approximately equivalent to one-half the gantry rotation time, since this is the time required to obtain 180° of attenuation data. Multicycle recon (b) When multiple detector rows are ...
Basic CT Physics - Society for Pediatric Radiology
Basic CT Physics - Society for Pediatric Radiology

... CTDIvol Other Important things to remember about CTDIvol • The CTDIvol displayed on the scanner before the Topogram (ie. such as when you are building a protocol) will be only dependent on the technique and the phantom used (16cm or 32cm). Therefore, it will not accurately reflect the patient dose. ...
The Annotation and Image Mark-up Project
The Annotation and Image Mark-up Project

... created the cancer biomedical informatics grid (caBIG) (1). The mission of caBIG is “to develop a truly collaborative information network that accelerates the discovery of new approaches for the detection, diagnosis, treatment, and prevention of cancer, ultimately improving patient outcomes” (1). On ...
The American College of Radiology Accreditation Overview
The American College of Radiology Accreditation Overview

...  A classification of peer review finding  P and Ps for action to be taken on significant findings  Summary stats and comparisons generated for each physician by imaging modality  Summary data for each facility/practice by modality ...
effective physics education for optimizing ct image quality and dose
effective physics education for optimizing ct image quality and dose

... physics that is the foundation of the CT imaging process. There is a significant challenge in providing the medical professionals who have responsibility for and who conduct CT procedures with the appropriate knowledge of physics that can be applied to enhance the effectiveness and safety of CT. A m ...
1 Medication Injections by Medical Imaging and Radiation Therapy
1 Medication Injections by Medical Imaging and Radiation Therapy

... judgments exercised and actions taken in the course of providing those services. Acts which are within the recognized scope of practice for a given license or certification may be performed only by those individuals who possess the education and skill proficiency to perform those acts in a safe and ...
click her - Universal Consultants, Inc.
click her - Universal Consultants, Inc.

... Again, two meter distance is based on nearest portion of body from both the tube head and nearest edge of image ...
Achievable Radiation Dose Reduction with Comparable Image
Achievable Radiation Dose Reduction with Comparable Image

... potential risks of unnoticed increased patient dose because increased dose no longer leads to overexposed films. In addition, the automatic optimisation of image contrast and density renders it impossible to determine if a radiograph is overexposed or underexposed by judging its density alone. Subop ...
Respiratory Navigation Scheme for Free-Breathing 3D
Respiratory Navigation Scheme for Free-Breathing 3D

... data acquisition, since no fat suppression pulses were necessary. Data acquired within each imaging block was then prospectively accepted or rejected based on respiratory position, with an acceptance window of ±2 mm during expiration. Adult volunteers and patients were imaged on a 1.5T GE scanner (S ...
imagination at work
imagination at work

... (Data Acquisition System) The new-generation detector is created especially for the Brivo CT385. This detector is tested for thermal strength and reliability. With the new digital DAS technique, digital signal flows directly from the detector to the DAS chip, reducing the noise introduced by convent ...
Quality Control in CT, a teamwork - 2015 Joint Congress on Medical
Quality Control in CT, a teamwork - 2015 Joint Congress on Medical

... Quebec’s Guidelines on quality control and radioprotection in medical imaging A guideline composed of modules, for a progressive approach: – CT scan's quality control and radiation safety – CT scan’s acceptance and commissioning (in preparation) – Roles & responsibilities in quality control and rad ...
An Imaging Process for Early Detection of Colorectal Cancer Using
An Imaging Process for Early Detection of Colorectal Cancer Using

... for 201Tl and 191Os, respectively) is of the order of 5-10·10-7, i.e. 5-10 additional lethal cancer cases among 10,000,000 (10 million) patients aged 50 or more undergoing the screening procedure, when using the 201Tl or the 191Os source, respectively(3), (4). This risk can be compared with the risk ...
Radiation Protection Of Medical Staff
Radiation Protection Of Medical Staff

... stay very close to the patient table where the intensity of scattered radiation can be very high. For example, in a cardiology procedure when the X-ray tube is under the table, the dose rate of incident scattered radiation at the position of the operator can typically range from around 0.5 to 10 mSv ...
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

... attenuation coefficient mirroring morphological details of the organs under study. X-ray CT is a high spatial resolution and wide dynamic range imaging modality, so, even small density abnormalities can be detected [1].A CT image can be obtained within one breath hold which makes CT the modality of ...
Image Guided Radiation Therapy
Image Guided Radiation Therapy

... Tumors and organs can move up to 3 cm with respiration, so CT data for planning must target the tumor position at would be during treatment. Traditional CT images show respiratory motion as artifacts. Consequently, target volumes based on these images may end up being distorted and larger than neces ...
Slide 1
Slide 1

... This technique used to depict the body of the mandible, maxilla, and the lower one half of the maxillary sinuses in a single image. This modality is probably the most used diagnostic modality in implant dentistry. For quantitative preprosthetic implant imaging, panoramic radiography is not the most ...
Innovations in Cardiac Computed Tomography: Cone
Innovations in Cardiac Computed Tomography: Cone

... 1970s with the introduction of single-detector CT scanners that captured one slice per rotation. In 1992, the first Multi-Detector CT (MDCT) scanner was produced (CT-Twin, Elscint) capturing two slices per rotation.2 Since then, the field has advanced to the point where modern MDCT scanners are rout ...
BreAking the trend of increAsed rAdiAtion exposure to pAtients
BreAking the trend of increAsed rAdiAtion exposure to pAtients

... factor when ordering imaging examinations. By displaying the relative radiation level for a specific examination the physician is steered towards considering the choice with the lowest radiation level but with the same clinical value. ...
CT1 - hullrad Radiation Physics
CT1 - hullrad Radiation Physics

< 1 ... 39 40 41 42 43 44 45 46 47 ... 67 >

Fluoroscopy



Fluoroscopy /flɔrˈɒskəpi/ is an imaging technique that uses X-rays to obtain real-time moving images of the interior of an object. In its primary application of medical imaging, a fluoroscope /ˈflɔrɵˌskoʊp/ allows a physician to see the internal structure and function of a patient, so that the pumping action of the heart or the motion of swallowing, for example, can be watched. This is useful for both diagnosis and therapy and occurs in general radiology, interventional radiology, and image-guided surgery. In its simplest form, a fluoroscope consists of an X-ray source and a fluorescent screen, between which a patient is placed. However, since the 1950s most fluoroscopes have included X-ray image intensifiers and cameras as well, to improve the image's visibility and make it available on a remote display screen. For many decades fluoroscopy tended to produce live pictures that were not recorded, but since the 1960s, as technology improved, recording and playback became the norm.Fluoroscopy is similar to radiography and X-ray computed tomography (X-ray CT) in that it generates images using X-rays. The original difference was that radiography fixed still images on film whereas fluoroscopy provided live moving pictures that were not stored. However, today radiography, CT, and fluoroscopy are all digital imaging modes with image analysis software and data storage and retrieval. The use of X-rays, a form of ionizing radiation, requires the potential risks from a procedure to be carefully balanced with the benefits of the procedure to the patient. Because the patient must be exposed to a continuous source of x-rays instead of a momentary pulse, a fluoroscopy procedure generally subjects a patient to a higher absorbed dose of radiation than an ordinary (still) radiograph. Much research has been directed toward reducing radiation exposure, and recent advances in fluoroscopy technology such as digital image processing and flat panel detectors, have resulted in much lower radiation doses than former procedures.The type of fluoroscopy used in airport security (to check for hidden weapons or bombs) uses lower doses of radiation than medical fluoroscopy. It was formerly also used in retail stores in the form of shoe-fitting fluoroscopes, but such use was discontinued because it is no longer considered acceptable to use radiation exposure, however small the dose, for nonessential purposes. Only important applications such as health care, bodily safety, food safety, nondestructive testing, and scientific research meet the risk-benefit threshold for use. The reason for higher doses in medical applications is that they are more demanding about tissue contrast, and for the same reason they sometimes require contrast media.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report