• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... capacity and margin [4] hence may cause congestion problems [5, 6]. This occurs due to the small and large disturbances that affect the stability of operation.In addition, increasein active and reactive power also contributes to the decrease in the voltage. Voltage dropdue to uncontrolled reactive p ...
Reliability of MPPT Converter in Different Operating Modes
Reliability of MPPT Converter in Different Operating Modes

... regardless of weather conditions or load voltage. Maximum power point trackers, commonly known as MPPT, are systems that operate PV modules so that maximum power can be achieved in all radiation and temperature conditions. Fig. 3 shows a PV system includes MPPT. The DC/DC conversion process implies ...
dv/dt MOTOR PROTECTION OUTPUT FILTER Limits
dv/dt MOTOR PROTECTION OUTPUT FILTER Limits

... The KLC-Series V1k product family has been designed as an engineered solution for motor failures due to the reflected wave ...
Artificial Neural Network Based Duty Cycle Estimation for Maximum
Artificial Neural Network Based Duty Cycle Estimation for Maximum

STT13005
STT13005

... Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or other ...
Negative Impedances as Power System and Control
Negative Impedances as Power System and Control

... connection of a branch with admittance Y (or inductance L), with an ideal transformer of ratio t. The latter representation indicates that the negative shunt inductance in node H1 of Fig. 1 should not create numerical problems. Both representations, as a Π–circuit and as a cascade connection, are eq ...
AC Power Switch
AC Power Switch

... system to meet the needs of future and existing platforms requirements for safe circuit protection devices on aircraft, space platforms, automobiles and the power industry. This generation of Solid State Power Control and Distribution Technology is currently patent pending. Functional demonstrations ...
AI21212221
AI21212221

... With increasing applications of nonlinear and electronically switched devices in distribution systems and industries, powerquality (PQ) problems, such as harmonics, flicker, and imbalance have become serious concerns. In addition, lightning strikes on transmission lines, switching of capacitor banks ...
Digilent PmodHB2™ 1A H- Bridge Board Reference Manual
Digilent PmodHB2™ 1A H- Bridge Board Reference Manual

Why Choose A Line Reactor?
Why Choose A Line Reactor?

CET 3350 Scott Blvd., Bldg. 55. Unit 1
CET 3350 Scott Blvd., Bldg. 55. Unit 1

get protected
get protected

PSU-U-24V/AC-6A/8/FTA/PTC-TR-MC PSAC 08246
PSU-U-24V/AC-6A/8/FTA/PTC-TR-MC PSAC 08246

... 5. If necessary, connect device cables (alarm unit, controller, signaller, etc.) to technical outputs of the power supply: - AW output signalling the activity of the fuse (output of the LB8/24V/27V/AW fuse block). - TAMPER output signalling opening of the power supply casing. 6. In case of installat ...
Electrostatic Discharges
Electrostatic Discharges

... good for storing ICs and other computer components that may be damaged by ESD. Antistatic bags are also the best container that you can use to transport PC boards that have static-sensitive components. Grounding Straps Professional service technicians employ a number of precautionary steps when they ...
Engineering Department Electrical Section Diploma I year level in
Engineering Department Electrical Section Diploma I year level in

2SC0535T - Power Integrations
2SC0535T - Power Integrations

... inverter design covering higher power ratings. Multi-level topologies involving 1700V IGBTs with higher isolation requirements can also be easily supported by 2SC0535T2Ax-33. The 2SC0535T2Ax-33 combines a complete two-channel driver core with all components required for driving, such as an isolated ...
open saved file with Word to simulate
open saved file with Word to simulate

... Salt Lake Community College Electrical Engineering Department EE 1010 / EE2210 ...
Z35149151
Z35149151

... transmission line. All the data is collected from sending end of the system. Fault signals (voltages and currents) are collected for a cycle at 50 Hz. These signals are taken in discrete form, samples of current and samples of voltage are taken for all types of faults. This method presents a wavelet ...
Slide
Slide

Part B: Input and Output Impedance and Impedance Matching
Part B: Input and Output Impedance and Impedance Matching

Editorial Changes for 4773
Editorial Changes for 4773

... of the equipment are often faced with the challenge of installing equipment which has a lower short circuit current rating than the available fault current from the facilities. In an effort to address this challenge, the industry developed a set of descriptions of available fault current values that ...
electrical shock - SIPE Online Training
electrical shock - SIPE Online Training

... A hazardous energy control procedure shall be developed and utilized by the employer when employees are engaged in the cleaning, repairing, servicing, setting-up or adjusting of prime movers, machinery and equipment. LOCKOUT/TAGOUT ...
Topic 2 Green-Mode Power by the Milli-Watt
Topic 2 Green-Mode Power by the Milli-Watt

... for the maximum AC power during idle and no-load conditions. This work describes a power system architecture proposed to meet these new efficiency goals. The features of this architecture include a low power converter that operates in multiple modes that are determined by power demand, where each mo ...
Eaton Introduces Toggle Switches Made with EPA Registered CuVerro Antimicrobial Copper Surfaces for Healthcare Facilities 6/17/14 Power management company Eaton today announced its industry-first line of switches and wallplates made with Environmental Protection Agency (EPA) registered CuVerro antimicrobial copper surfaces will now include a toggle switch option. Read more
Eaton Introduces Toggle Switches Made with EPA Registered CuVerro Antimicrobial Copper Surfaces for Healthcare Facilities 6/17/14 Power management company Eaton today announced its industry-first line of switches and wallplates made with Environmental Protection Agency (EPA) registered CuVerro antimicrobial copper surfaces will now include a toggle switch option. Read more

... Eaton Introduces Toggle Switches Made with EPA Registered CuVerro Antimicrobial Copper Surfaces for Healthcare Facilities PEACHTREE CITY, Ga. … Power management company Eaton today announced its industry-first line of switches and wallplates made with Environmental Protection Agency (EPA) registered ...
8_2control
8_2control

... be responding to changing parameters such as light, sound, liquid levels in tanks, etc. The changing voltage levels are changed to digital numbers to be manipulated and stored in the computer. ( done by ADC) ...
< 1 ... 688 689 690 691 692 693 694 695 696 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report