• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Owner`s Manual
Owner`s Manual

... works well for both Rhythm and Solo work across many styles of music. The high range of the GAIN control (1:30 – 5:30) is all about smooth saturation. This region is most suited for single note soloing with its softer attack and more liquid response. It also has some applications for big crunch chor ...
Aalborg Universitet Function
Aalborg Universitet Function

... behavior and using the control loops to share the active and reactive power [7-10]. In recent studies, authors have tried to find equivalent models between the inverter-based generators and the synchronous machines in order to study their general stability and to improve their operation control [11- ...
04 System voltage
04 System voltage

... Voltages defined as “subtransmission” or “transmission”, however, often require the use of voltage regulators or load-tap changing transformers at the service equipment to give adequate voltage regulation. This situation typically only occurs for service voltages above 34.5 kV, however it can occur ...
An RF–DC Converter with Wide Dynamic Range Input Matching For
An RF–DC Converter with Wide Dynamic Range Input Matching For

... fire brigades use their own radio network for communication. Moreover high frequency fields are applied for radar units, in microwave ovens and for electronic article surveillance systems. At present new applications for high frequency fields in the terahertz range are developed and tested (e.g., se ...
M-ECho: A Middleware for Morphable Data-Streaming in Pervasive Systems
M-ECho: A Middleware for Morphable Data-Streaming in Pervasive Systems

... techniques in order to control energy usage at information providers vs. consumers. For the latter task, we use a localization application which is part of the enhanced player/stage framework. The application uses the adaptive monte-carlo algorithm [19] and continuously tries to localize the robot b ...
AN ELECTROMAGNETIC ENERGY SCAVENGER FROM DIRECT AIRFLOW
AN ELECTROMAGNETIC ENERGY SCAVENGER FROM DIRECT AIRFLOW

... developed [5], but such machines typically comprise complex mechanical constructions, including rotor bearings, and also require high pressure airflow for significant power output. The intricate fabrication and ruggedness dictated by these factors also confine viable implementations of rotary air-po ...
SVC for Mitigating 50 Hz Resonance of a Long 400 kV ac
SVC for Mitigating 50 Hz Resonance of a Long 400 kV ac

... line is of a novel compact tower design. The existing NamPower system has inherently a low first parallel resonance frequency. This is due to its tree-like configuration transmission network with very long radial lines operated at Extra High Voltages (220 kV and 330 kV) and remote generation. The sy ...
Folie 1
Folie 1

...  Extensive demand of space, drying out of soil, only very limited usage of line route possible  threshold value for the magnetic field (100 µT) can be exceeded  3-6 times investment costs compared to overhead lines Michael MUHR ...
GB3411111120
GB3411111120

... battery voltage is larger than a safety level (VbL*) higher than the low SOC level. The proposed power balance control method shown in Fig. 1 can be easily extended to the system with more sources. Fig. 3 shows the extension that two PV charge circuits charge the same battery, and the related operat ...
Course outline - Hibbing Community College
Course outline - Hibbing Community College

... COURSE TITLE & NUMBER: Electrical Engineering Fundamentals with Laboratory: ENGR 2061 CREDITS: 4 (Lecture 3 / Lab 1) PREREQUISITES: PHYS 2021: General Physics 2, Corequisite: MATH 2211: Differential Equations ...
BDW94CF PNP Epitaxial Silicon Transistor B D
BDW94CF PNP Epitaxial Silicon Transistor B D

... (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the ...
File
File

... DC-DC converter (chopper) is used to convert constant DC voltage into variable DC voltage. In DC-DC conversion circuits, thyristors are used as switching elements. Here thyristors must be turned off using forced commutation as they lack facility of natural commutation that is available in AC circuit ...
26 22 13 15 lv transformers tp-1s
26 22 13 15 lv transformers tp-1s

Ranger Power Master 7000 (PM7000)
Ranger Power Master 7000 (PM7000)

... Expect safety as standard during your recording. The PM7000 will save you The PM7000 is a Cat IV 600V Power Quality time and money when you solve your P.Q. problems Analyser, powered off the voltage being measured. more quickly than ever before. Multiple modes of direct & remote comms Do not miss an ...
26 22 13 15 lv transformers tp-1s
26 22 13 15 lv transformers tp-1s

... The installing contractor shall install the Siemens TP1S Super Energy Efficient K-Factor transformer per the manufacturers recommended installation practices as found in the installation, operation, and maintenance manual and comply with all applicable codes. Make sure that the transformer is level. ...
muddiest points Week 1
muddiest points Week 1

... in a circuit when they hit a resistance and how this produces the difference in potential (voltage) across the component. I thought the electrons were slowed or "held up" by the resistance, but in this case how is the current the same (in series) after the component slows the electrons? The internet ...
Conference Paper - UCF EECS - University of Central Florida
Conference Paper - UCF EECS - University of Central Florida

... in the power generated from the solar panels but also the energy from the battery to be sufficient to the output USB port. In order to optimize the performance of the power to the devices via the USB, certain mechanisms must be considered. One component that is critical to the design of the battery ...
LG3619211926
LG3619211926

... problem [5] of the output diodes is another important factor in dc/dc converters with high voltage gain. In order to overcome these problems, various topologies have been introduced. In order to increase the voltage gain, the boost converters with coupled inductors are proposed. Their voltage gains ...
PLUS+1® Controllers MC012-110 and MC012-112
PLUS+1® Controllers MC012-110 and MC012-112

... connectors, and control circuitry are designed as flexible, expandable, powerful, cost effective stand alone modules for smaller machined systems or as total machine management systems with intelligence in every node. These modules communicate with one another and other intelligent systems over a ma ...
instruction manual Installation and operating instructions for
instruction manual Installation and operating instructions for

... sealed with a flexible resin and thus protected against negative environmental influences. MaxxLuxx® -light objects are suitable for indoor and outdoor use. The requirements are met at least in accordance with IP65, up to IP 68 is possible. MaxxLuxx® light objects can be ordered individually or pre- ...
PG-Folie blau Basisversion
PG-Folie blau Basisversion

4.5 Current-voltage characteristic and power of a PEM fuel
4.5 Current-voltage characteristic and power of a PEM fuel

... When the resistance decade is set to 0 Ω (short-circuit), there are still other, very low resistances present in the circuit: the internal resistance of the ammeter of the Cobra4 Sensor-Unit Energy and the cable and module connections. As a result of these resistances, the measured characteristic cu ...
V Series Rectifier 102407
V Series Rectifier 102407

... complete round trip) must be maintained to less than 1V. ...
Ashraf Abd Elslam Ibrahim, PMP 11th Naser Khesro st. , 7th district
Ashraf Abd Elslam Ibrahim, PMP 11th Naser Khesro st. , 7th district

... Jubail Industrial College Support Facilities, KSA : The project comprises the following :  6 storey Training center building of total area about 25,275 m2  2 storey Auditorium of total area about 3,780 m2  Mosque of total area about 600 m2  Block of commercial buildings of total area about 2,600 ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... capacity and margin [4] hence may cause congestion problems [5, 6]. This occurs due to the small and large disturbances that affect the stability of operation.In addition, increasein active and reactive power also contributes to the decrease in the voltage. Voltage dropdue to uncontrolled reactive p ...
< 1 ... 687 688 689 690 691 692 693 694 695 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report