• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
(Joule) Ratings
(Joule) Ratings

... excessive current. This leads to the units being rated by maximum current it can safely conduct. MOV and SAD components typically fail due to excessive energy and most components are rated in maximum energy (Joules) or power (Watts), which can be dissipated. Power is work (energy) per unit time. By ...
uC based Whether Activated Car System
uC based Whether Activated Car System

... PWM Technique used for Anti-Braking and Anti-collision Pulse Width Modulation (PWM) is a commonly used technique for generally controlling DC power to an electrical device, made practical by modern electronic power switches. However it also finds its place in AC choppers. The average value of curren ...
Figure 7. 51.8 Volt Battery and PCM Maxwell
Figure 7. 51.8 Volt Battery and PCM Maxwell

2533 digital power meter - Advanced Test Equipment Rentals
2533 digital power meter - Advanced Test Equipment Rentals

... Air-conditioners, TV sets, VTR's, refrigerators, cleaners, power amplifiers, speakers . • Electric and machinery Motors, inverters, transformers, industrial robots . ...
STF724
STF724

... Switching times on resistive load ...
SCR Over Current Protection
SCR Over Current Protection

... employed. Fuses when used, their arc voltages are kept below 1.5 times the peak circuit voltage. For small power applications it is pointless to employ high speed fuses for circuit protection because it may cost more than the SCR. Current magnitude detection can be employed and is used in many appli ...
IEEE SM 01 Paper
IEEE SM 01 Paper

... 138 kV lines into Eagle Pass substation, the remaining 138 kV line can only support 50 MW of load at Eagle Pass substation. When this occurs, the voltage falls below 0.98 p.u. and the BTB switches to voltage control mode. Active power is reduced automatically and instantaneously to make sure the 50 ...
dc motor
dc motor

... This presentation consists of the following concepts related to the electrical machine which is used everywhere called ‘DC MOTOR’. What are electrical machines? What’s a Dc Motor? It’s basic parts. Animated working. Different Motors. Compare generator & motor diagrammatically. Summary. ...
A Low-Mu Triode Preamp - Pete Millett`s DIY Audio pages
A Low-Mu Triode Preamp - Pete Millett`s DIY Audio pages

... need very much voltage gain; in fact, some designs, called “passive preamps,” don’t have an amplifier stage at all. There is much to be said for these designsafter all, with no gain stage and only switches and passive attenuators in the signal path, the noise and distortion performance is hard to b ...
NESPOLA - putting technology to work
NESPOLA - putting technology to work

Open-circuit Test
Open-circuit Test

... • Both transformers are connected to supply such that one transformer is loaded on another. • Primaries of the two identical transformers are connected in parallel across a supply. • Secondary are connected in series such that emf's of them are opposite to each other. • Another low voltage supply is ...
Wind Power Development Project
Wind Power Development Project

... 4. What is the installed power at this moment and what do you expect for the next few years? ...
Modeling and Simulation of Three-Phase Voltage Source Inverter
Modeling and Simulation of Three-Phase Voltage Source Inverter

Low Voltage Ride-through Capability Enhancement of Doubly Fed
Low Voltage Ride-through Capability Enhancement of Doubly Fed

... RSC from the rotor to protect the converter, while the DFIG operation is changed to a squirrel cage induction generator (SCIG) operation, which absorbs reactive power from the grid. In [8], the authors proposed the use of an energy storage system (ESS) that is connected to the DC-link of DFIG. This ...
PowerPoint
PowerPoint

3-Phase Circuits
3-Phase Circuits

... Eeng224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern Mediterranean University ...
CanaryNet 100 Modular Converter
CanaryNet 100 Modular Converter

TSMS-5/8RK Satellite Multiswitch
TSMS-5/8RK Satellite Multiswitch

... receptacles, and the point where they exit from the appliance. 13. Lightning: For added protection for this product during a lightning storm, or when it is left unattended or unused for long periods of time, the unit should be disconnected from power source. 14. Power Lines: An outside antenna syste ...
FINAL POSTER
FINAL POSTER

... The input to the system will be two square waves 180º out-ofphase. A square wave was selected because it transfers the most power. Our design consists of 5 main parts: rectifier, voltage doubler, charge pump, voltage regulator, and voltage reference. Each part was designed and tested separately and ...
Parallel Circuits
Parallel Circuits

... return to the starting point. If one road is blocked, cars can still move along the other roads.  In the same way, if one branch of a parallel circuit is opened, current still flows though other branches of the circuit. ...
Generator Downsizing Request Form
Generator Downsizing Request Form

... Page 10 of 13 ...
Aalborg Universitet
Aalborg Universitet

... interface converter (e.g. an inverter in case of dc-to-ac conversion) to the power distribution system (microgrid or utility grid). The main role of this inverter is to control voltage amplitude and phase angle in order to inject the active and reactive power. In addition, compensation of power qual ...
PDF
PDF

... The Universal Source Controller – Feed Through (SC-UN-FT) line of lighting control panels provides feed-through wiring flexibility for both new and existing applications. Each Source Controller contains individual control cards that are the industry’s only “true universal” by controlling most load t ...
Payton Planar Magnetics
Payton Planar Magnetics

... Compact and high efficient power conversion is critical to the continued profitable growth and miniaturization of the telecommunication, computer, vehicle and other host industrial and military systems. The creation of any high-efficiency power supply, and especially of a Switch Mode Power Supply (S ...
AND8337/D How to Apply High Frequency DC to DC Converters in Portable
AND8337/D How to Apply High Frequency DC to DC Converters in Portable

... small solution is needed, NCP1522B is available in mDFN 0.55 mm thickness. Low profiles inductors are available on the market but their serial resistor must be carefully checked to keep good overall efficiency. Maximum output current; make sure your inductor can support the maximum current needed by ...
< 1 ... 662 663 664 665 666 667 668 669 670 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.