• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Limit Monitoring Settings
Limit Monitoring Settings

... – For a transmission branch, the percent loading will normally be slightly different at each end of the branch – This setting specifies whether to use the higher of the two values, or the lower. – Almost always set to Higher ...
Copper Development Association
Copper Development Association

Modeling of Eddy-Current Loss of Electrical Machines and Transformers
Modeling of Eddy-Current Loss of Electrical Machines and Transformers

... proposed analytical methods on a three-phase transformer, a dc motor, and an induction motor with the results of time-stepping finiteelement analysis and experiments. We provide detailed equations for the prediction of iron losses. These equations can be directly applied in the design and control of ...
Voltage Regulator TAPCON® 230
Voltage Regulator TAPCON® 230

Title Non-inductive variable reactor design and computer simulation
Title Non-inductive variable reactor design and computer simulation

Optical Mark Reading
Optical Mark Reading

... form. Lozenge marks are a later technology and have the advantage of being easier to mark and easier to eras. The large ‘bubble’ marks are legacy technology from the very early OMR machines that were so insensitive a large mark was required for reliability. In most Asian countries, a special marker ...
- aes journals
- aes journals

... density distribution in permanent magnets is based on known distribution of magnetic flux density in the airgap of BLDC motor. The eddy losses are expressed as in (17). ...
Design and Analysis of a New Dual-Stator Permanent
Design and Analysis of a New Dual-Stator Permanent

Attachment
Attachment

... transformer cover. All external devices that are connected to the top of the transformer via a gasketed connection shall have the collar continuously welded to the top of the tank. All gasketed surfaces shall be provided with gasket recess and gasket compression-limit stops. All gaskets in contact w ...
AND8460 - Implementing 12V/240W Power Supply with
AND8460 - Implementing 12V/240W Power Supply with

... The NCP1605 PFC controller features a skip mode function with thresholds that are fixed to the feedback (FB) regulation level. However, the bulk voltage ripple during skip mode would be too high for the LLC topology. Thus, in this design, the PFC skip mode is implemented via the PFC controller OVP i ...
Static Frequency Converters Contractor Questionnaire
Static Frequency Converters Contractor Questionnaire

Methodology for relative location of voltage sag source using
Methodology for relative location of voltage sag source using

... voltage sags are a power quality problem that affects both power suppliers and customers. The most severe voltage sags are caused by network faults in the power system, and they propagate through the electrical system affecting loads connected away from an event source [1]. Consequently, disturbance ...
Table of Contents - Industrial Manufacturing
Table of Contents - Industrial Manufacturing

Design and analysis of full pitch winding and concentrated stator
Design and analysis of full pitch winding and concentrated stator

... 4.5 Winding Resistance and Copper Loss of FPFRM and CSPFRM Number of turns and cross-section of the conductor is same in both the machines. However stack length and end turn overhang are different. Overhang of FPFRM is higher, which results in higher resistance and copper loss. The details of windin ...
M. Chen, K.K. Afridi, S. Chakraborty, and D.J. Perreault, “A High-Power-Density Wide-Input-Voltage-Range Isolated dc-dc Converter Having a MultiTrack Architecture,” 2015 Energy Conversion Congress and Exposition , pp. 2017-2026, Sept. 2015.
M. Chen, K.K. Afridi, S. Chakraborty, and D.J. Perreault, “A High-Power-Density Wide-Input-Voltage-Range Isolated dc-dc Converter Having a MultiTrack Architecture,” 2015 Energy Conversion Congress and Exposition , pp. 2017-2026, Sept. 2015.

... architecture may process the full system energy multiple times, imposing a penalty on efficiency. Switched-inductor circuits, switched-capacitor circuits and magnetic isolation circuits are often used as the basic building blocks of multi-stage systems [1]–[12]. They have complementary advantages an ...
Modeling of Saturation Due to Main and Leakage Flux
Modeling of Saturation Due to Main and Leakage Flux

FERROMAGNETIC COILS FOR WIRELESS POWER TRANSFER
FERROMAGNETIC COILS FOR WIRELESS POWER TRANSFER

... Power amplifier supplies voltage U1 to LR circuit, U2 is the voltage on load resistance RL, which is used for the current measurement. The device Keysight InfiniiVision MSO-X 2024A was used as the oscilloscope and function generator. LM3886 integral audio power amplifier was used to amplify function ...
PR‐PUB‐NLH‐183 (Revision 1, Jun 19‐15)  NLH 2015 Prudence Review  Page 1 of 2 Q. 
PR‐PUB‐NLH‐183 (Revision 1, Jun 19‐15)  NLH 2015 Prudence Review  Page 1 of 2 Q. 

Power and Grounding for Audio and Audio/Video
Power and Grounding for Audio and Audio/Video

2. Bulk Electric System Facilities
2. Bulk Electric System Facilities

... NHT equipment is designed to operate within the ranges of voltage, frequency, fault current and transient conditions for which it is intended to function. This consideration of operating limitations is applicable to all equipment on the BES. For considerations unique to the specific equipment, refer ...
Magnetic Saturation Effect of the Iron Core in Current Transformers
Magnetic Saturation Effect of the Iron Core in Current Transformers

... of the induced electromotive forces are similar. At 50,000 A, only the numerical analysis results could be evaluated because the experiment could not be conducted. The proposed algorithm will be useful for the design of CTs in accordance with their use and purpose while the characteristics of the el ...
Název
Název

Experiments With An induction Cooker 2
Experiments With An induction Cooker 2

... to demonstrate the Lenz law). When we than held the foil (without cooling by the pot) on the plate, it was glowing white in some places, started to melt and sparkle. It seemed the thin foil didn't load the cooker so much to switch it off by the integrated protection. Next, we placed the pot made of ...
Lecture-7 - WordPress.com
Lecture-7 - WordPress.com

Insulation coordination studies
Insulation coordination studies

... aspects like switching topology (e.g. normal operation or operating with contingencies), operating point (e.g. underexcited versus overexcited generator operation), component characteristics (e.g. remanent flux at transformer energization) and overvoltage excitation (e.g. different lightning strikes ...
< 1 ... 14 15 16 17 18 19 20 21 22 ... 183 >

Transformer



A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltages of alternating current in electric power applications.A varying current in the transformer's primary winding creates a varying magnetic flux in the transformer core and a varying magnetic field impinging on the transformer's secondary winding. This varying magnetic field at the secondary winding induces a varying electromotive force (EMF) or voltage in the secondary winding. Making use of Faraday's Law in conjunction with high magnetic permeability core properties, transformers can thus be designed to efficiently change AC voltages from one voltage level to another within power networks.Since the invention of the first constant potential transformer in 1885, transformers have become essential for the transmission, distribution, and utilization of alternating current electrical energy. A wide range of transformer designs are encountered in electronic and electric power applications. Transformers range in size from RF transformers less than a cubic centimeter in volume to units interconnecting the power grid weighing hundreds of tons.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report