LT5527 - 400MHz to 3.7GHz High Signal Level Downconverting Mixer.
... GND (Pins 9, 12): Ground. These pins are internally connected to the backside ground for improved isolation. They should be connected to the RF ground on the circuit board, although they are not intended to replace the primary grounding through the backside contact of the package. ...
... GND (Pins 9, 12): Ground. These pins are internally connected to the backside ground for improved isolation. They should be connected to the RF ground on the circuit board, although they are not intended to replace the primary grounding through the backside contact of the package. ...
UNIT – 5 Explain the different starting methods for 3
... (ii) Stator resistance starting (iii) Autotransformer starting (iv) Star-delta starting (v) Rotor resistance starting Methods (i) to (iv) are applicable to both squirrel-cage and slip ring motors. However, method (v) is applicable only to slip ring motors. In practice, any one of the first four meth ...
... (ii) Stator resistance starting (iii) Autotransformer starting (iv) Star-delta starting (v) Rotor resistance starting Methods (i) to (iv) are applicable to both squirrel-cage and slip ring motors. However, method (v) is applicable only to slip ring motors. In practice, any one of the first four meth ...
AN2446
... The STEVAL-IHT002V1 is a very low-cost evaluation board designed with the intent to replace the existing mechanical thermostat. While driving a compressor, the evaluation board is able to drive the RUN winding, replace the PTC and drive directly the START winding too. Stall rotor detection is also i ...
... The STEVAL-IHT002V1 is a very low-cost evaluation board designed with the intent to replace the existing mechanical thermostat. While driving a compressor, the evaluation board is able to drive the RUN winding, replace the PTC and drive directly the START winding too. Stall rotor detection is also i ...
INTRODUCTION TO SYSTEM PROTECTION
... ● MVA: the capacity of the transformer in terms of million volt-amps. Size can range from less than 1 MVA to 500 MVA and higher. ● Transformer rating (MVA) is determined in part by the amount of cooling employed. MVA rating increases with more cooling. OA, FOA (stage 1), FOA (stage 2) ...
... ● MVA: the capacity of the transformer in terms of million volt-amps. Size can range from less than 1 MVA to 500 MVA and higher. ● Transformer rating (MVA) is determined in part by the amount of cooling employed. MVA rating increases with more cooling. OA, FOA (stage 1), FOA (stage 2) ...
Lecture 8 - Effect of source inductance on rectifier operation
... Lecture 8 - Effect of source inductance on rectifier operation Ideal VS real rectifier with source inductance The output DC voltages of the rectifier circuits discussed so far have been found by assuming that diode currents transfer (commutate) from one diode to another instantaneously. However this ...
... Lecture 8 - Effect of source inductance on rectifier operation Ideal VS real rectifier with source inductance The output DC voltages of the rectifier circuits discussed so far have been found by assuming that diode currents transfer (commutate) from one diode to another instantaneously. However this ...
AP3988 Description A Product Line of
... The AP3988 is designed to work in constant current (CC) mode. Figure 4 shows the secondary current waveforms. ...
... The AP3988 is designed to work in constant current (CC) mode. Figure 4 shows the secondary current waveforms. ...
S270-15-2
... the fault interrupting device to isolate permanent faults and confine outages to smaller sections of line. The sectionalizer does not interrupt fault current but can be closed into a faulted line. It opens during the open interval of the backup device. For this reason, it must always be used in seri ...
... the fault interrupting device to isolate permanent faults and confine outages to smaller sections of line. The sectionalizer does not interrupt fault current but can be closed into a faulted line. It opens during the open interval of the backup device. For this reason, it must always be used in seri ...
Bidirectional VF Control of Single and 3
... The motor is energized with a single-phase AC power supply, with a capacitor connected in series with the start winding (also called an auxiliary winding) as shown in Figure 1. The value of the capacitor is chosen so that the total impedance on the auxiliary winding produces sufficient phase shift i ...
... The motor is energized with a single-phase AC power supply, with a capacitor connected in series with the start winding (also called an auxiliary winding) as shown in Figure 1. The value of the capacitor is chosen so that the total impedance on the auxiliary winding produces sufficient phase shift i ...
Design Of A Current Controlled Defibrillator
... The second, biphasic defibrillation, is becoming increasingly common since clinical studies has showed that the total amount of energy needed to defibrillate is lower in this case [3]. A lower amount of energy means that the defibrillators can be smaller since the size of the capacitor and the power ...
... The second, biphasic defibrillation, is becoming increasingly common since clinical studies has showed that the total amount of energy needed to defibrillate is lower in this case [3]. A lower amount of energy means that the defibrillators can be smaller since the size of the capacitor and the power ...
Analysis of an induction regulator for power systems
... devices lack the control speed needed for efficiency. Operating margins are forced to be large and the full potential of the transmission interconnections can not be used4. Hopefully with new regulation technology the assets can be utilized ...
... devices lack the control speed needed for efficiency. Operating margins are forced to be large and the full potential of the transmission interconnections can not be used4. Hopefully with new regulation technology the assets can be utilized ...
DISTRIBUTION TRANSFORMERS 11 kV/433
... The objective of National Electricity Policy is “Power to all by 2012”. To achive this, about 78500 MW of generation capacity and matching Transmission and Distribution systems are to be added during 11th Plan. This would entail addition of about 2.72 lakh MVA of Distribution Transformer capacity du ...
... The objective of National Electricity Policy is “Power to all by 2012”. To achive this, about 78500 MW of generation capacity and matching Transmission and Distribution systems are to be added during 11th Plan. This would entail addition of about 2.72 lakh MVA of Distribution Transformer capacity du ...
Power Transformer 115kV/12.47kV
... tap changer is on any position at, below, or above rated secondary voltage. The tap changer shall be of vacuum-diverter reactive design. The Bidder shall list in the Proposal section, the type and electrical rating of the tap changing equipment the Bidder will provide. Approved LTC mechanisms are th ...
... tap changer is on any position at, below, or above rated secondary voltage. The tap changer shall be of vacuum-diverter reactive design. The Bidder shall list in the Proposal section, the type and electrical rating of the tap changing equipment the Bidder will provide. Approved LTC mechanisms are th ...
A Power Delivery Network Aware Framework for Synthesis of 3D
... the overall performance of today’s CMPs. The PDN is required to deliver a stable power supply across the chip, which is within a desired voltage range; and tolerate large variations in load currents [1]. Multiple voltage islands (VIs) are generally used in modern CMPs to minimize the total power dis ...
... the overall performance of today’s CMPs. The PDN is required to deliver a stable power supply across the chip, which is within a desired voltage range; and tolerate large variations in load currents [1]. Multiple voltage islands (VIs) are generally used in modern CMPs to minimize the total power dis ...
0943p ERICO CRITEC in switchboard components
... links consisting of screw-clamped slide links and an earth link. Test studs General: For energy and demand meters provide rail-mounted potential test studs or plug connections next to associated current transformer links. Provide at least one set of test studs for each compartment. Accuracy classifi ...
... links consisting of screw-clamped slide links and an earth link. Test studs General: For energy and demand meters provide rail-mounted potential test studs or plug connections next to associated current transformer links. Provide at least one set of test studs for each compartment. Accuracy classifi ...
Need to fix broken links [quote author=Mike Sokol link=topic
... Since some of these terms might be foreign to your readers, let’s start with some basics: there is available on the web a very informative article by Gary Olson, Technical Support for Cummins Power, on “Paralleling Dissimilar Generators.” To summarize that article: the voltage waveform shape created ...
... Since some of these terms might be foreign to your readers, let’s start with some basics: there is available on the web a very informative article by Gary Olson, Technical Support for Cummins Power, on “Paralleling Dissimilar Generators.” To summarize that article: the voltage waveform shape created ...
Limit Monitoring Settings
... – For a transmission branch, the percent loading will normally be slightly different at each end of the branch – This setting specifies whether to use the higher of the two values, or the lower. – Almost always set to Higher ...
... – For a transmission branch, the percent loading will normally be slightly different at each end of the branch – This setting specifies whether to use the higher of the two values, or the lower. – Almost always set to Higher ...
Transformer

A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltages of alternating current in electric power applications.A varying current in the transformer's primary winding creates a varying magnetic flux in the transformer core and a varying magnetic field impinging on the transformer's secondary winding. This varying magnetic field at the secondary winding induces a varying electromotive force (EMF) or voltage in the secondary winding. Making use of Faraday's Law in conjunction with high magnetic permeability core properties, transformers can thus be designed to efficiently change AC voltages from one voltage level to another within power networks.Since the invention of the first constant potential transformer in 1885, transformers have become essential for the transmission, distribution, and utilization of alternating current electrical energy. A wide range of transformer designs are encountered in electronic and electric power applications. Transformers range in size from RF transformers less than a cubic centimeter in volume to units interconnecting the power grid weighing hundreds of tons.