* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Download Telemetry 1 I/O Interface Card User`s Guide
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Electrical substation wikipedia , lookup
Power inverter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Scattering parameters wikipedia , lookup
Schmitt trigger wikipedia , lookup
Stray voltage wikipedia , lookup
Distribution management system wikipedia , lookup
Two-port network wikipedia , lookup
Power MOSFET wikipedia , lookup
Voltage regulator wikipedia , lookup
Alternating current wikipedia , lookup
Power dividers and directional couplers wikipedia , lookup
Buck converter wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Telemetry 1
I/O Interface
User’s Guide
90001056_C
March 21, 2012
Telemetry 1 I/O Interface Card User’s Guide
Table of Contents
1. Features ................................................................................................. 3
1.1 Accessories ....................................................................................................3
2. Hardware................................................................................................ 4
2.1 Schematic........................................................................................................4
2.2 Voltage Monitoring Port (DC In).......................................................................5
2.3 Relay I/O Port..................................................................................................5
2.4 Digital-In Port ..................................................................................................5
2.5 Digital-Out Ports .............................................................................................6
3. Software.................................................................................................. 7
Page 2
Telemetry 1 I/O Interface Card User’s Guide
Telemetry 1 I/O Interface
The Telemetry 1 I/O Interface is a general purpose digital I/O interface for the TransPort WR41, WR44,
and WR44 R. Main features are:
• 1x Voltage monitoring port
• 1x Relay in/out port
• 1x Opto-isolated digital input port
• 4x Opto-isolated digital output ports
• Internal temperature monitoring
1. Features
ANT. WWAN
(Main)
ANT. WWAN
(Aux.)
ANT. WLAN
(Aux.)
ANT. WLAN
(Main)
11-58VDC
1.3A MAX
A
DC IN
MAIN
AUX.
B
RLY
A
B
IN
+
_
OUT 1
+
_
+
OUT 2
_
OUT 3
+
_
OUT 4
LAN3
ASY 0
1
2
3
LAN2
LAN1
LAN0
4
1. Voltage Monitoring Port - Measures the input voltage level and the internal temperature of the unit.
It can also be used to provide a power source for the Digital-In port.
2. Relay I/O Port - The relay will make or break a circuit depending on the state of the digital in port.
3. Digital-In Port - A sensor such as a PIR or other switch / signal input device can be connected to this
interface.
4. Digital-Out Ports - Can be programmed using Python to make or break a circuit.
All the ports are classified as SELV ports which do not use or generate voltage greater then 60VDC,
however, an isolation of a minimum of 1500Vrms is supported.
1.1 Accessories
A 14-terminal female connector is included which is designed to help ease wiring, cable management, and installation. Wires are secured to the connector via screw-down slots (see image on next
page), and the connector is affixed tightly to the TransPort unit by tapered terminals.
Recommended wire size is 16-26 AWG.
Page 3
Telemetry 1 I/O Interface Card User’s Guide
2. Hardware
The following section outlines the specifications and configuration of the Telemetry 1 I/O Interface.
2.1 Schematic
Page 4
Telemetry 1 I/O Interface Card User’s Guide
2.2 Voltage Monitoring Port (DC In)
Voltage supplied to this port is used to power an on-board micro-controller which measures the input
voltage level at this port and the internal temperature of the unit. It can also be used to provide a
power source for the “Digital-In” port.
The maximum voltage that can be used is 24VDC.
Note: Terminal ‘A’ should be connected to the common reference (typically earth / ground). The
only exception to this rule is for TransPort WR41 models that support the isolated wide range
power supply input. In this case, the polarity of the supply voltage is non-critical.
2.3 Relay I/O Port
The Relay I/O port is capable of carrying up to 5A at 30VDC resistive load. It is independent of the
Voltage Monitoring Port.
2.4 Digital-In Port
The Digital-In port has two modes of operation:
• Internal Power Mode - The voltage input from the Voltage Monitoring Port is used to “power source”
a downstream passive device, for example, a micro-switch. The maximum voltage that can be
sourced is 24VDC.
• External Power Mode - An external power source is used. The maximum voltage that can be
supplied is 24VDC.
The default mode of operation is Internal Power Mode. Schematics of how each mode operates are
shown below.
Page 5
Telemetry 1 I/O Interface Card User’s Guide
2.4.1 Hardware Configuration
The Digital-In port can be configured for either Internal or External Power Mode. Follow the steps
below to configure the device accordingly.
WARNING: Access to the inside of the unit is required. This should only be done by a qualified person in an ESD protected environment.
1. Disconnect all power connections from the unit.
2. Unscrew the screws on the bottom of the unit and remove the cover.
3. Configure the jumpers accordingly (see figure below).
4. Replace the cover and fasten with the screws.
5. Reconnect the power connections and power-up the unit.
2.5 Digital-Out Ports
The Digital-Out ports present a transistor emitter and collector output pair. The diagram on the next
page illustrates the typical application of this port. The maximum collector current is 12mA.
Page 6
Telemetry 1 I/O Interface Card User’s Guide
3. Software
The Telemetry 1 I/O Interface is configured via CLI commands. These commands can be built into
Python or Basic scripts to automate functionality, or, entered manually via the CLI or SMS.
The command ANACONDA is the main command for the interface. Its usage is as follows:
ANACONDA [-y 0|1] {-o1-4 0|1|pwm} [-r 0|1]
Frequently used commands are as follows:
ANACONDA
Current status of the interface
ANACONDA ?
Command usage
ANACONDA -y 0
ANACONDA -y 1
ANACONDA –o1 1
ANACONDA -o1 pwm
PWM 100 10
PWM 100 100
Set the relay (-y) to open (default state)
Set the relay (-y) to closed (switch something on)
Turn on digital output 1 (-o1 = digital output 1, -o2 = digital output 2, etc)
Set digital output 1 to PWM mode (PulseWave Modulation)
Set PWM frequency and ratio (light runs at 10% brightness)
Set PWM frequency and ratio (light runs at 100% brightness)
Note: The above commands are case sensitive.
Page 7
Copyright
© 2011 Digi International Inc.
All rights reserved.
Digi, Digi International, the Digi logo, a Digi International Company, the Digi web site, Digi Remote Manager,
Digi TransPort, Digi TransPort WR, and Digi TransPort WR44 are trademarks or registered trademarks of
Digi International, Inc. in the United States and other countries worldwide.
All other trademarks are the property of their respective owners.
Information in this document is subject to change without notice and does not represent a commitment on
the part of Digi International.
Digi provides this document “as is,” without warranty of any kind, either expressed or implied, including, but
not limited to, the implied warranties of fitness or merchantability for a particular purpose. Digi may make
improvements and/or changes in this manual or in the product(s) and/or the program(s) described in this
manual at any time.
This product could include technical inaccuracies or typographical errors. Changes are periodically made to
the information herein; these changes may be incorporated in new editions of the publication.
No part of this document covered by copyright may be reproduced or copied in any form or by any means
graphic, electronic, or mechanical, including photocopying, recording, taping, or information and retrieval
systems without written permission of Digi International.
Digi International
11001 Bren Road East
Minnetonka, MN 55343
952-912-3444 or 877-912-3444