• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload


... differential inputs; and external triggering. Since this is the first experiment in which you have used the oscilloscope so a little extra care is appropriate. Refer to the General Instructions for the Laboratory for additional information. A brief synopsis of the concepts and equations needed for t ...


... differential inputs; and external triggering. Since this is the first experiment in which you have used the oscilloscope so a little extra care is appropriate. Refer to the General Instructions for the Laboratory for additional information. A brief synopsis of the concepts and equations needed for t ...
Introduction to the Oscilloscope
Introduction to the Oscilloscope

... oscilloscope waits until it sees the input signal cross the voltage set by the trigger level knob, and then immediately starts a horizontal sweep. When the trigger level is set so far clockwise or counter-clockwise that the input signal never crosses the trigger level, then the oscilloscope signal w ...
450U-E Wireless Ethernet Modem Install Guide
450U-E Wireless Ethernet Modem Install Guide

... Digital Input (Transistor) ...
Introduction - Eastern Illinois University
Introduction - Eastern Illinois University

... signal has to change at the beginning of each bit, as well as in the middle of each bit. Baud rate = 10 Bit Rate = 5 => To send 100 0s, the 1 sec signal changes 200 times Figure 2-13 in textbook => Devices more elaborate. ...
Introduction - Eastern Illinois University
Introduction - Eastern Illinois University

... signal has to change at the beginning of each bit, as well as in the middle of each bit. Baud rate = 10 Bit Rate = 5 => To send 100 0s, the 1 sec signal changes 200 times Figure 2-13 in textbook => Devices more elaborate. ...
FARADAY`S LAW* Purpose of the Experiment In this experiment
FARADAY`S LAW* Purpose of the Experiment In this experiment

... very important discoveries in the early Nineteenth Century. The first, seen first in many different contexts by several scientists, but generally called Ampere’s Law, recognizes that electrical currents give rise to magnetic fields and gives the mathematical relationship between them. Thus, for exam ...
ppt
ppt

... If x(t) is an odd function, then a(m) = 0 for all m. If x(t) is an even function, then b(m)= 0 for all m. ...
ppt
ppt

... Any electromagnetic signal can be shown to consist of a collection of periodic analog signals (sine waves) at different amplitudes, frequencies, and phases The period of the total signal is equal to the period of the fundamental frequency ...
HP 4155a Guide
HP 4155a Guide

... • Before touching the parameter analyzer, think of what you want to do. • For example, which pins are what and how are they going to be sourced or measured? • Draw a diagram of the pins if necessary or obtain the datasheet • Decide on sweep parameters • What is the expected result? – If you don’t kn ...
Description of an Oscilloscope Cathode Ray Tube
Description of an Oscilloscope Cathode Ray Tube

... An oscilloscope (Figure 1) is used to test electrical devices by displaying a graph of the voltage between two points in a circuit over time. The CRT (Figure 2) displays this graph. Similar CRTs are used in radar systems, televisions, and computer monitors. This document explains to the beginning en ...
Low Frequency Receiver Circuit
Low Frequency Receiver Circuit

... Figure 4: A halfwave rectified signal from the detector enters at E and is amplified by U3A. The time constant is set by adjusting R11 and the output is buffered with the voltage follower U3B. this version it is set to 225×. The time constant is R11×C5 and is set to 5 s here. The resistor R12 provid ...
Sheet 4
Sheet 4

... impedances, voltage gain and bandwidth. 3. To trouble shoot and analyze faults in the op-amp circuits. 1.2 PRE LAB QUESTIONS 1. Determine the output voltage of each amplifier in Fig (a). ...
Slide 1
Slide 1

... Waveform y(t) sampled at a fixed rate Δt Voltage read every Δt and converted to a number If resolution is 8 bits ...
Transmission of fast signals via optical fibres Richard White Michael Daniel for
Transmission of fast signals via optical fibres Richard White Michael Daniel for

... rw@ast.leeds.ac.uk ...
SP8716/8/9 520MHz LOW CURRENT TWO-MODULUS DIVIDERS
SP8716/8/9 520MHz LOW CURRENT TWO-MODULUS DIVIDERS

... *Tested as specified in table of Electrical Characteristics ...
the oscilloscope
the oscilloscope

... An O-scope is essentially a Cathode Ray Tube (CRT) combined with appropriate circuitry so that it may be used as a voltmeter. From your lab on the CRT you may remember that a voltage applied to the horizontal plates of the CRT caused a vertical deflection of the electron beam. This deflection was pr ...
THE OSCILLOSCOPE OBJECTIVE: To become familiar with the
THE OSCILLOSCOPE OBJECTIVE: To become familiar with the

... An O-scope is essentially a Cathode Ray Tube (CRT) combined with appropriate circuitry so that it may be used as a voltmeter. From your lab on the CRT you may remember that a voltage applied to the horizontal plates of the CRT caused a vertical deflection of the electron beam. This deflection was pr ...
Oscilloscopes and their Calibration
Oscilloscopes and their Calibration

... sensitivity available on the UUT (Unit Under Test), incrementing up through the range of available attenuation ratios (i.e., Volts/Div settings) until the upper limit of the UUT is reached. The steps are repeated on any additional available vertical inputs. This process may be a throwback to earlier ...
A Switch is Pressed, So W hat??? Debouncing Light Dependent
A Switch is Pressed, So W hat??? Debouncing Light Dependent

... With no illumination, resistance can be greater than 1 MΩ (dark resistance). Resistance varies inversely proportional to light intensity. Reduces down to 10-100s ohms 100ms/10ms response time ...
PDF of the lab
PDF of the lab

... Transistor SL100 Signal generator Resistors Capacitor Digital Storage Oscilloscope & probes Connecting wires & Bread Board ...
MEASURING EMBER EM35X POWER CONSUMPTION FOR
MEASURING EMBER EM35X POWER CONSUMPTION FOR

... The first step in measuring the charge in a given ZigBee event is to configure the oscilloscope to trigger at the start of the event with enough pre-trigger time so as to see the lead-up to the start of the event on the screen. The events that we are interested in all start with the node waking from ...
Digital Data, Digital Signal
Digital Data, Digital Signal

... given noise level, higher rates means higher errors ...
Digital Voltmeter Circuit using ICL7107
Digital Voltmeter Circuit using ICL7107

... How to Operate Digital Voltmeter Circuit? The IC is powered by a dual supply of +/- 5V. Once the circuit is powered, the reference signal is set by adjusting the reference resistor. The reference voltage needs to be about half of the input voltage. The oscillating components – resistor and capacitor ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... may use the "Circuits from the Lab" in the design of your product, no other license is granted by implication or otherwise under any patents or other intellectual property by application or use of the "Circuits from the Lab". Information furnished by Analog Devices is believed to be accurate and rel ...
< 1 ... 84 85 86 87 88 89 90 91 92 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.