• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
T6703 Data Sheet
T6703 Data Sheet

... injury. In use of the product, the customer has sole responsibility for designing and implementing a solution which will ensure safe operation (including review of appropriate reliability or required redundancy, mitigation of failure modes, and/or meeting appropriate standards). The customer is resp ...
Quiz No.2 ECE 48
Quiz No.2 ECE 48

... QUIZ No. 2 ...
BM-4 - Onstate Technologies
BM-4 - Onstate Technologies

... for quick visual indication of voltage inputs or signal levels. Its small size, integrated, multi-function design makes it very useful as multi-purpose indicators. The bright LED display adds an appealing look. It is compatible with the LM391x series of bargraph display drivers for linear or VU mete ...
Understanding & Measuring Digital Audio Levels - AV-iQ
Understanding & Measuring Digital Audio Levels - AV-iQ

... Chart 1. Audio levels comparison chart showing how RMS levels relate to dBm, dBu, dBV values. (mW and dBm levels refer to 300 ohms) Chart 1 shows some sample values of RMS audio voltage levels through the typical audio range in the first column. The remaining columns show how these RMS levels relate ...
SS320-A - Kenick
SS320-A - Kenick

... is your first line of defense against incoming transient surges attempting to enter a home. It has a low profile design and can be installed on up to Class 320 (320 amp) residential and commercial single phase meter enclosures. ...
ACE3000 100 GB 10-05v2.qxd
ACE3000 100 GB 10-05v2.qxd

... An outstanding feature of this robust meter is its easy-to-read drum register that keeps the user continuously up-to-date with consumption. Cost Effective Revenue Metering Designed to provide cost-effective functionality the ACE3000 type 100/110 series combines proven metering technology with a reli ...
Ground Detection Voltmeter Page 1 of 2 Latest News from Weschler Instruments
Ground Detection Voltmeter Page 1 of 2 Latest News from Weschler Instruments

... 0, 10, 15 and 20 amps, which is constant, regardless of line voltage. The INSP-3 checks ground quality for safety and ability to support sensitive electronic equipment. Voltage under load, voltage drop, hot/neutral voltages and ground impedance are all presented on a single operator display to save ...
CM-6 - Aerionics
CM-6 - Aerionics

... The Macurco CM-6 is a low voltage, dual relay Carbon Monoxide (CO) detector, controller and transducer. The CM-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of CO and provide feedback and automatic exhaust ...
current meter and integrator - High Voltage Engineering Europa B.V.
current meter and integrator - High Voltage Engineering Europa B.V.

... The HVEE current-meter and integrator is a precision instrument designed for current- and dose measurements on particle accelerators, isotope separators, etc. The current-meter and integrator has an analog meter (60 mm scale) for current measurements and a digital readout (6 digits) for dose measure ...
VU Meter Me
VU Meter Me

... The 1x1 headers are breadboard friendly and can be soldered to the 2 mounting holes as well as to Sig + and Sig -. The mounting holes are not tied into the circuit. The + and – signals of your audio can then be connected to the module. There are 2 trimmer potentiometers that you can use to calibrate ...
262-30x Digital Panel Meter Relays
262-30x Digital Panel Meter Relays

... The 262-30 series of digital meters offer a highly accurate and stable measurement solution. Three models are available: 262-300 is for process control inputs, 262-30T for temperature inputs and 262-30A for true RMS A.C. voltage and current. ...
Digital multimeters
Digital multimeters

... The central knob has lots of positions and you must choose which one is appropriate for the measurement you want to make. If the meter is switched to 20 V DC, for example, then 20 V is the maximum voltage which can be measured, this is sometimes called 20 V fsd, where fsd is short for full scale def ...
ACTIVE LEARNING ASSIGNMENT
ACTIVE LEARNING ASSIGNMENT

... FIGURE 8 When reading AC voltage signals, a true RMS meter (such as a Fluke 87) provides a different reading than an average responding meter (such as Fluke 88).The only place this difference is important is when a reading is to be compared with a specification. (Courtesy of Fluke Corporation) ...
Integrating for a smart solution
Integrating for a smart solution

... Conlog’s new wBEC44 integrated wireless meter range provides the building block for a revolutionary new smart meter. The compact DIN rail meter is packed with features to enhance customer satisfaction, whilst providing the valuable data needed by utilities worldwide. Added to this is the ability for ...
Ny fördelningsmätare klarar alla intervall
Ny fördelningsmätare klarar alla intervall

... For the first time, it is possible to handle sub metering in an energy-intensive industry over all voltage ranges using only a single meter. This is the result of a new generation of sub meters from ABB Automation Technologies now being simultaneously launched in several European countries. The mete ...
Audio
Audio

... An audio system is calibrated when all VU meters respond in the same way to a specific audio signal—the control tone. Here the line-out of the audio mixer is calibrated with the input (recording level) of the VTR. Both VU meters show the same value. ...
AcuTrac 22 MK2 Satellite Meter
AcuTrac 22 MK2 Satellite Meter

... AcuTrac 22 MK2 Satellite Meter Two Simultaneous Signal Strength Presentations ...
70 Watt AM Shortwave Transmitter Circuit
70 Watt AM Shortwave Transmitter Circuit

... Part of the audio section; the Internal MOSFET (BUZ900/905) 100W RMS into 4 Ohms solid-state Maplin modulator/amplifier. Audio driven by a Band Pass filter; bass cut at 6dB per octave below 200Hz and then flat till 2kHz then rising at 6dB per octave to 5.5kHz then cuts to -40dB by 9 kHz. Of course ...
3-1/2D LCD Digital Panel Meter PM128/PM-188
3-1/2D LCD Digital Panel Meter PM128/PM-188

... RA=10KΩ RB=9.99MΩ 500V ...
Oxymaster II 16T
Oxymaster II 16T

... ☺ Data outputs and Data logger For the Oxygen concentration is a 4-20 mA output standard available. Other outputs are available on request. RS232 for data reading is standard. A data logger with 10000 values is included. ...
a list of common meter types - Northern Ireland Electricity Networks
a list of common meter types - Northern Ireland Electricity Networks

... Standard 24Hr Single Rate Meter (Single or Three phase) (Shop with apartment above / farm ...
Automatic Meter Reading Using GSM Network
Automatic Meter Reading Using GSM Network

... Wireless energy meter is used to monitor the electric energy consumed by customers. This meter is free from inherent defects of ordinary ferry wheel energy meters used currently, such as low accuracy, low reliability, lack of user friendliness & safety, etc. This meter is static in that it does not ...
SAE-1100 Series Carbon Monoxide (CO) Detectors
SAE-1100 Series Carbon Monoxide (CO) Detectors

... The SAE-1100 series detectors are designed to sense and transmit CO (carbon monoxide) gas levels to any compatible electronic analog control or DDC automation system for the control of ventilation equipment in industrial and commercial applications. Such information is crucial to demand controlled v ...
4CM CiTiceL®
4CM CiTiceL®

... This sensor is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the sensor and/or in ...
AtlasEng - pa0fri.com
AtlasEng - pa0fri.com

... are filtered out with simple RC filtering when it was demodulated back to audio. The result is a 'cleaner' clipped signal being finally transmitted. This increases the average output level of an audio signal from a microphone by clipping off the excessive signal peaks. By lowering the peaks in propo ...
< 1 ... 31 32 33 34 35 >

Peak programme meter



A peak programme meter (PPM) is an instrument used in professional audio for indicating the level of an audio signal.There are many different kinds of PPM. They fall into broad categories:True peak programme meter. This shows the peak level of the waveform no matter how brief its duration.Quasi peak programme meter (QPPM). This only shows the true level of the peak if it exceeds a certain duration, typically a few milliseconds. On peaks of shorter duration, it will indicate less than the true peak level. The extent of the shortfall is determined by the 'integration time'.Sample peak programme meter (SPPM). This is a PPM for digital audio which shows only peak sample values, not the true waveform peaks (which may fall between samples and be up to 3 dB higher in amplitude). It may have either a 'true' or a 'quasi' integration characteristic.Over-sampling peak programme meter. This is a sample PPM in which the signal has first been over-sampled, typically by a factor of four, to alleviate the problem with a basic sample PPM.In professional usage, where consistent level measurements are needed across an industry, audio level meters often comply with a detailed formal standard. This ensures that all meters that comply with the standard will give the same indication on a given audio signal. The principal standard for PPMs is IEC 60268-10. It describes two different quasi-PPM designs which have their roots in meters originally developed in the 1930s for the AM radio broadcasting networks of Germany (Type I) and the United Kingdom (Type II).The term Peak Programme Meter usually refers to these IEC-specified types and similar designs.PPMs were originally designed for monitoring analogue audio signals but are now also used with digital audio.PPMs do not provide effective loudness monitoring. Newer types of meter do, and there is now a push within the broadcasting industry to move away from traditional level meters such as those featured in this article to two new types: loudness meters based on EBU Tech. 3341 and oversampling true PPMs. The former would be used to standardise broadcast loudness to −23 LUFS and the latter to prevent digital clipping.