• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Analysis of dynamic behaviour of electric power systems
Analysis of dynamic behaviour of electric power systems

... The main goal of this project has been to answer the following question: what would happen in the power grid with a large amount of wind power when a three-phase, short-circuit fault has occurred in the transmission power network? The project has been a pioneering work in the area of dynamic modelli ...
MS-28 Handbook - Maintenance of Electrical Switchgear
MS-28 Handbook - Maintenance of Electrical Switchgear

... pocket and a minimum 1-1/8 inch spine pocket. To order binders from the Topeka Material Distribution Center, use PS Form 7380, MDC Supply Requisition, and enter O399A in the Postal Service Item Number (PSIN) column. If ordering by touchtone telephone, use the PSN 7510-02-000-8125 ...
two (2) www.edibon.com Catalogue
two (2) www.edibon.com Catalogue

... output: 12V. or 24 V. Outputs through either 2mm. contact terminals, or through 25 pin CENTRONICS connectors (2 outputs). LED’s voltage indicators. Robust construction. Supply: 110/220V A.C. Frequency: 50/60 Hz. FA-CO includes all the requirements for full working with any module from M1 to M99. Dim ...
A primer on USB Type-C and power delivery applications and
A primer on USB Type-C and power delivery applications and

... when one of the two CC lines is pulled down. A DFP will have both of its CC pins pulled-up with resistors Rp and a UFP will have both of its CC pins pulled-down with resistor Rd [1]. Once a DFP detects one of its CC lines being pulled down, the DFP will know that a connection has been made. 2. Orien ...
Dual-Core Intel® Xeon® Processor 5100 Series Datasheet
Dual-Core Intel® Xeon® Processor 5100 Series Datasheet

... The Dual-Core Intel® Xeon® Processor 5100 Series may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. 64-bit Intel® Xeon® processors with Intel® EM64T requires a computer syst ...
220 W LCD TV Power Supply GreenPoint® Reference Design
220 W LCD TV Power Supply GreenPoint® Reference Design

Bi-directional power converters for smart grids
Bi-directional power converters for smart grids

M-3410A-INSTRUCTION BOOK - Chipkin Automation Systems
M-3410A-INSTRUCTION BOOK - Chipkin Automation Systems

... 2,500 V pk-pk Oscillatory applied to each independent circuit to earth 2,500 V pk-pk Oscillatory applied between each independent circuit 4,000 V pk Fast Transient burst applied to each independent circuit to earth 4,000 V pk Fast Transient burst applied between each independent circuit ...
transformer loss compensation for metermen
transformer loss compensation for metermen

... expressed as a percent of the full load current. The no-load (iron) loss and percent exciting current tests are normally done on the low voltage side of the transformer because the current readings are larger, and therefore easier to read. Additionally a lower voltage power source will be easier to ...
Ultra3000 Digital Servo Drives Installation Manual
Ultra3000 Digital Servo Drives Installation Manual

... regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley® does not assume responsibility ...
Uninterruptible Power Supply 80 kVA 120 kVA Installation and
Uninterruptible Power Supply 80 kVA 120 kVA Installation and

... This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference with the equipment is operated in a commercial environment. This equipment ge ...
Dual-Core Intel® Xeon® Processor 5200 Series
Dual-Core Intel® Xeon® Processor 5200 Series

... The Dual-Core Intel® Xeon® Processor 5200 Series may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. 64-bit computing on Intel architecture requires a computer system with a ...
Easy & Econo Modules Product Brief
Easy & Econo Modules Product Brief

... Easy & Econo Modules The EasyPIM™/EasyPACK as well as the EconoPIM™/EconoPACK™ family were developed in order to have a cost effective compact design as well as simplified and reliable mounting. Therefore, Infineon offers an optimized product generation for low and medium power industrial drives. Th ...
Application Manual for Power Supply Noise Suppression
Application Manual for Power Supply Noise Suppression

2-kW Electric Power Transmission Training Systems - Lab-Volt
2-kW Electric Power Transmission Training Systems - Lab-Volt

... The 2-kW Electric Power Transmission Training System courseware consists of a Student Manual and Instructor Guide. The Student Manual contains exercises designed to present the subject matter in convenient instructional segments. In each exercise, principles and concepts are presented first, followe ...
875DP/500DP/500HV DUAL PULSE STORED ENERGY
875DP/500DP/500HV DUAL PULSE STORED ENERGY

... This instruction manual describes how to operate, maintain and service the 875DP/500DP/500HV Dual Pulse Resistance Welding Power Supply, and provides instructions relating to its SAFE use. Procedures described in this manual MUST be performed, as detailed, by QUALIFIED and TRAINED personnel. For SAF ...
EZ-PD™ CCG2 Datasheet USB Type
EZ-PD™ CCG2 Datasheet USB Type

... subsystem, which is optimized for low-power operation with extensive clock gating. It mostly uses 16-bit instructions and executes a subset of the Thumb-2 instruction set. This enables fully compatible binary upward migration of the code to higher performance processors such as the Cortex-M3 and M4, ...
P84905
P84905

... Output options include up to four (4) Class “B”, two (2) Class “A”, or two (2) Class “B” and one (1) Class “A” Notification Appliance Circuits. Additionally, an auxiliary power output can provide constant power of up to 0.075 Amps for 24 hours, or managed power up to 2.5 Amps in a non-alarm conditio ...
Solid State Relay
Solid State Relay

... ON/OFF control is a form of control where a heater is turned ON or OFF by turning an SSR ON or OFF in response to voltage output signals from a Temperature Controller. The same kind of control is also possible with an electromagnetic relay but if control where the heater is turned ON and OFF at inte ...
DMMS 300+/350/425 - Electro Industries
DMMS 300+/350/425 - Electro Industries

... The power (W) in a single phase system is: W = E • I • cosΘ E = potential, I = current, and cosΘ = phase difference between the potential and the current. Power in a 120/240V AC system is: W = (ELine 1 • ILine 1 • cosΘ) + (ELine 2 • ILine 2 • cosΘ) Phase differential between the potential and the cu ...
MOTORTRONICS™
MOTORTRONICS™

... incoming power section of the starter assembly. The maximum design voltage is 5KV for 2300 - 4160V units and 7.2KV for 6600 - 7200V units. The disconnect can be padlocked in the “Open” position. The disconnect compartment door cannot be opened while the disconnect is closed, (i.e. system power is on ...
LTC2970/LTC2970-1 - Dual I2C Power Supply Monitor and
LTC2970/LTC2970-1 - Dual I2C Power Supply Monitor and

... algorithm asserts CPIO_CFG low, the LTC2970-1 will delay disconnecting the IDACs from the power supply feedback nodes by this amount of time. Used while tracking power supplies on. ...
MASTER SPECIFICATIONS Division 26
MASTER SPECIFICATIONS Division 26

... and renovated facilities for all domestic Cleveland Clinic locations. It is be used by A/E firms in the preparation of Construction Documents for all facility types. The general purpose of each Specification is to provide minimum criteria for construction materials at Cleveland Clinic facilities reg ...
XG-XTR850-1500-1700 Operation Manual M370430
XG-XTR850-1500-1700 Operation Manual M370430

... WARNING: Limitations on use The XG Family Programmable DC Power Supply is not intended for use in connection with life support systems or other medical equipment or devices. ...
Breakers, Relays, and Disconnects
Breakers, Relays, and Disconnects

... Interrupt the current flow quickly enough to prevent or minimize damage to the component.  Interrupt current flow quickly enough to contain any damage to that component alone, as well as protect the rest of the electrical system. Choices include fuses, overloads, or a protective relay to trip the m ...
< 1 2 3 4 5 6 7 8 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report