• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
INSTRUCTION MANUAL Sunshine Duration Meter MS-093
INSTRUCTION MANUAL Sunshine Duration Meter MS-093

... This mirror has diffuse characteristics only in the declination direction, thus it does not affect the output signal by the declination changes. Without making any adjustments with mirror to the declination changes (± 23.5℃), the light is directed to the center of the sensor; therefore, it does not ...
60708-124 LARGE PTO -WInpower
60708-124 LARGE PTO -WInpower

... WP135PTOS, WP145PTOT and the WP150PTOS you will connect your power output leads directly to the mainline circuit breaker.) To aid in determining how much load can be applied to the generator, and how it should be distributed among the generator output receptacles, the following formulas may be usefu ...
Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
Document
Document

... Diodes must be able to withstand a reverse voltage when they are reverse biased. This is called the peak inverse voltage (PIV). The PIV depends on the type of rectifier circuit and the maximum secondary voltage. For example, in a full-wave circuit, if one diode is conducting (assuming 0 V drop), the ...
A Comparison of Circuit Breakers and Fuses for
A Comparison of Circuit Breakers and Fuses for

... significant equipment and facility damage if not cleared from the system quickly, phase overcurrent protective devices may not respond quickly to the lower fault levels—if they detect the fault at all. For example, an 800 A ground fault might simply appear as an unbalanced load to a 4000 A fuse or c ...
IF 1545 Revision 1
IF 1545 Revision 1

... may generate dangerous voltages. Although CHCA has incorporated every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA
TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA

... critical load at all time with no switching during a power outage, or Green mode through static switch for better efficiency with fast transfer time (less than 2 milliseconds) and compatibility with all type of lightings. The system's automatic-overload and short circuit protection of the inverter i ...
part 2 products - GE Grid Solutions
part 2 products - GE Grid Solutions

... "UPS", to provide continuous, regulated AC power to critical loads under normal and abnormal conditions, including loss of the utility AC power. ...
LIMEL Integrated Laboratory for Electrical Machines Laboratory structure
LIMEL Integrated Laboratory for Electrical Machines Laboratory structure

... LIMEL, Electrical Machines Integrated Laboratory is a set of different elements that can be interconnected to form a complete learning and teaching center. From the minimum configuration to the most advanced one (always depending on the customer’s choice) EDIBON offers a means of learning electric f ...
Subject: Power Electronics & Industrial Control Content Developed by :
Subject: Power Electronics & Industrial Control Content Developed by :

... only by the stray wiring inductance. Also in high frequency switching circuits (e.g, SMPS) if the time period t4 is comparable to switching cycle qualitative modification to the circuit behavior is possible. Towards the end of the reverse recovery period if the reverse current falls too sharply, (lo ...
External Reactive Power Compensation of Permanent Magnet
External Reactive Power Compensation of Permanent Magnet

... The first wind turbine to generate electricity was built by American scientist and businessman Charles Brush in 1888. It was 17 meters tall with 144 cedar rotor blades, and it had a capacity of 12 kilowatts. Later, in the year 1891, Danish inventor Poul La Cour discovered that faster rotating wind t ...
CS EU Operation and installation manual SOLIVIA CS EU G3
CS EU Operation and installation manual SOLIVIA CS EU G3

... MPP is achieved through the software. The central inverter easily changes its operating point again and again and compares the new output with that of the previous operating point. The software then decides whether the new operating point is better than the old one. This procedure is also known as t ...
Table of Contents - UCF EECS - University of Central Florida
Table of Contents - UCF EECS - University of Central Florida

... The power company may have realized that one of the transformers is not responding appropriately in a given sector, but a problem they face is they do not have any means to figure out exactly where to send their service men. This means that the elderly couple could have to wait hours for electricit ...
Chapter 7 Power Transformer Design
Chapter 7 Power Transformer Design

... Because of their significance, the area product, Ap, and core geometry, Kg, are treated extensively in this book. A great deal of other information is also presented for the convenience of the designer. Much of the material is in tabular form to assist the designer in making trade-offs, best-suited ...
Time Varying Harmonic Currents from Large Penetration Electronic
Time Varying Harmonic Currents from Large Penetration Electronic

... The measurement results have been processed in analogy with laser printer. Figure 14 shows voltage and current waveshapes as recorded for stand-by and printing operation stages. Figure 15, Figure 16 and Figure 17 are reported for illustrating the harmonic currents magnitude spectrum variability for ...
CYCLADES PM IPDU Installer/User Guide ®
CYCLADES PM IPDU Installer/User Guide ®

... pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordanc ...
Power Generation Controls
Power Generation Controls

... mode of operation the generators will softly unload until their combined output is less than 50kW (adjustable) for 10 seconds. At this time the generator breakers will open and the engines will cooldown and then shutdown. h. If there is a utility outage during the Parallel with Utility mode of opera ...
Third Rail Fuse Link Application Guide
Third Rail Fuse Link Application Guide

... The available supply current on third rail systems can be extremely high when close to the substations. At long distances from the substations the circuit time constant caused by the high inductance steel rail will be very high and the available current may be relatively low. Fuse links must be sele ...
ADTS - MS Word Document
ADTS - MS Word Document

... both sets of main contacts from being closed at the same time. Main operators which include overcurrent disconnect devices OR do not include electrical and mechanical interlocks will not be accepted. B. All transfer switch sizes shall use only one type of main operator for ease of maintenance and co ...
CMPWR150 - 500 mA/3.3 V SmartOR TM Power Regulator
CMPWR150 - 500 mA/3.3 V SmartOR TM Power Regulator

... disabled. Internal loading on this pin is typically 1.0 mA when the regulator is enabled, which decreases to 0.15 mA whenever the regulator is disabled. If VCC falls below the voltage on the VOUT pin the VCC loading will further decrease to only a few microamperes. During a VCC power up sequence, th ...
Lock-In Specification - Crucial Power Products
Lock-In Specification - Crucial Power Products

... The switch can transfer the load from reserve to inverter or from inverter to reserve without losing power at the output. Therefore, it is a very important portion of a UPS. Detection circuitry is added to the control circuit to achieve zero dead time transfer. Extra detection logic is employed to c ...
4.4 Essential Electrical System Requirements
4.4 Essential Electrical System Requirements

Kuhlman Electric Corporation
Kuhlman Electric Corporation

... accordance with the highest engineering standards to provide reliable and economical service for a wide variety of utility and industrial applications. Designs take full advantage of improved core, coil and insulation materials, new manufacturing techniques and processes, and the latest advances in ...
Deploying Brocade FastIron-based PoE and PoE+ Solutions in the
Deploying Brocade FastIron-based PoE and PoE+ Solutions in the

... distributed enterprises with changing business needs. FastIron WS switches are available in 24- and 48port 10/100 or 10/100/1000 Mbps models, with or without IEEE 802.3af PoE, for enterprise edge networking, security, and unified communication needs. Featuring standards-based PoE, the FastIron WS de ...
AN77900 - PSoC® 3 and PSoC 5LP Low
AN77900 - PSoC® 3 and PSoC 5LP Low

< 1 ... 27 28 29 30 31 32 33 34 35 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.