• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Transformer Modelling Guide
Transformer Modelling Guide

Advanced Diagnostics Manual
Advanced Diagnostics Manual

Instruction manual 850 Feeder Protection System
Instruction manual 850 Feeder Protection System

... © 2013 GE Multilin Incorporated. All rights reserved. GE Multilin 850 Feeder Protection System instruction manual for revision 1.1x. 850 Feeder Protection System, EnerVista, EnerVista Launchpad, and EnerVista 8 Series Setup are registered trademarks of GE Multilin Inc. The contents of this manual a ...
GEK-119651C - GE Grid Solutions
GEK-119651C - GE Grid Solutions

... GE publication code: 1601-0651-A4 (GEK-119651C) ...
pdf - at www.arxiv.org.
pdf - at www.arxiv.org.

... such that each column of [TI ] and [TV ] corresponds to a particular mode, and for which the entries describe the relative (i.e., with respect to the modal quantities) currents and voltages on each conductor for that mode. The TL wave equations for propagation along z in the terminal domain can be e ...
c62 series definitions
c62 series definitions

... A discrete surge protective device involving a single specific technology and intended to be installed as a component within a surge protector or as a component housed within the equipment to be protected. NOTE-- Examples are “component air gap surge-protective device”, “component gas tube surge-pro ...
Service Manual - Fluke Calibration
Service Manual - Fluke Calibration

Advanced Energy® AE 500 Inverter
Advanced Energy® AE 500 Inverter

EIB/KNX IP Router mit Power over Ethernet (PoE)
EIB/KNX IP Router mit Power over Ethernet (PoE)

... The Power over Ethernet supply is standardized acc. to Standard PoE (IEEE 802.3af) and integrated via RJ45. We can recommend a PoE Ethernet Switch from Netgear, e.g. FS108P. The device disposes of 8 ports, four of which are equipped with Power over Ethernet (IEEE802.3af, 48 VDC). The IP router for e ...
(IV-6-6) Electrical Installations
(IV-6-6) Electrical Installations

... Industrial Services ...
SIMODRIVE 611 Drive Converter
SIMODRIVE 611 Drive Converter

MAX13046E/MAX13047E Single- and Dual-Bidirectional Low-Level Translator General Description
MAX13046E/MAX13047E Single- and Dual-Bidirectional Low-Level Translator General Description

... either direction (VL↔VCC) on any single data line. The MAX13046E/MAX13047E accept VL from +1.1V to the minimum of either +3.6V or (VCC + 0.3V), and VCC from +1.65V to +5.5V, making these devices ideal for data transfer between low-voltage ASICs/PLDs and higher voltage systems. The MAX13046E/MAX13047 ...
NEM Interconnection Handbook
NEM Interconnection Handbook

... must be completed before SCE will issue written authorization to interconnect in the form of a Permission to Operate (PTO) letter. The purpose of the technical review is to facilitate the safe interconnection of eligible NEM generators to the SCE electrical Distribution System. To ensure the generat ...
hvdc transmission system for remote alaska applications
hvdc transmission system for remote alaska applications

Advanced Energy® AE 500TX Inverter
Advanced Energy® AE 500TX Inverter

PSPICE
PSPICE

... We will see how to display other values shortly. ...
PSPICE Lecture #1 - Faculty Websites
PSPICE Lecture #1 - Faculty Websites

... We will see how to display other values shortly. ...
gesis ELECTRONIC - Wieland Electric
gesis ELECTRONIC - Wieland Electric

PowerPoint 演示文稿
PowerPoint 演示文稿

... Even when in a shipyard for repair, a shore supply will usually be taken. ...
64-0007 Rev B - Magnum Dimensions
64-0007 Rev B - Magnum Dimensions

Ozone Generator and Ozone PCB Tests and Fault Troubleshooting
Ozone Generator and Ozone PCB Tests and Fault Troubleshooting

... Please ensure that all internal tubes are connected before carrying out the ozone tests to ensure the system is gas tight. When the ozone test is complete, go to the Simulate menu, set the MFC flow to 40 l/hr and purge the lines with oxygen gas for at least 2 minutes. This will ensure than any trace ...
CSR-2-R17 Metal Clad
CSR-2-R17 Metal Clad

... 1.8. REQUIRED SUBMITTAL: A short-circuit and coordination study shall be prepared by the Customer and submitted to BGE for review and approval. The coordination study shall indicate the ampere rating and time-current characteristics of the proposed power or electronic fuses on the outgoing feeders, ...
JEDEC STANDARD
JEDEC STANDARD

... ESD-protected workstation: A work position with materials and equipment that limit electrostatic potential. ESD-protective packaging: A packaging system that provides electrostatic protection and limits triboelectric charging to levels that do not result in device damage. ESD-protective worksurface: ...
gesis ELECTRONIC - Wieland Electric Inc.
gesis ELECTRONIC - Wieland Electric Inc.

... gesis® FLEX power supply module 3-phase incl. gesis® plugs System gesis® FLEX - The 3-phase power supply module with flat surface mounted housing, which can be fitted on DIN rails for decentralized installation, allows a mains supply separate from the base module within a modular system. This means ...
Jva Zm20 Manual
Jva Zm20 Manual

< 1 2 3 4 5 6 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report