• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
VMX Series Manual
VMX Series Manual

PowerHub 2 Power Distribution Unit
PowerHub 2 Power Distribution Unit

... other safety hazards. Following these safety instructions is extremely important to avoid possible injury or death. DANGER! This symbol is used throughout this manual to indicate the presence of high voltages, representing a hazard for electric shock, burn or explosion. Follow the instructions caref ...
S280-79-2
S280-79-2

... Every time the Form 5 software is opened, a default database, “untitled”, is opened. This should be the only database that is ever open when communication with a control is initiated. When communication is established, the Form 5 sends and overwrites the hardware settings in the open database. This ...
Aalborg Universitet High Voltage Power Converter for Large Wind Turbine Sztykiel, Michal
Aalborg Universitet High Voltage Power Converter for Large Wind Turbine Sztykiel, Michal

... evaluated, where voltage increase is dictated by the removal of the step-up transformer. As a result, an entire wind turbine electrical system operates at 20 kV level - identical as for the collector distribution network. Medium voltage operation allows the converter unit along with the filter to be ...
Instruction Bulletin DIGITRIP® RMS Trip Units
Instruction Bulletin DIGITRIP® RMS Trip Units

Electrician Apprenticeship Course Outline
Electrician Apprenticeship Course Outline

... training- in both on-the- job training and technical training. The board also recognizes that safety awareness and education begins on the first day of on-the-job training and thereby is the initial and ongoing responsibility of the employer and the apprentice as required under workplace health and ...
Considerations for Using Harmonic Blocking and Harmonic
Considerations for Using Harmonic Blocking and Harmonic



... off-site ac power for the LNP 1 and LNP 2 via a common switchyard. The connections of LNP 1, LNP 2, the switchyard, and the 500 kV transmission system are shown in Figures 8.2-201 and 8.2-202 respectively. The common 500 kV/230 kV switchyard provides a 500 kV circuit feed to the main step-up transfo ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems

... Category I Safeguards Building (SB), Essential Service Water Pump Building (ESWPB) or Diesel Generator Building, which provides physical separation from the redundant equipment. The EPSS Class 1E switchgear buses, LCs, MCCs, distribution transformers and other Class 1E components meet the Seismic Ca ...
Medical Equipment Maintenance Manual
Medical Equipment Maintenance Manual

... a brief description of the function and working of the equipment a line drawing of the equipment and its parts a troubleshooting checklist for common problems and their solution a maintenance checklist for daily and weekly tasks The checklists are on separate pages so they can be copied and laminate ...
MS-5012 - Fire
MS-5012 - Fire

... A fire alarm system will not operate without any electrical power. If AC power fails, the system will operate from standby batteries only for a specified time and only if the batteries have been properly maintained and replaced regularly. Equipment used in the system may not be technically compatibl ...
Conext Core XC Series Grid Tie Photovoltaic Inverter: Operation
Conext Core XC Series Grid Tie Photovoltaic Inverter: Operation

... ____________________________ ...
CHAPTER QUIZ
CHAPTER QUIZ

... By James D. Halderman ...
commercial electric Water HeaterS
commercial electric Water HeaterS

... 1 DO NOT energize the branch circuit supplying power to the water heater or test the water heater electrical system before the water heater is completely filled with water. Read the start up procedures in the Instruction Manual that came with the water heater. 2 Be sure to turn off power and use a l ...
ECMA-287 1st edition
ECMA-287 1st edition

IU-JEEE
IU-JEEE

Geomagnetically Induced Current
Geomagnetically Induced Current

... • Geomagnetic disturbances (GMD) occur when particles  discharged from the sun during solar storms interact  with the earth's magnetic field. • Power systems are vulnerable to geospatial variation in  dc voltage caused by GMD. • Geomagnetically induced currents (GIC) flow through  circuits formed by ...
197 RM1 XA LT3 S LR97D LT47 LUTM p0BL LTM R
197 RM1 XA LT3 S LR97D LT47 LUTM p0BL LTM R

... TeSys d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, long starting times and prolonged stalling of the motor. 1 Adjustment dial Ir. 2 Test button. Operation of the Test button allows: - checking of control circuit wiring, - simulat ...
Information required to Assess the Reliability of a RAS Guideline
Information required to Assess the Reliability of a RAS Guideline

VPhase VX1 Installation Instructions - E
VPhase VX1 Installation Instructions - E

KFE10001-E
KFE10001-E

... Figure 8. Being spring biased, the pawl engages the ratchet rod at the bottom of its stroke, raising the rod approximately 7,9-mm (5/16-in.). At the top of its stroke, the pawl disengages from the ratchet rod, returning to its starting position as the recloser closes. The count is registered by a pi ...
Electric Service Requirements - Benton Rural Electric Association
Electric Service Requirements - Benton Rural Electric Association

TPS40400 3-V to 20-V PMBus Synchronous
TPS40400 3-V to 20-V PMBus Synchronous

... occurs by sensing the voltage drop across the inductor or across a resistor placed in series with the inductor. A PMBus programmable threshold is compared to this voltage and is used to detect overcurrent. When the overcurrent threshold is reached, a pulse by pulse current limit scheme is used to li ...
MN202001EN/ Old S210-12-1
MN202001EN/ Old S210-12-1

... • Is trained in industry-accepted high and low-voltage safe operating practices and procedures. • Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. • Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses ...
N.A. Sales Training Telcom Overview - ESET-Wiki
N.A. Sales Training Telcom Overview - ESET-Wiki

... Protection Application: The power bus of the battery pack should be protected against an overcurrent runaway condition of the Li-ion cell, as well as from ESD. The control line (e.g. SMBus, I2C, etc.) may also need to be protected against ESD. These are all low voltage (<6VDC) circuits. Solution Des ...
< 1 ... 6 7 8 9 10 11 12 13 14 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report