• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Adapted from:DT Hall:Practical Marine Electrical Knowledge
Adapted from:DT Hall:Practical Marine Electrical Knowledge

...  The insulation resistance is measured by the equipment known as megger, which is a high resistance meter with a test voltage of about 500 volts dc. The 500 V is produced with the help of a hand driven generator or with the help of batteries and electronic voltage charger.  The 500 V test charge i ...
Fire Alarm System - Shoreline Fire Department
Fire Alarm System - Shoreline Fire Department

... Work Order # ...


... system of large AC electric machines before an unexpected in-service failure occurs. Unlike the pass or fail of a DC or AC hi-pot test, the DC ramp test gives diagnostic information and often can be stopped before a failure occurs. Unlike a stepped voltage test, the ramped voltage test enables the u ...
Manufactured Home Cableset
Manufactured Home Cableset

Electrical Appliances Testing Policy
Electrical Appliances Testing Policy

... (1-year frequency of testing) The term “Educational Establishments” will not be applied to the University of Auckland where conditions of this Appendix are complied with. Accordingly, re-scheduling (exemption1) and amended categories 2, 3, 4, & 5, of this appendix may be adopted. Otherwise all parts ...
File
File

Science (done) > Mrs Potts > 11A5 Physics
Science (done) > Mrs Potts > 11A5 Physics

... How does earthing work? ...
RS-485 Data Communication Tester
RS-485 Data Communication Tester

... Hong Kong Chanel Building Macy's Holiday Display San Francisco ...
elektra plus, end of line test system for automotive
elektra plus, end of line test system for automotive

For predictive maintenance, grab a 5 kV tester
For predictive maintenance, grab a 5 kV tester

... the amount of resistance present. For example, if 1000 V is applied and 1 mA measured, then R=1 MΩ. If only oneFor general insulation testing you can’t beat a handheld 1 kV hundredth of that current, insulation resistance tester (IRT) 10 uA, is measured, then also known as a megohmmeter. R=100 MΩ. T ...
Electrical safety (word doc)
Electrical safety (word doc)

... and built to a relevant British Standard Establish a system for correctly wiring and fusing new appliances before use Ensure sufficient sockets are available before purchasing extra electrical equipment If extension leads or multi- blocks must be used ensure they are correctly fused, not overloaded ...
Laboratory Electrical Safety - Tufts Public Safety
Laboratory Electrical Safety - Tufts Public Safety

PARTIAL DISCHARGE SEMINAR
PARTIAL DISCHARGE SEMINAR

... maintenance of generator windings. Prior to joining Iris in 1996, she worked for the U.S. Army Corps of Engineers for 13 years. While with the Corps she was responsible for the testing and maintenance of hydrogenerator windings, switchgear, transformers, protection and control devices, development o ...
How to use……Bodystat
How to use……Bodystat

Chapter 4_Power Transformer
Chapter 4_Power Transformer

... 2)With the transformer at nominal tap, measure and record the current and voltage at HV side. 3) Calculate the percentage impedance as given below: % Impedance Where Vm = measured voltage Im = measured current Vr = rated voltage Ir = rated current Compare the results with declared value on the namep ...
How to Choose the Best Spark Tester for your Application: AC vs. DC
How to Choose the Best Spark Tester for your Application: AC vs. DC

... Because capacitance is a more a function of the ratio of conductor size to insulation thickness than to overall size, products that produce high capacitance can include cables with large conductors and thin insulation, small wires with very thin dielectric, or multiple conductors going through the s ...
EASTERN ARIZONA COLLEGE AC Electrical Systems
EASTERN ARIZONA COLLEGE AC Electrical Systems

... This course is an introductory course of Alternating Current (AC) theory and systems with a heavy emphasis on industrial application and settings. The course will introduce the student to transformers, electrical measuring test equipment, single and polyphase motors, motor controls, AC generation, a ...
Keysight U1450A/U1460A Series Insulation Resistance Testers
Keysight U1450A/U1460A Series Insulation Resistance Testers

... www.keysight.com/ind/insulationtesters Three-Year Warranty www.keysight.com/find/ ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Ass ...
Maintenance and Testing for the Healthcare Industry — Isolated
Maintenance and Testing for the Healthcare Industry — Isolated

MOTOR TESTING - Haefely Hipotronics
MOTOR TESTING - Haefely Hipotronics

Basic Electrical Engineering Tools And Their Uses
Basic Electrical Engineering Tools And Their Uses

... Electrical engineers are required to work in hazardous environments near energized equipment. There are certain tools they require to carry out their job effectively and safely without causing any harm to themselves and those around them. Here’s a sneak peek into some electrical engineering tools an ...
HVTC Product Information
HVTC Product Information

... increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized ...
The standard for quality with highest voltages. BAUR`s high voltage
The standard for quality with highest voltages. BAUR`s high voltage

1 DIELECTRIC WITHSTAND TESTING OF MODULAR AND
1 DIELECTRIC WITHSTAND TESTING OF MODULAR AND

... During a hipot test, voltage is applied across the insulating material between current carrying conductors and ground. This in fact is very similar to the characteristics of a capacitor, which is simply two conductors separated by an insulating or dielectric material. The circuitry that needs to be ...
AC Voltage (V~) #61-310 Digital Multimeter Instruction Manual
AC Voltage (V~) #61-310 Digital Multimeter Instruction Manual

... meter operation by measuring a known voltage. (2) Apply meter to circuit under test. (3) Return to the known live voltage again to ensure proper operation. • Never ground yourself when taking electrical measurements. • Connect the black common lead to ground before applying the red test lead to volt ...
< 1 ... 162 163 164 165 166 167 168 169 170 >

Portable appliance testing



Portable appliance testing (commonly known as ""PAT"", ""PAT Inspection"" or ""PAT Testing"") is the name of a process in the United Kingdom, the Republic of Ireland, New Zealand and Australia by which electrical appliances are routinely checked for safety. The correct term for the whole process is ""in-service inspection & testing of electrical equipment"".Similar procedures exist in other countries, for example, testing of equipment according to DGUV Vorschrift 3 in Germany.Health and safety regulations require that electrical appliances are safe and maintained to prevent harm to workers. Many equipment manufacturers recommend testing at regular intervals to ensure continual safety; the interval between tests depending on both the type of appliance and the environment in which it is to be used. The European Low Voltage Directive governs the manufacture or importation of electrical appliances. Compliance to this has to be declared and indicated by the display of the CE mark on the product. The responsibility for this lies with the manufacturer or the importer and is policed by Trading Standards.Testing equipment has been specifically developed for PAT inspections, based on the testing equipment used by manufacturers to ensure compliance with the British Standard Code of Practice and European product standards relevant to that type of appliance. This in turn allows testing and the interpretation of results to be de-skilled to a large extent. The inspection of the appliances can largely be carried out in-house in many organisations. This can result in cost savings and more flexibility as to exactly when a PAT is carried out.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report