
Chapter 16 - Wide-Band Oxygen Sensors
... FIGURE 16–23 Typical Ford EDIS 4-cylinder ignition system. The crankshaft sensor, called a variable-reluctance sensor (VRS), sends crankshaft position and speed information to the EDIS module. A modified signal is sent to the computer as a profile ignition pickup (PIP) signal. The PIP is used by th ...
... FIGURE 16–23 Typical Ford EDIS 4-cylinder ignition system. The crankshaft sensor, called a variable-reluctance sensor (VRS), sends crankshaft position and speed information to the EDIS module. A modified signal is sent to the computer as a profile ignition pickup (PIP) signal. The PIP is used by th ...
Ambient RF Energy-Harvesting Technologies for
... (WPT) and harvesting: near-field or far-field system. Nearfield WPT systems utilize electric/magnetic induction or magnetic resonance to transfer power wirelessly and usually have a high transfer efficiency more than 80% within a wavelength from the source [6]–[8], and a relatively longer distance i ...
... (WPT) and harvesting: near-field or far-field system. Nearfield WPT systems utilize electric/magnetic induction or magnetic resonance to transfer power wirelessly and usually have a high transfer efficiency more than 80% within a wavelength from the source [6]–[8], and a relatively longer distance i ...
Concept and importance of Magnetic circuits
... Transformers If the i is decreasing , then the coil on the right side tends to have a current that is opposite to the direction of the increasing current i, this reverses the polarity of the voltage. It can also be noted that , since v= L di/dt , when i is decreasing then v is a negative quanti ...
... Transformers If the i is decreasing , then the coil on the right side tends to have a current that is opposite to the direction of the increasing current i, this reverses the polarity of the voltage. It can also be noted that , since v= L di/dt , when i is decreasing then v is a negative quanti ...
INSTRUCTION MANUALVIBRASWITCH MODEL Euro
... The Vibraswitch, Model EURO 366, is designed to protect rotating, reciprocating, or similar equipment against serious damage from malfunctions that can be detected as an increase in vibration. A reset and holding coil is provided, in the DC/AC voltage as specified so that accidental shutdowns on sta ...
... The Vibraswitch, Model EURO 366, is designed to protect rotating, reciprocating, or similar equipment against serious damage from malfunctions that can be detected as an increase in vibration. A reset and holding coil is provided, in the DC/AC voltage as specified so that accidental shutdowns on sta ...
Basic Electrical Engineering for HVAC Engineers
... Power factor of a circuit is a number that can range from zero to one and it only occurs in an alternating current circuit. Inductance or capacitance in a circuit can cause the voltage sine wave and the current sine wave not to be lined up so they do not reach a peak or zero at exactly the same time ...
... Power factor of a circuit is a number that can range from zero to one and it only occurs in an alternating current circuit. Inductance or capacitance in a circuit can cause the voltage sine wave and the current sine wave not to be lined up so they do not reach a peak or zero at exactly the same time ...
examination branch question bank
... Open Circuit and short circuit tests on a single phase transformer gave the following results. V0=200V, I0=0.7A, WO=20W -------------- test from primary side VS =10V, IS =10A, WS =40W -------------- test from primary side. Determine the efficiency and equivalent circuit referred to primary side? A t ...
... Open Circuit and short circuit tests on a single phase transformer gave the following results. V0=200V, I0=0.7A, WO=20W -------------- test from primary side VS =10V, IS =10A, WS =40W -------------- test from primary side. Determine the efficiency and equivalent circuit referred to primary side? A t ...
FTB 723-1 Equipment Reference Manual P/N
... every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
... every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
Soft Magnetic Materials
... and current transformers, saturable reactors, magnetic amplifiers, inductors, and chokes. These magnetic devices may be required to operate at only 50/60 Hz, or at frequencies down to dc or over 1 MHz. For example, a steel lamination ac mains voltage transformer operates at 50/60 Hz, while its ferri ...
... and current transformers, saturable reactors, magnetic amplifiers, inductors, and chokes. These magnetic devices may be required to operate at only 50/60 Hz, or at frequencies down to dc or over 1 MHz. For example, a steel lamination ac mains voltage transformer operates at 50/60 Hz, while its ferri ...
unit 3 ac machines
... the rotor. As the rotor circuit is closed one so, the current starts flowing in the rotor. This current is called the rotor current. This rotor current produces its own flux called rotor flux. Since this flux is produced due to induction principle so, the motor working on this principle got its name ...
... the rotor. As the rotor circuit is closed one so, the current starts flowing in the rotor. This current is called the rotor current. This rotor current produces its own flux called rotor flux. Since this flux is produced due to induction principle so, the motor working on this principle got its name ...
TEC 88 - Fuji Electric America
... at a special, large factory equipped with state-of-the-art equipment such as dustproof air-conditioning equipment (clean room). Our transformers are backed by continuing research and development in the latest technologies. ...
... at a special, large factory equipped with state-of-the-art equipment such as dustproof air-conditioning equipment (clean room). Our transformers are backed by continuing research and development in the latest technologies. ...
Resonant inductive coupling
Resonant inductive coupling or electrodynamic induction is the near field wireless transmission of electrical energy between two magnetically coupled coils that are part of resonant circuits tuned to resonate at the same frequency. This process occurs in a resonant transformer, an electrical component which consists of two high Q coils wound on the same core with capacitors connected across the windings to make two coupled LC circuits. Resonant transformers are widely used in radio circuits as bandpass filters, and in switching power supplies. Resonant inductive coupling is also being used in wireless power systems. Here the two LC circuits are in different devices; a transmitter coil in one device transmits electric power across an intervening space to a resonant receiver coil in another device. This technology is being developed for powering and charging portable devices such as cellphones and tablet computers at a distance, without being tethered to an outlet.Resonant transfer works by making a coil ring with an oscillating current. This generates an oscillating magnetic field. Because the coil is highly resonant, any energy placed in the coil dies away relatively slowly over very many cycles; but if a second coil is brought near it, the coil can pick up most of the energy before it is lost, even if it is some distance away. The fields used are predominately non-radiative, near fields (sometimes called evanescent waves), as all hardware is kept well within the 1/4 wavelength distance they radiate little energy from the transmitter to infinity.One of the applications of the resonant transformer is for the CCFL inverter. Another application of the resonant transformer is to couple between stages of a superheterodyne receiver, where the selectivity of the receiver is provided by tuned transformers in the intermediate-frequency amplifiers. The Tesla coil is a resonant transformer circuit used to generate very high voltages, and is able to provide much higher current than high voltage electrostatic machines such as the Van de Graaff generator. Resonant energy transfer is the operating principle behind proposed short range (up to 2 metre) wireless electricity systems such as WiTricity or Rezence and systems that have already been deployed, such as Qi power transfer, passive RFID tags and contactless smart cards.