Direct current / alternating current (DC / AC)
... either peak-to-peak or RMS units. It’s your choice, but be sure that you know which you are using. (Reminder: Don’t forget about the “high-Z” setting on the function generator.) Oscilloscope: Again, your choice. It will give values in peak-to-peak or RMS. Make sure that you know what you are reading ...
... either peak-to-peak or RMS units. It’s your choice, but be sure that you know which you are using. (Reminder: Don’t forget about the “high-Z” setting on the function generator.) Oscilloscope: Again, your choice. It will give values in peak-to-peak or RMS. Make sure that you know what you are reading ...
Mechanical Dynamics, the Swing Equation, Units 1.0 Preliminaries
... network and the machine terminals, the less will be the reduction on V, and consequently, the less will be the reduction on Pe (see (10)) and also Te (see (11)). The fault location is something we cannot control of course. But there is another way to prevent reduction in V, ...
... network and the machine terminals, the less will be the reduction on V, and consequently, the less will be the reduction on Pe (see (10)) and also Te (see (11)). The fault location is something we cannot control of course. But there is another way to prevent reduction in V, ...
simulation results - Indico - Variable Energy Cyclotron Centre
... this principle total output voltage (Eq. 1), ripple frequency (Eq. 2) at output stage can be calculated. ...
... this principle total output voltage (Eq. 1), ripple frequency (Eq. 2) at output stage can be calculated. ...
A Tariff for Reactive Power - Department of Electrical Engineering
... supplied by generators and by transmission equipment such as synchronous condensers and static VAR (volt amp reactive) compensators (SVCs) at substations1. SVC and capacitor costs have historically been included in the revenue requirement of the transmission or distribution system operator and recov ...
... supplied by generators and by transmission equipment such as synchronous condensers and static VAR (volt amp reactive) compensators (SVCs) at substations1. SVC and capacitor costs have historically been included in the revenue requirement of the transmission or distribution system operator and recov ...
Effect of Applied Parallel Electric Field on Electroosmotic Flow in
... micro-flow meter in the range of 0.1 to 2 [mm3/sec]. It was shown that there were three different tendencies of the electroosmotic flow rate on the applied electric field. We supposed these differences were derived from the variation of the zeta potential with the electric field: decreasing, increas ...
... micro-flow meter in the range of 0.1 to 2 [mm3/sec]. It was shown that there were three different tendencies of the electroosmotic flow rate on the applied electric field. We supposed these differences were derived from the variation of the zeta potential with the electric field: decreasing, increas ...
experiment - UniMAP Portal
... Figure 3.6 Voltage versus Current Characteristics of a Separately-Excited DC Generator (Fixed Speed) The separately-excited dc generator provides flexible use because its characteristics can be changed by changing the field current. However, a separate dc power source is needed to excite the field e ...
... Figure 3.6 Voltage versus Current Characteristics of a Separately-Excited DC Generator (Fixed Speed) The separately-excited dc generator provides flexible use because its characteristics can be changed by changing the field current. However, a separate dc power source is needed to excite the field e ...
4-20 mA SENSOR / TRANSMITTER MODEL TR
... Carbon Monoxide, Propane and Refrigerant Detector to be free from defects in materials and workmanship under normal use and service for a period of one year. The company’s obligation of this warranty shall be limited to the repair or replacement of any part found to be defective. The company shall n ...
... Carbon Monoxide, Propane and Refrigerant Detector to be free from defects in materials and workmanship under normal use and service for a period of one year. The company’s obligation of this warranty shall be limited to the repair or replacement of any part found to be defective. The company shall n ...
Voltage Stability Analysis of Radial Distribution Networks with
... requires examination of lots of system states and many contingency scenarios. For this reason the approach based on steady state analysis is more feasible, and it can also provide global insight of the voltage reactive power problems [2]. The voltage stability phenomenon has been well recognized in ...
... requires examination of lots of system states and many contingency scenarios. For this reason the approach based on steady state analysis is more feasible, and it can also provide global insight of the voltage reactive power problems [2]. The voltage stability phenomenon has been well recognized in ...
More basic electricity
... Standby Power System: checks the power line and switches to battery power if it detects a problem. The switch takes time (several milliseconds – that’s thousands if not millions of clock cycles) during the switch the computer gets no power. A slight improvement on an SPS is the “Lineinteractive UPS” ...
... Standby Power System: checks the power line and switches to battery power if it detects a problem. The switch takes time (several milliseconds – that’s thousands if not millions of clock cycles) during the switch the computer gets no power. A slight improvement on an SPS is the “Lineinteractive UPS” ...
Paper Title (use style: paper title)
... segments of working hours and other activities. In educational institutions the working hours are again divided into periods. Most of them use alarms to indicate the beginning or the end of a time segment. A person in charge switches or rings the bell. This is a repeating process and may rarely chan ...
... segments of working hours and other activities. In educational institutions the working hours are again divided into periods. Most of them use alarms to indicate the beginning or the end of a time segment. A person in charge switches or rings the bell. This is a repeating process and may rarely chan ...
MAX1472 300MHz-to-450MHz Low-Power, Crystal-Based ASK Transmitter General Description
... In most applications, the MAX1472 PA output has to be impedance matched to a small-loop antenna. The antenna is usually fabricated out of a copper trace on a PC board in a rectangular, circular, or square pattern. The antenna has an impedance that consists of a lossy component and a radiative compon ...
... In most applications, the MAX1472 PA output has to be impedance matched to a small-loop antenna. The antenna is usually fabricated out of a copper trace on a PC board in a rectangular, circular, or square pattern. The antenna has an impedance that consists of a lossy component and a radiative compon ...
Smart grids
... Distributed generation (DG) • Smart grid planning for disaster resiliency must consider disaster impact on lifelines. During disasters special attention should be paid to dissimilar ways in which disasters affect different DG technologies. • Renewable sources do not have lifelines but they are not ...
... Distributed generation (DG) • Smart grid planning for disaster resiliency must consider disaster impact on lifelines. During disasters special attention should be paid to dissimilar ways in which disasters affect different DG technologies. • Renewable sources do not have lifelines but they are not ...
see data sheet for this product
... Congratulations! The product you have selected comes from Hella marine - one of the world's leading manufacturers marine lighting products. Hella marine branded products are covered by a warranty against manufacturing or material defects. (For further details please check the terms of trade with you ...
... Congratulations! The product you have selected comes from Hella marine - one of the world's leading manufacturers marine lighting products. Hella marine branded products are covered by a warranty against manufacturing or material defects. (For further details please check the terms of trade with you ...
B. Tech. (Electrical Engineering)
... & Rectifier type Ammeters & Voltmeters , Electrodynamic Wattmeter, Three Phase Wattmeter, Power in three phase system , errors & remedies in wattmeter and energy meter. ...
... & Rectifier type Ammeters & Voltmeters , Electrodynamic Wattmeter, Three Phase Wattmeter, Power in three phase system , errors & remedies in wattmeter and energy meter. ...
Comparison of Multi-Area Load Frequency Control by PI
... Abstract— In this paper a Fuzzy Logic based load frequency control system (LFC) with Superconductor Magnetic Energy Storage System (SMES) in a multi area electric power system was explained. If a large power imbalance is suddenly happened in a multi area power electric system, generation units and a ...
... Abstract— In this paper a Fuzzy Logic based load frequency control system (LFC) with Superconductor Magnetic Energy Storage System (SMES) in a multi area electric power system was explained. If a large power imbalance is suddenly happened in a multi area power electric system, generation units and a ...
ch27 - AREForum
... assemblies that combine conductor and enclosure are also available. Conductors, copper or aluminum, are sized using the AWG (American Wire Gauge) or kcmil (thousand circular mil) designations. AWG sizes decrease with increasing number; kcmil sizes increase with increasing number. The term “wire” is ...
... assemblies that combine conductor and enclosure are also available. Conductors, copper or aluminum, are sized using the AWG (American Wire Gauge) or kcmil (thousand circular mil) designations. AWG sizes decrease with increasing number; kcmil sizes increase with increasing number. The term “wire” is ...
IECON05_Boost_Integr..
... in a close future, these ballasts will be in the production lines of main national manufacturers. The porpoise of this paper is to report the development of low cost single stage HPF electronic ballast for HPS lamps. The design criteria will be presented in this work for the proposed circuit. There ...
... in a close future, these ballasts will be in the production lines of main national manufacturers. The porpoise of this paper is to report the development of low cost single stage HPF electronic ballast for HPS lamps. The design criteria will be presented in this work for the proposed circuit. There ...
different voltage selection criteria and insulation design of a transmis
... Three main problems associated with EHV, namely radio interference, line insulation and equipment insulation. The various voltages adopted by different countries above 230KV are 275, 287, 345, 380, 400, 500, 735, 1100KV etc. The highest voltage used in India is 400KV. Voltages above 765KV are called ...
... Three main problems associated with EHV, namely radio interference, line insulation and equipment insulation. The various voltages adopted by different countries above 230KV are 275, 287, 345, 380, 400, 500, 735, 1100KV etc. The highest voltage used in India is 400KV. Voltages above 765KV are called ...
2.5.4 Emergency Diesel Generator 1.0 Description
... Each EDG fuel oil storage tank capacity is greater than the volume of fuel oil consumed by the EDG operating at the continuous rating for seven days. ...
... Each EDG fuel oil storage tank capacity is greater than the volume of fuel oil consumed by the EDG operating at the continuous rating for seven days. ...
Electrification
Electrification is the process of powering by electricity and is usually associated with changing over from another power source. The broad meaning of the term, such as in the history of technology and economic history, usually applies to a region or national economy. Broadly speaking, electrification was the build out of the electrical generating and distribution systems which occurred in Britain, the United States, and other countries from the mid-1880s until around 1950 and is in progress in rural areas in some developing countries. This included the change over from line shaft and belt drive using steam engines and water power to electric motors.The electrification of particular sectors of the economy is called by terms such as factory electrification, household electrification, rural electrification or railway electrification. It may also apply to changing industrial processes such as smelting, melting, separating or refining from coal or coke heating or chemical processes to some type of electric process such as electric arc furnace, electric induction or resistance heating or electrolysis or electrolytic separating.Electrification was called ""the greatest engineering achievement of the 20th Century"" by the National Academy of Engineering.