PIC120.241C, PIC120.242C
... voltage range (AC 200-240V) simplifies the circuitry and has significant advantages for reliability, efficiency and cost. The addition of a DC-OK signal makes the unit suitable for many industry applications such as: process, automation and many other critical applications where preventive function ...
... voltage range (AC 200-240V) simplifies the circuitry and has significant advantages for reliability, efficiency and cost. The addition of a DC-OK signal makes the unit suitable for many industry applications such as: process, automation and many other critical applications where preventive function ...
Autonomous Sensor Node Powered by CM
... application is large regarding the wide range of organic substrates that can be used (organic rich sediment, compost, waste water) [1, 2]. It is also noteworthy that they can be deployed in regions where any other energy harvesters would be inappropriate (seafloors, sewage works). Finally, they can ...
... application is large regarding the wide range of organic substrates that can be used (organic rich sediment, compost, waste water) [1, 2]. It is also noteworthy that they can be deployed in regions where any other energy harvesters would be inappropriate (seafloors, sewage works). Finally, they can ...
Energy/Power Breakdown of Pipelined Nanometer
... of total power, and that most of this power is typically dynamic. This can be easily seen in Figure 7, which shows the fraction of total power dissipated by pipeline overhead for all the configurations studied. This is especially noteworthy since we model aggressive clock gating where only latches t ...
... of total power, and that most of this power is typically dynamic. This can be easily seen in Figure 7, which shows the fraction of total power dissipated by pipeline overhead for all the configurations studied. This is especially noteworthy since we model aggressive clock gating where only latches t ...
Measurement & Control for the AC Power Industry
... From a 1, 2 or 3 display meter, 4 channels, total, total 2, peak and valley can be displayed using the UP and DOWN buttons or from a remote switched input. The single phase power input module can be used to measure and display selected combinations of the following: Volts, ...
... From a 1, 2 or 3 display meter, 4 channels, total, total 2, peak and valley can be displayed using the UP and DOWN buttons or from a remote switched input. The single phase power input module can be used to measure and display selected combinations of the following: Volts, ...
数字功率钳表使用说明书
... It meets requirements of safety standards only when the meter is used together with the supplied test probes. In case the test probe is damaged and needs replacement, it is required to replace it with a test probe of the same model and identical electrical specifications. ...
... It meets requirements of safety standards only when the meter is used together with the supplied test probes. In case the test probe is damaged and needs replacement, it is required to replace it with a test probe of the same model and identical electrical specifications. ...
battery charging guide
... outlet for surplus energy (check with your local authorities for Net Metering requirements in your area). Regardless, all battery charging systems must provide protective measures for circumstances of stand alone operation (whether it is a stand alone system or a grid connected system operating as a ...
... outlet for surplus energy (check with your local authorities for Net Metering requirements in your area). Regardless, all battery charging systems must provide protective measures for circumstances of stand alone operation (whether it is a stand alone system or a grid connected system operating as a ...
S. Lim, D.M. Otten and D.J. Perreault, “AC-DC Power Factor Correction Architecture Suitable for High Frequency Operation,” IEEE Transactions on Power Electronics , (to appear).
... ones of the regulating converter outputs and supply a single output. Because the power combining converter operates from a low, narrow-range input voltage, and may not need (in many designs) to provide regulation, it can be designed to be very compact. One possibility in this case is to design it fo ...
... ones of the regulating converter outputs and supply a single output. Because the power combining converter operates from a low, narrow-range input voltage, and may not need (in many designs) to provide regulation, it can be designed to be very compact. One possibility in this case is to design it fo ...
Soft-Switching Full-Bridge PWM DC–DC
... LC filter, and a novel type of secondary snubber. The main part of the converter is a high-frequency full-bridge inverter consisting of four fast IGBTs T1 − T4 and freewheeling diodes D1 − D4 . The high-frequency center-tapped step-down power transformer Tr with very low leakage inductance is used t ...
... LC filter, and a novel type of secondary snubber. The main part of the converter is a high-frequency full-bridge inverter consisting of four fast IGBTs T1 − T4 and freewheeling diodes D1 − D4 . The high-frequency center-tapped step-down power transformer Tr with very low leakage inductance is used t ...
Schneider Electric Altivar ATV18
... (over 3.5 mA). Upstream protection by differential circuit-breaker is not advised as DC elements may be generated by leakage currents from the speed controller. If the installation has several speed controllers on the same supply, connect each speed controller to earth separately. If necessary, prov ...
... (over 3.5 mA). Upstream protection by differential circuit-breaker is not advised as DC elements may be generated by leakage currents from the speed controller. If the installation has several speed controllers on the same supply, connect each speed controller to earth separately. If necessary, prov ...
TB67S269FTG
... The ENABLE pin controls the ON and OFF of the corresponding output stage. This pin serves to select if the motor is stopped in Off (High impedance) mode or activated. Please set the ENABLE pin to ‘L’ during VM power-on and ...
... The ENABLE pin controls the ON and OFF of the corresponding output stage. This pin serves to select if the motor is stopped in Off (High impedance) mode or activated. Please set the ENABLE pin to ‘L’ during VM power-on and ...
Document
... A stand-alone inverter that can inject energy into the grid would be considered a multiple-mode inverter. ...
... A stand-alone inverter that can inject energy into the grid would be considered a multiple-mode inverter. ...
User`s manual ATV18 - Variateur de vitesse
... (over 3.5 mA). Upstream protection by differential circuit-breaker is not advised as DC elements may be generated by leakage currents from the speed controller. If the installation has several speed controllers on the same supply, connect each speed controller to earth separately. If necessary, prov ...
... (over 3.5 mA). Upstream protection by differential circuit-breaker is not advised as DC elements may be generated by leakage currents from the speed controller. If the installation has several speed controllers on the same supply, connect each speed controller to earth separately. If necessary, prov ...
232D Electrical Safety Analyzer
... and the equipment under test. If a hot line to ground fault condition exceeding 10 milliamperes occurs, line voltage is immediately removed from the test receptacle. For conducting more extensive power system tests, both electrical safety analyzers are compatible with the DNI Model 202A Isolated Pow ...
... and the equipment under test. If a hot line to ground fault condition exceeding 10 milliamperes occurs, line voltage is immediately removed from the test receptacle. For conducting more extensive power system tests, both electrical safety analyzers are compatible with the DNI Model 202A Isolated Pow ...
QUICKTRONIC® POWERSENSE® T8 Universal
... For the individual office or conference room, installation can be streamlined by using a 2-wire power line fluorescent dimmer; eliminating the need for additional control wires. For more advanced systems, such as daylight harvesting or building automation applications, standard low voltage devices ...
... For the individual office or conference room, installation can be streamlined by using a 2-wire power line fluorescent dimmer; eliminating the need for additional control wires. For more advanced systems, such as daylight harvesting or building automation applications, standard low voltage devices ...
Motor Single-Phasing Voltage Unbalance
... Allowing a motor to reach and operate at a temperature 10°C above its maximum temperature rating will reduce the motor’s expected life by 50%. Operating at 10°C above this, the motor’s life will be reduced again by 50%. This reduction of the expected life of the motor repeats itself for every 10°C. ...
... Allowing a motor to reach and operate at a temperature 10°C above its maximum temperature rating will reduce the motor’s expected life by 50%. Operating at 10°C above this, the motor’s life will be reduced again by 50%. This reduction of the expected life of the motor repeats itself for every 10°C. ...
Electrification

Electrification is the process of powering by electricity and is usually associated with changing over from another power source. The broad meaning of the term, such as in the history of technology and economic history, usually applies to a region or national economy. Broadly speaking, electrification was the build out of the electrical generating and distribution systems which occurred in Britain, the United States, and other countries from the mid-1880s until around 1950 and is in progress in rural areas in some developing countries. This included the change over from line shaft and belt drive using steam engines and water power to electric motors.The electrification of particular sectors of the economy is called by terms such as factory electrification, household electrification, rural electrification or railway electrification. It may also apply to changing industrial processes such as smelting, melting, separating or refining from coal or coke heating or chemical processes to some type of electric process such as electric arc furnace, electric induction or resistance heating or electrolysis or electrolytic separating.Electrification was called ""the greatest engineering achievement of the 20th Century"" by the National Academy of Engineering.