• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
maxon EC motor EC 32 flat with integrated electronics Document ID: 919778en
maxon EC motor EC 32 flat with integrated electronics Document ID: 919778en

A Wide Temperature Range Pressure Transducer
A Wide Temperature Range Pressure Transducer

... transducer operates over less than half of its full scale and so the actual error will be considerably less than this. With careful calibration the total measurement error can be maintained within +1mmHg (+0.13kPa). Temperature compensation circuits pose additional problems in the calibration proced ...
Brochure
Brochure

... locations, the identification of under-rated equipment in electric power systems and the sizing of various system components. The CYME power engineering software features a comprehensive fault analysis module to assist engineers in the assessment of the effects of short-circuit of varying severity o ...
Transistor - 123SeminarsOnly.com
Transistor - 123SeminarsOnly.com

... a PN diode with the channel which lies between the source and drain. Functionally, this makes the N-channel JFET the solid state equivalent of the vacuum tube triode which, similarly, forms a diode between its grid and cathode. Also, both devices operate in the depletion mode, they both have a high ...
630ES Checkout Routine (PART 2)
630ES Checkout Routine (PART 2)

Document
Document

6100B/6105A Electrical Power Standards Extended Specifications
6100B/6105A Electrical Power Standards Extended Specifications

LTC3566/LTC3566-2 High Effi ciency USB Power Manager Plus 1A Buck-Boost Converter
LTC3566/LTC3566-2 High Effi ciency USB Power Manager Plus 1A Buck-Boost Converter

... Junction temperatures will exceed 125°C when overtemperature protection is active. Continuous operation above the specified maximum operating ...
LOW SKEW 1 TO 4 CLOCK BUFFER ICS553 Description Features
LOW SKEW 1 TO 4 CLOCK BUFFER ICS553 Description Features

... A minimum number of external components are required for proper operation. A decoupling capacitor of 0.01 µF should be connected between VDD on pin 1 and GND on pin 4, as close to the device as possible. A 33 Ω series terminating resistor may be used on each clock output if the trace is longer than ...
4040
4040

... Figure 1: A passive PFC circuit requires only a few components to increase efficiency, but they are large due to operating at the line power frequency. ...
S-57P1 S Series HALL IC
S-57P1 S Series HALL IC

DC MOTOR CONTROLLER USING LINEAR QUADRATIC
DC MOTOR CONTROLLER USING LINEAR QUADRATIC

... Powerful output pin control: Output pins can be driven to high state, using a single instruction. The output pin can drive a load up to 25mA. ...
taylor3
taylor3

... auxiliary unit is not required. The power and torque capability must be such that the rudder can be swung from 35° one side to 35° the other side with the ship at maximum speed, and also the time to swing from 35° one side to 30° the other side must not exceed 28 seconds. The system must be proi-cct ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... required , bridge-type bidirectional converters are become an important [5-7] . A dual full-bridge configuration is usually used for raising the power level and its low side and high side are configured with boost type and buck-type topologies, respectively. Isolation is used for isolating the low v ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... and smaller to increase the density and speed of digital circuits. Reduced power supply voltage is normally not an advantage for analog design and a low supply voltage may require some special circuit techniques. The input-referred latch offset voltage can be reduced by using the pre-amplifier prece ...
Power Electronics - Dr. Imtiaz Hussain
Power Electronics - Dr. Imtiaz Hussain

... the polarity of the main terminals. 2. A triac can be turned on either with a positive or negative voltage at the gate terminal. 3. Like the SCR once the triac is fired into conduction, the gate lose all control. The triac can be turned off by reducing the circuit current to the value of holding cur ...
BM24421426
BM24421426

... in the load parameter surface. Also we can say that it is the upper limit imposed by the system characteristics on the power flowing from generator buses to load buses[6]. In static voltage assessment the transfer limit surface is known as singular surface and is denoted by S having active and react ...
NCP1070, NCP1071, NCP1072, NCP1075, NCP1076, NCP1077 High-Voltage Switcher for
NCP1070, NCP1071, NCP1072, NCP1075, NCP1076, NCP1077 High-Voltage Switcher for

AN3027 Application note How to design a transition-mode PFC pre-regulator
AN3027 Application note How to design a transition-mode PFC pre-regulator

... recommended for higher power levels. To conclude, FF PWM is not the only alternative when CCM operation is desired. FF PWM modulates both switch-on and switch-off times (their sum is constant by definition), and a given converter operates in either CCM or DCM depending on the input voltage and the l ...
Multi-Output Power Supplies with VCOM Amplifier MAX17126/MAX17126A General Description
Multi-Output Power Supplies with VCOM Amplifier MAX17126/MAX17126A General Description

... step-down regulator provides the system with logic supply voltage. Both regulators use fixed-frequency currentmode control architectures, providing fast load-transient response and easy compensation. A current-limit function for internal switches and output-fault shutdown protects the step-up and st ...
Non Sinusoidal Generators
Non Sinusoidal Generators

... By controlling the base current, the collector current can be controlled and thus make the BJT acts like a switch. Ideally, as soon as the base current exceeds the threshold value IB(sat) the BJT should saturate. But, practically it does not happen because of the capacitive effect of transistor The ...
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001

... the grid can cause adverse effects on the operation of Class 1E loads. These degraded voltage conditions will not be detected by the Loss-of-Voltage Relays (LVRs) which are designed to detect loss of power to the bus from the offsite circuit(s). The LVR’s low voltage dropout setting is generally in ...
Switched-mode power supply
Switched-mode power supply

... efficiency is voltage-out/voltage-in since the volt difference is wasted. In contrast, a switched-mode power supply regulates either output voltage or current by switching ideal storage elements, like inductors and capacitors, into and out of different electrical configurations. Ideal switching elem ...
DC Machines - Electrical and Computer Engineering
DC Machines - Electrical and Computer Engineering

... “compensating winding" in series with armature windings so that it’s mmf is proportional to the armature mmf. ...
APPLIED ELECTRONICS Outcome 2
APPLIED ELECTRONICS Outcome 2

< 1 ... 347 348 349 350 351 352 353 354 355 ... 1441 >

Current source



A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report