
Practical Thermocouple Temperature Measurements
... Each SCM5B47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized and converted to a high level analog voltage output (Figure 5). This voltage output is logic-switch controlled, allowing these modules to share a common analog bu ...
... Each SCM5B47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized and converted to a high level analog voltage output (Figure 5). This voltage output is logic-switch controlled, allowing these modules to share a common analog bu ...
The Complete Guide to Electrical Insulation Testing - Techni-Tool
... A further advantage of this double-reading test, as it is sometimes called, is that it gives you a clearer picture, even when a spot reading says the insulation looks fine. For example, let’s say the spot reading on a synchronous motor was 10 megohms. Now, let’s assume that the double-reading check ...
... A further advantage of this double-reading test, as it is sometimes called, is that it gives you a clearer picture, even when a spot reading says the insulation looks fine. For example, let’s say the spot reading on a synchronous motor was 10 megohms. Now, let’s assume that the double-reading check ...
Application Guidelines for Ground Fault Protection
... overcurrent relays that measure the zero-sequence current [7, 15]. Many microprocessor-based relays now offer negative-sequence current elements as a means of detecting ground faults and determining fault direction [4]. Conventional polarization techniques using zero-sequence voltage and current are ...
... overcurrent relays that measure the zero-sequence current [7, 15]. Many microprocessor-based relays now offer negative-sequence current elements as a means of detecting ground faults and determining fault direction [4]. Conventional polarization techniques using zero-sequence voltage and current are ...
Philbrick`s Polyphemus
... flow, pressure, and thermal processes constrained by tanks, pipes, heaters, pumps, and control valves. The analyzer included a three-term controller model with adjustable controller actions (proportional, integral, and derivative-PID), and was furnished with a few bells and whistles for operational ...
... flow, pressure, and thermal processes constrained by tanks, pipes, heaters, pumps, and control valves. The analyzer included a three-term controller model with adjustable controller actions (proportional, integral, and derivative-PID), and was furnished with a few bells and whistles for operational ...
Characterization of atomic layer deposition HfO2, Al2O3
... deposition (LPCVD), plasma-enhanced chemical vapor deposition (PECVD), and atomic layer deposition (ALD).16–24 One of the most common methods to deposit MIM capacitor dielectric in the semiconductor industry is the PECVD method. The films deposited using this method typically result in relatively go ...
... deposition (LPCVD), plasma-enhanced chemical vapor deposition (PECVD), and atomic layer deposition (ALD).16–24 One of the most common methods to deposit MIM capacitor dielectric in the semiconductor industry is the PECVD method. The films deposited using this method typically result in relatively go ...
MAX220–MAX249 +5V-Powered, Multichannel RS-232 Drivers/Receivers General Description
... 20-Pin Wide SO (derate 10 00mW/°C above +70°C).......800mW 24-Pin Wide SO (derate 11.76mW/°C above +70°C).......941mW 28-Pin Wide SO (derate 12.50mW/°C above +70°C) .............1W 44-Pin Plastic FP (derate 11.11mW/°C above +70°C) .....889mW 14-Pin CERDIP (derate 9.09mW/°C above +70°C) ..........727 ...
... 20-Pin Wide SO (derate 10 00mW/°C above +70°C).......800mW 24-Pin Wide SO (derate 11.76mW/°C above +70°C).......941mW 28-Pin Wide SO (derate 12.50mW/°C above +70°C) .............1W 44-Pin Plastic FP (derate 11.11mW/°C above +70°C) .....889mW 14-Pin CERDIP (derate 9.09mW/°C above +70°C) ..........727 ...
Ground Fault Application Guide
... ungrounded or high resistance grounded low voltage systems are sometimes used in certain continuous process applications, and only in applications where there are no line-to-neutral loads involved. If the system is solidly grounded, then ground fault tripping should be applied because high impedance ...
... ungrounded or high resistance grounded low voltage systems are sometimes used in certain continuous process applications, and only in applications where there are no line-to-neutral loads involved. If the system is solidly grounded, then ground fault tripping should be applied because high impedance ...
PTC-NTC for Surface Mounting Application
... circuit idea to connect multiple POSISTORr in series. When One POSISTORr detects overheat at least, a comparator can work by the sharp temperatureresistance characteristic. It easily allows changing a number of POSISTORr or sensing temperature in the same basic circuit design. ...
... circuit idea to connect multiple POSISTORr in series. When One POSISTORr detects overheat at least, a comparator can work by the sharp temperatureresistance characteristic. It easily allows changing a number of POSISTORr or sensing temperature in the same basic circuit design. ...
DC Parameters: Input Offset Voltage (VIO)
... BiFET op amps consist of a JFET input stage and BJTs in the gain and output stages. These devices typically have the highest VIO and temperature drift of the 3 process types. This is attributed to the transconductance of the JFET, which is lower than that of the BJT (see Gray and Meyer [2]). DC prec ...
... BiFET op amps consist of a JFET input stage and BJTs in the gain and output stages. These devices typically have the highest VIO and temperature drift of the 3 process types. This is attributed to the transconductance of the JFET, which is lower than that of the BJT (see Gray and Meyer [2]). DC prec ...
ICL7106/ICL7107 3 ⁄ Digit A/D Converters
... The Maxim ICL7106/ICL7107 are monolithic analog-todigital converters (ADCs). They have very high input impedances and require no external display drive circuitry. On-board active components include polarity and digit drivers, segment decoders, voltage reference and a clock circuit. The ICL7106 will ...
... The Maxim ICL7106/ICL7107 are monolithic analog-todigital converters (ADCs). They have very high input impedances and require no external display drive circuitry. On-board active components include polarity and digit drivers, segment decoders, voltage reference and a clock circuit. The ICL7106 will ...
MAX9789/MAX9790 Windows Vista-Compliant, Stereo Class AB Speaker Amplifiers and DirectDrive Headphone Amplifiers
... Separate speaker and headphone amplifier control inputs provide independent shutdown of the speaker and headphone amplifiers, allowing speaker and headphone amplifiers to be active simultaneously, if required. The industry-leading click-and-pop suppression circuitry reduces audible transients during ...
... Separate speaker and headphone amplifier control inputs provide independent shutdown of the speaker and headphone amplifiers, allowing speaker and headphone amplifiers to be active simultaneously, if required. The industry-leading click-and-pop suppression circuitry reduces audible transients during ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.