• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
How DMMs measure current
How DMMs measure current

Chapter 3 - Three Phase System
Chapter 3 - Three Phase System

... Each transmission line of the 3 wire, three phase system in Figure has an impedance of 15 Ω + j 20 Ω. The system delivers a total power of 160 kW at 12,000 V to a balanced three-phase load with a lagging power factor of 0.86. a. Determine the magnitude of the line voltage EAB of the generator. b. Fi ...
Zetex - AN22 - High frequency DC-DC conversion using high current
Zetex - AN22 - High frequency DC-DC conversion using high current

... of the FMMT718 SuperSOT SOT23 PNP transistor. This circuit, with minimal design optimisation, can produce the efficiency against load current characteristic shown in Figure 10. This chart also shows how the bias conditions for the pass device can be modified to increase the current capability of the ...
AD625 数据手册DataSheet 下载
AD625 数据手册DataSheet 下载

... The diodes to the supplies are only necessary if input voltages outside of the range of the supplies are encountered. In higher gain applications where differential voltages are small, back-toback Zener diodes and smaller resistors, as shown in Figure 26b, provides adequate protection. Figure 26c sh ...
Methods of measuring low, medium and high resistances
Methods of measuring low, medium and high resistances

... Students frequently are confused about when to count a zero as a significant figure. The rule is: If the zero has a non-zero digit anywhere to its left, then the zero is significant, otherwise it is not. For example 5.00 has 3 significant figures; the number 0.0005 has only one significant figure, ...
Siemens Simatic ST70 Control Systems 2011
Siemens Simatic ST70 Control Systems 2011

ASCO Model 430 Guide Specifications (word version)
ASCO Model 430 Guide Specifications (word version)

MAX13481E/MAX13482E/MAX13483E ±15kV ESD-Protected USB Transceivers with External/Internal Pullup Resistors General Description
MAX13481E/MAX13482E/MAX13483E ±15kV ESD-Protected USB Transceivers with External/Internal Pullup Resistors General Description

... The MAX13481E/MAX13482E/MAX13483E ±15kV ESDprotected USB-compliant transceivers convert singleended or differential logic-level signals to USB signals, and USB signals to single-ended or differential logic signals. These devices fully comply to USB 2.0 when operating at full-speed (12Mbps), and oper ...
FSA1208 Low-Power, Eight-Port, High-Speed Isolation Switch FSA1208 — Low-Power, Eight-Port, Features
FSA1208 Low-Power, Eight-Port, High-Speed Isolation Switch FSA1208 — Low-Power, Eight-Port, Features

... IIN=-18mA ...
Electrical Probes
Electrical Probes

... work environment. The Scan-Test™ integrates multiple technologies into one easy to use tool. Scan the wall to find either wood or metal studs for secure installations, while avoiding metal pipes or other metal objects behind the wall. Cuts or nicks in the insulation of wiring can cause long-term pro ...
Development Board EPC9004 Quick Start Guide
Development Board EPC9004 Quick Start Guide

... datasheet available from EPC at www.epc-co.com. The datasheet should be read in conjunction with this quick start guide. ...
A new system of digital circuit blocks for industrial
A new system of digital circuit blocks for industrial

... rule. It is only necessary to know how many NAND This formula gives the relationship between the AND or NOR circuits can be reliably controlled by a preand OR operation and the Negation. It may be seen vious NAND or NOR. There are no other forms of from this that the one operation can always be repl ...
Review_4-5_rd-Reiner - Indico
Review_4-5_rd-Reiner - Indico

...  Voltage “spikes” during 0 V crossing of 600 A power converter (see also talk given by Yves) ...
Application Note AN-47 TOPSwitch-JX Family
Application Note AN-47 TOPSwitch-JX Family

Saturated Load Noise Margin Analysis
Saturated Load Noise Margin Analysis

... With these values we can check our assumption of the operating region of MS: VGS - VTNS = 2.04 - 1 = 1.04 V and VDS = 0.66 V . ...
Advanced Generator Protection and Monitoring Using
Advanced Generator Protection and Monitoring Using

... SSSL and also be inside the UEL. Ideally, the SSSL should sit inside the inner zone. However, because the SSSL location depends on the system strength, this may not be possible. Since the LOF function is constructed from a phase-to-phase or positive-sequence mho element, there is a possibility that ...
SIMATIC S7-200 SMART
SIMATIC S7-200 SMART

... menu design, all menu options can be seen completely. The image of the icon display makes the operation more convenient. By double clicking on the menu, it can be hidden so as to provide more space for a visual programming window. ...
PDF: 2.03MB
PDF: 2.03MB

... P-side: Control circuit Under-Voltage (UV) protection (without fault signal output). N-side: UV and Short-Circuit (SC) protection by means of external shunt resistor (with fault signal output). (4) By virtue of integrating high voltage IC (HVIC) inside, direct coupling to MCU without any opto-couple ...
Scintillation Breakdowns in Tantalum Capacitors
Scintillation Breakdowns in Tantalum Capacitors

2SC0535T Description and Application Manual 2SC0535T
2SC0535T Description and Application Manual 2SC0535T

... and COMx, including that already assembled on the driver. The blocking capacitors must be connected as closely as possible to the driver’s terminal pins with minimum inductance. Ceramic capacitors with a dielectric strength >20V are recommended. If the capacitance C1x (resp. C2x) exceeds 200µF (resp ...
IPS Flyback application note
IPS Flyback application note

... differ by the characteristics of the current sensing references. The IPS20 features a trimmed 50mV reference with a positive temperature coefficient which closely matches that of a PCB copper trace. This copper trace sensing method can be used inexpensively with very low associated power losses. The ...
ZXLD1370
ZXLD1370

... Temperature Adjust input for LED thermal current control. Connect thermistor/resistor network to this pin to reduce output current above a preset temperature ...
Optimization of Electrochemical Wet Etching of Silver STM
Optimization of Electrochemical Wet Etching of Silver STM

... manually in the lab and using automatic commercialized devices. The idea of using silver STM tips is fairly new and the etching process is not as simple as the etching process for tungsten tips. Silver is a relatively soft and significantly malleable metal that bends without much force. These elemen ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676

... The power generation capacity electric boing 787 air bass A380 airplanes is above 1.4 MW and 850KW respectively. In order to reduce the weight of the aircraft electric power should be delivered at a high voltage With low current and low conduction losses this technology leads to simpler Equipment an ...
ADS1209 数据资料 dataSheet 下载
ADS1209 数据资料 dataSheet 下载

... The ADS1209 is a two-channel, high-performance, delta-sigma (ΔΣ) modulator with an 86dB dynamic range, operating from a single +5V supply. The differential inputs are ideal for direct connection to signal sources in an industrial environment. With the appropriate digital filter and modulator rate, t ...
< 1 ... 269 270 271 272 273 274 275 276 277 ... 1441 >

Current source



A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report