
maxon DC motor and maxon EC motor Key
... One can see that at constant applied voltage U and due to the proportionality of torque and current, the efficiency increases with increasing speed (decreasing torque). At low torques, friction losses become increasingly significant and efficiency rapidly approaches zero. Maximum efficiency (line 9 ...
... One can see that at constant applied voltage U and due to the proportionality of torque and current, the efficiency increases with increasing speed (decreasing torque). At low torques, friction losses become increasingly significant and efficiency rapidly approaches zero. Maximum efficiency (line 9 ...
LTC3108 - Ultralow Voltage Step-Up Converter
... voltage is lost. It will be charged up to the maximum VAUX clamp voltage. If not used, this pin should be left open or tied to VAUX. VOUT (Pin 3/Pin 4): Main Output of the Converter. The voltage at this pin is regulated to the voltage selected by VS1 and VS2 (see Table 1). Connect this pin to an ene ...
... voltage is lost. It will be charged up to the maximum VAUX clamp voltage. If not used, this pin should be left open or tied to VAUX. VOUT (Pin 3/Pin 4): Main Output of the Converter. The voltage at this pin is regulated to the voltage selected by VS1 and VS2 (see Table 1). Connect this pin to an ene ...
LTPL-C034UVH430
... The LEDs should be stored at 30°C or less and 85%RH or less. And the LEDs are limited to use within one year, while the LEDs is packed in moisture-proof package with the desiccants inside. The package is opened: The LEDs should be stored at 30°C or less and 60%RH or less. The LEDs are limited to sol ...
... The LEDs should be stored at 30°C or less and 85%RH or less. And the LEDs are limited to use within one year, while the LEDs is packed in moisture-proof package with the desiccants inside. The package is opened: The LEDs should be stored at 30°C or less and 60%RH or less. The LEDs are limited to sol ...
ARC FAULT CIRCUIT INTERRUPTER
... energy is associated with a parallel arcing fault. *Parallel arcing faults result in peak currents above the handle rating of the conventional circuit breaker. This may trip the circuit breaker magnetically, if the impedance of the fault is low and the available fault current is ...
... energy is associated with a parallel arcing fault. *Parallel arcing faults result in peak currents above the handle rating of the conventional circuit breaker. This may trip the circuit breaker magnetically, if the impedance of the fault is low and the available fault current is ...
Control Strategy of Single-Phase Three Level Neutral Point
... Multilevel converters have successfully made their way into the high-power application area and are considered to be a proven technology [1,2]. By increasing the number of modules connected in a series, it is possible to generate more voltage levels to synthesize the input terminal voltage, which ma ...
... Multilevel converters have successfully made their way into the high-power application area and are considered to be a proven technology [1,2]. By increasing the number of modules connected in a series, it is possible to generate more voltage levels to synthesize the input terminal voltage, which ma ...
AAT4650 数据资料DataSheet下载
... Because many AAT4650 applications provide power to external devices, it is designed to protect its host device from malfunctions in those peripherals through slew rate control, current limiting, and thermal limiting. The AAT4650 current limit and thermal limit serve as an immediate and reliable elec ...
... Because many AAT4650 applications provide power to external devices, it is designed to protect its host device from malfunctions in those peripherals through slew rate control, current limiting, and thermal limiting. The AAT4650 current limit and thermal limit serve as an immediate and reliable elec ...
powertronix mizar - O.K.SERVIS PLUS s.r.o.
... Power Supply Systems with forced ventilation cooling.These equipments are characterized by reduced size and high efficiency, thanks to the conversion topology, which doesn’t need transformers between mains, inverter and load. MIZAR UPS belongs to the “double conversion” equipments family, with all a ...
... Power Supply Systems with forced ventilation cooling.These equipments are characterized by reduced size and high efficiency, thanks to the conversion topology, which doesn’t need transformers between mains, inverter and load. MIZAR UPS belongs to the “double conversion” equipments family, with all a ...
Vacuum Gas-FilledRELAys
... applied between external high voltage terminals, or between an open terminal and ground, for up to one minute with no evidence of failure. Peak test voltages must not be exceeded, even for very short pulses. Rated operating voltage (kV Peak) — The voltage that can safely be applied to the relay for ...
... applied between external high voltage terminals, or between an open terminal and ground, for up to one minute with no evidence of failure. Peak test voltages must not be exceeded, even for very short pulses. Rated operating voltage (kV Peak) — The voltage that can safely be applied to the relay for ...
4 Operation
... If nominal system voltage is 12V, make sure battery voltage is higher than 9V before starting the controller. If nominal system voltage is 24V, make sure voltage of battery is no less than 18V; if nominal system voltage is 36V, make sure voltage of battery is no less than 30V; if nominal system volt ...
... If nominal system voltage is 12V, make sure battery voltage is higher than 9V before starting the controller. If nominal system voltage is 24V, make sure voltage of battery is no less than 18V; if nominal system voltage is 36V, make sure voltage of battery is no less than 30V; if nominal system volt ...
Full Experiment: The Ballistic Galvanometer and Damped Oscillations
... The galvanometer with the resistance box P in series with it act as a voltmeter, measuring the voltage drop across the 1Ω resistor, VR. The current that flows through the galvanometer part of the circuit is supplied by this potential difference. VR is made small by dropping the source voltage E (app ...
... The galvanometer with the resistance box P in series with it act as a voltmeter, measuring the voltage drop across the 1Ω resistor, VR. The current that flows through the galvanometer part of the circuit is supplied by this potential difference. VR is made small by dropping the source voltage E (app ...
Reducing EMI in buck converters
... The input supply for the converter is provided by a 3S (~12V) Li-Ion battery, to be independent of other lab equipment. There is an electrolytic capacitor across the battery leads to eliminate resonances due to battery inductance. The converter load is a 1Ω resistor in parallel with a 10µF MLCC capa ...
... The input supply for the converter is provided by a 3S (~12V) Li-Ion battery, to be independent of other lab equipment. There is an electrolytic capacitor across the battery leads to eliminate resonances due to battery inductance. The converter load is a 1Ω resistor in parallel with a 10µF MLCC capa ...
Technical Note - Copley Controls
... implementation of just one phase for simplicity. At each interrupt, the output current is sampled via the A/D converter on board the microcontroller. The algorithm then calculates the difference between the square of the sample and the square of the continuous current limit (determined by H13 and re ...
... implementation of just one phase for simplicity. At each interrupt, the output current is sampled via the A/D converter on board the microcontroller. The algorithm then calculates the difference between the square of the sample and the square of the continuous current limit (determined by H13 and re ...
powertronix mizar
... Power Supply Systems with forced ventilation cooling.These equipments are characterized by reduced size and high efficiency, thanks to the conversion topology, which doesn’t need transformers between mains, inverter and load. MIZAR UPS belongs to the “double conversion” equipments family, with all a ...
... Power Supply Systems with forced ventilation cooling.These equipments are characterized by reduced size and high efficiency, thanks to the conversion topology, which doesn’t need transformers between mains, inverter and load. MIZAR UPS belongs to the “double conversion” equipments family, with all a ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... Yuksel Oguz et al. [27] have presented a design of adaptive neuro-fuzzy inference system (ANFIS) for the turbine speed control for purpose of improving the power quality of the power production system of a split shaft microturbine. To improve the operation performance of the microturbine power gener ...
... Yuksel Oguz et al. [27] have presented a design of adaptive neuro-fuzzy inference system (ANFIS) for the turbine speed control for purpose of improving the power quality of the power production system of a split shaft microturbine. To improve the operation performance of the microturbine power gener ...
Data Sheets
... intended to operate with these low ESR capacitors, they are stable over a wide range of capacitor ESRs. Therefore, they can also work with some higher ESR tantalum or aluminum electrolytic capacitors. However, for best performance, ceramic capacitors are recommended. The value of COUT typically rang ...
... intended to operate with these low ESR capacitors, they are stable over a wide range of capacitor ESRs. Therefore, they can also work with some higher ESR tantalum or aluminum electrolytic capacitors. However, for best performance, ceramic capacitors are recommended. The value of COUT typically rang ...
7 Hints for Precise Current Measurements with the CX3300 Series
... Current sensor (CX1101A, CX1102A, CX1103A) overview As shown at Figure 1, The CX3300 is configured with a dedicated mainframe and three sensors, CX1101A,CX1102A and CX1103A. These sensors are differentiated by bandwidth, current coverage and sensitivity, to satisfy various measurement needs. CX1101A ...
... Current sensor (CX1101A, CX1102A, CX1103A) overview As shown at Figure 1, The CX3300 is configured with a dedicated mainframe and three sensors, CX1101A,CX1102A and CX1103A. These sensors are differentiated by bandwidth, current coverage and sensitivity, to satisfy various measurement needs. CX1101A ...
Aalborg Universitet
... In addition, system dynamic model is particularly essential for state estimation implementation. Small signal model of islanded microgrids is available to represent system dynamic responses under load disturbances [8]. Previous small signal model of a stand-alone microgrid have been established in [ ...
... In addition, system dynamic model is particularly essential for state estimation implementation. Small signal model of islanded microgrids is available to represent system dynamic responses under load disturbances [8]. Previous small signal model of a stand-alone microgrid have been established in [ ...
FJD5553 NPN Silicon Transistor — NPN Silicon T ransistor
... life, and (c) whose failure to perform when properly used in safety or effectiveness. accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. ANTI-COUNTERFEITING POLICY Fairchild Semiconductor Corporation's Anti-Counter ...
... life, and (c) whose failure to perform when properly used in safety or effectiveness. accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. ANTI-COUNTERFEITING POLICY Fairchild Semiconductor Corporation's Anti-Counter ...
MAX8744A/MAX8745A High-Efficiency, Quad-Output, Main Power- Supply Controllers for Notebook Computers General Description
... The MAX8744A/MAX8745A are dual step-down, switchmode, power-supply (SMPS) controllers with synchronous rectification, intended for main 5V/3.3V power generation in battery-powered systems. Fixed-frequency operation with optimal interleaving minimizes input ripple current from the lowest input voltag ...
... The MAX8744A/MAX8745A are dual step-down, switchmode, power-supply (SMPS) controllers with synchronous rectification, intended for main 5V/3.3V power generation in battery-powered systems. Fixed-frequency operation with optimal interleaving minimizes input ripple current from the lowest input voltag ...
Graduate Category: Engineering and Technology Degree Level: Ph.D Abstract ID# 1016
... How does supply noise limit to jitter performance? ...
... How does supply noise limit to jitter performance? ...
SP490E 数据资料DataSheet下载
... SP490ECN-L................................................................................... 0˚C to +70˚C................................................................................ 8-Pin NSOIC SP490ECN-L/TR............................................................................. 0˚C to +70 ...
... SP490ECN-L................................................................................... 0˚C to +70˚C................................................................................ 8-Pin NSOIC SP490ECN-L/TR............................................................................. 0˚C to +70 ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.