dl 2617 six pulse control unit
... •Input summing point for two different reference variables UR and UC and one controlled variable UA. •Signal voltage range: -10 V . . . + 10 V •Continuously adjustable parameters of the two controllers: proportional gain Kp = 0 . . . 1000 integral action time TI = 0.2 ms . . . 20 s •Integral element ...
... •Input summing point for two different reference variables UR and UC and one controlled variable UA. •Signal voltage range: -10 V . . . + 10 V •Continuously adjustable parameters of the two controllers: proportional gain Kp = 0 . . . 1000 integral action time TI = 0.2 ms . . . 20 s •Integral element ...
MT-DB-X3 User Guide November 5, 2014
... The MTDBX3 is a development board for the 64pin Atmel AVR XMEGA A3U, A3BU, C3, and D3 microcontrollers. It can be powered from USB, the PWR IN header, or from a 3V coin cell (CR2032 holder optional). The inputs have PTC resettable fuses (500mA trip) and schottky diodes. Voltage is regulated by t ...
... The MTDBX3 is a development board for the 64pin Atmel AVR XMEGA A3U, A3BU, C3, and D3 microcontrollers. It can be powered from USB, the PWR IN header, or from a 3V coin cell (CR2032 holder optional). The inputs have PTC resettable fuses (500mA trip) and schottky diodes. Voltage is regulated by t ...
$doc.title
... Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous output current, IO ...
... Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous output current, IO ...
CH7022 CH7022 SDTV/EDTV/HDTV Encoder
... for the signals to operate at. The differential p-p input voltage has a min of 175mV, and a max of 1.2V. The differential p-p output voltage has a min of 0.8V, with a max of 1.2V. 2.1.3 Input Clock and Data Timing A data character is transmitted least significant bit first. The beginning of a charac ...
... for the signals to operate at. The differential p-p input voltage has a min of 175mV, and a max of 1.2V. The differential p-p output voltage has a min of 0.8V, with a max of 1.2V. 2.1.3 Input Clock and Data Timing A data character is transmitted least significant bit first. The beginning of a charac ...
MP6507 - Monolithic Power System
... For this control method, the motor current is regulated by an internal constant off-time PWM current control circuit as the following: • Initially, a diagonal pair of MOSFETs turns on so current can flow through the motor winding. • The current increases in the motor winding, which is sensed by an e ...
... For this control method, the motor current is regulated by an internal constant off-time PWM current control circuit as the following: • Initially, a diagonal pair of MOSFETs turns on so current can flow through the motor winding. • The current increases in the motor winding, which is sensed by an e ...
Introduction to HSpice - Universidade Federal de Minas Gerais
... M2 VOUT VIN GND GND nch Wn L M=1 ...
... M2 VOUT VIN GND GND nch Wn L M=1 ...
Ω MAX4721/MAX4722/MAX4723 4.5 Dual SPST Analog Switches in UCSP
... Vapor Phase (60s) .......................................................+215°C ...
... Vapor Phase (60s) .......................................................+215°C ...
SP483E 数据资料DataSheet下载
... EXAR Corporation reserves the right to make changes to any products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no representation that the circuits are free of patent infringement. Charts and schedules contained herein are only for i ...
... EXAR Corporation reserves the right to make changes to any products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no representation that the circuits are free of patent infringement. Charts and schedules contained herein are only for i ...
615-4740 (45-075) Induction Kit
... electro motive force in the other coil will reverse 100 times per second. Because this is so rapid the meter mechanism will not be capable of moving that fast and will appear as a slight vibration and then will appear stationary. At this point, connect an AC voltmeter or better still an oscilloscope ...
... electro motive force in the other coil will reverse 100 times per second. Because this is so rapid the meter mechanism will not be capable of moving that fast and will appear as a slight vibration and then will appear stationary. At this point, connect an AC voltmeter or better still an oscilloscope ...
S270-30-1 (Discontinued)
... detected and interrupted by an upline recloser. As the recloser sequences, the TVS sectionalizer detects loss and restoration of voltage and utilizes time-voltage logic to isolate the section of line impacted by the disturbance. When the TVS sectionalizer is properly installed, and the distribution ...
... detected and interrupted by an upline recloser. As the recloser sequences, the TVS sectionalizer detects loss and restoration of voltage and utilizes time-voltage logic to isolate the section of line impacted by the disturbance. When the TVS sectionalizer is properly installed, and the distribution ...
International Journal of Electrical, Electronics and Computer
... extracted parasitic parameters. The other expressions for the DAC’s INL and DNL errors provided by the model can be used to determine the parasitic values of a real circuit. The rest of this paper is organized as follows. Section 2 analyzes the influence of the DAC on the SAR ADC’s parameters. Secti ...
... extracted parasitic parameters. The other expressions for the DAC’s INL and DNL errors provided by the model can be used to determine the parasitic values of a real circuit. The rest of this paper is organized as follows. Section 2 analyzes the influence of the DAC on the SAR ADC’s parameters. Secti ...
inverter mode operation of the single-phase rectifier
... electrical plane making sure that before this operation was carried out, the reverse connection of the DC motor (it returns to the original connection when the load was operating in quadrant 1) and considering all the restrictions corresponding to the firing angle bringing in the inverter range. Aft ...
... electrical plane making sure that before this operation was carried out, the reverse connection of the DC motor (it returns to the original connection when the load was operating in quadrant 1) and considering all the restrictions corresponding to the firing angle bringing in the inverter range. Aft ...
Y. Huang, S. Wagner, J.C. Sturm, "Nonvolatile Amorphous-Silicon Thin-Film Transistor Structure for Drain-Voltage Independent Saturation Current," IEEE Trans. Elec. Dev. TED-58, pp. 2924-2927 (2011).
... circuitry. If designed to be compatible with the existing TFT fabrication process, they could provide a low-cost and efficient way to integrate memory capabilities into large-area electronics. One potential application is active-matrix organic light emitting diode (OLED) displays, where integrated n ...
... circuitry. If designed to be compatible with the existing TFT fabrication process, they could provide a low-cost and efficient way to integrate memory capabilities into large-area electronics. One potential application is active-matrix organic light emitting diode (OLED) displays, where integrated n ...
ADG417 数据手册DataSheet下载
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to abso ...
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to abso ...
Operation Manual
... NOT short the PV array for regulation, and it is not necessary to derate the controller for short-circuit current (Isc) as is commonly done with shunt controllers. • The rated PV input current and the rated load current can both be exceeded by 25% for up to 5 minutes. This 25% overload will reduce t ...
... NOT short the PV array for regulation, and it is not necessary to derate the controller for short-circuit current (Isc) as is commonly done with shunt controllers. • The rated PV input current and the rated load current can both be exceeded by 25% for up to 5 minutes. This 25% overload will reduce t ...
ZLLS410 Product Summary Features and Benefits
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
LAB 5 Capacitors
... a capacitor is a measure of how much charge can be stored on the capacitor for a given potential difference (voltage). The relation between charge q, voltage V, and capacitance C is given by: q = CV. When two or more capacitors are connected together, they may be replaced by a single capacitor that ...
... a capacitor is a measure of how much charge can be stored on the capacitor for a given potential difference (voltage). The relation between charge q, voltage V, and capacitance C is given by: q = CV. When two or more capacitors are connected together, they may be replaced by a single capacitor that ...
Selling an Idea or a Product
... Capacitance AC Operating Voltage Frequency Operating Temperature Operating Current (Current Limiting Resistor) Physical Size & Mounting Terminal Rating with respect to Ground What Type of MIL-Spec Applies; MIL-PRF-19978, MIL-C-5 or MIL-PRF-39001 ...
... Capacitance AC Operating Voltage Frequency Operating Temperature Operating Current (Current Limiting Resistor) Physical Size & Mounting Terminal Rating with respect to Ground What Type of MIL-Spec Applies; MIL-PRF-19978, MIL-C-5 or MIL-PRF-39001 ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.