
Multifrequency Electronic Ballast For T5 Fluorescent Lamps with
... Fluorescent lamp lifetime is determined by the loss of the electron-emitting coating on the electrodes. Some of the coating is eroded from the electrodes each time the lamp is started, and additional evaporation and erosion also occurs during lamp operation. Electrode temperature directly affects th ...
... Fluorescent lamp lifetime is determined by the loss of the electron-emitting coating on the electrodes. Some of the coating is eroded from the electrodes each time the lamp is started, and additional evaporation and erosion also occurs during lamp operation. Electrode temperature directly affects th ...
Current transformers: how to specify them
... Permanent monitoring of network electrical values by reliable and properly rated current transformers supplying protection relays allows rapid isolation of the faulty area. These relays must ignore transient and normal disturbances but systematically trip when a destructive fault has to be eliminate ...
... Permanent monitoring of network electrical values by reliable and properly rated current transformers supplying protection relays allows rapid isolation of the faulty area. These relays must ignore transient and normal disturbances but systematically trip when a destructive fault has to be eliminate ...
EQW010-040 Series (Eighth-Brick) DC
... * Note: 12.0VO (B) device codes have an adaptable extended Turn-On Delay interval, Tdelay, as specified for B* devices. The extended Tdelay will occur when a 12VO module restarts following either 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout and then back ...
... * Note: 12.0VO (B) device codes have an adaptable extended Turn-On Delay interval, Tdelay, as specified for B* devices. The extended Tdelay will occur when a 12VO module restarts following either 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout and then back ...
harmonic treatment in industrial power systems
... and Q L differ by significant amount. SLX could be defined as “that component of the load apparent voltamperes that Is obtained by the combination of supply voltage harmonics with quadrature Components of corresponding frequency load current harmonics”. ...
... and Q L differ by significant amount. SLX could be defined as “that component of the load apparent voltamperes that Is obtained by the combination of supply voltage harmonics with quadrature Components of corresponding frequency load current harmonics”. ...
TOP242-250 - Power Integrations
... High voltage power MOSFET drain output. The internal start-up bias current is drawn from this pin through a switched high-voltage current source. Internal current limit sense point for drain current. CONTROL (C) Pin: Error amplifier and feedback current input pin for duty cycle control. Internal shun ...
... High voltage power MOSFET drain output. The internal start-up bias current is drawn from this pin through a switched high-voltage current source. Internal current limit sense point for drain current. CONTROL (C) Pin: Error amplifier and feedback current input pin for duty cycle control. Internal shun ...
LTC1799 - 1kHz to 33MHz Resistor Set SOT
... + 20µs. Note the start-up time depends on RSET and it is independent from the setting of the divider pin. For instance with RSET = 50k, the LTC1799 will settle with 1% of its 200kHz final value (N = 10) in approximately 160µs. Figure 6 shows start-up times for various RSET resistors. ...
... + 20µs. Note the start-up time depends on RSET and it is independent from the setting of the divider pin. For instance with RSET = 50k, the LTC1799 will settle with 1% of its 200kHz final value (N = 10) in approximately 160µs. Figure 6 shows start-up times for various RSET resistors. ...
Evaluation Board User Guide UG-199
... for the sole and exclusive purpose referenced above, and agrees not to use the Evaluation Board for any other purpose. Furthermore, the license granted is expressly made subject to the following additional limitations: Customer shall not (i) rent, lease, display, sell, transfer, assign, sublicense, ...
... for the sole and exclusive purpose referenced above, and agrees not to use the Evaluation Board for any other purpose. Furthermore, the license granted is expressly made subject to the following additional limitations: Customer shall not (i) rent, lease, display, sell, transfer, assign, sublicense, ...
Reference Design Report for a 150 W Power Factor Corrected LLC
... Components R34 and C25 provide filtering and bypassing of the +12 V input and the VCC supply for U1. Note: VCC voltage of >15 V may damage U3. Voltage divider resistors R26-29 set the high-voltage turn-on, turn-off, and overvoltage thresholds of U3. The voltage divider values are chosen to set the L ...
... Components R34 and C25 provide filtering and bypassing of the +12 V input and the VCC supply for U1. Note: VCC voltage of >15 V may damage U3. Voltage divider resistors R26-29 set the high-voltage turn-on, turn-off, and overvoltage thresholds of U3. The voltage divider values are chosen to set the L ...
Balboa Video Service Guide
... The Balboa Video Service Guide is the perfect companion to the Balboa Technical Service Manual. You may obtain your copy of the video by contacting Balboa Direct at our toll free number, 1-800-645-3201. The service video and technical service manual are designed to aid you in all your spa repair nee ...
... The Balboa Video Service Guide is the perfect companion to the Balboa Technical Service Manual. You may obtain your copy of the video by contacting Balboa Direct at our toll free number, 1-800-645-3201. The service video and technical service manual are designed to aid you in all your spa repair nee ...
affolder-serialpower
... Serial Power - One cable powers ‘n’ modules each with an equal current. ...
... Serial Power - One cable powers ‘n’ modules each with an equal current. ...
GI750, GI751, GI752, GI754, GI756, GI758 High Current
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
Current transformers: how to specify them
... Permanent monitoring of network electrical values by reliable and properly rated current transformers supplying protection relays allows rapid isolation of the faulty area. These relays must ignore transient and normal disturbances but systematically trip when a destructive fault has to be eliminate ...
... Permanent monitoring of network electrical values by reliable and properly rated current transformers supplying protection relays allows rapid isolation of the faulty area. These relays must ignore transient and normal disturbances but systematically trip when a destructive fault has to be eliminate ...
UNCERTAINTIES IN THE APPLICATION OF ATMOSPHERIC AND
... correction is to be made on withstand test voltage of equipments. This is because in some cases, the relation between the withstand voltage and U50 is not 1.1 times. In some cases the discharge path may not be determined by the voltage level of this test but by other constrains, such as creepage or ...
... correction is to be made on withstand test voltage of equipments. This is because in some cases, the relation between the withstand voltage and U50 is not 1.1 times. In some cases the discharge path may not be determined by the voltage level of this test but by other constrains, such as creepage or ...
Autonomous Sensor Node Powered by CM
... application is large regarding the wide range of organic substrates that can be used (organic rich sediment, compost, waste water) [1, 2]. It is also noteworthy that they can be deployed in regions where any other energy harvesters would be inappropriate (seafloors, sewage works). Finally, they can ...
... application is large regarding the wide range of organic substrates that can be used (organic rich sediment, compost, waste water) [1, 2]. It is also noteworthy that they can be deployed in regions where any other energy harvesters would be inappropriate (seafloors, sewage works). Finally, they can ...
LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset
... Note 2: Short circuits from the output to V+ can cause excessive heating and eventual destruction. When considering short circuits to ground, the maximum output current is approximately 20 mA independent of the magnitude of V+. Note 3: This input current will only exist when the voltage at any of th ...
... Note 2: Short circuits from the output to V+ can cause excessive heating and eventual destruction. When considering short circuits to ground, the maximum output current is approximately 20 mA independent of the magnitude of V+. Note 3: This input current will only exist when the voltage at any of th ...
Evaluation Board User Guide UG-188
... circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. Legal Terms and Conditions By using the evaluation board discussed herein (together with any tools, components documentati ...
... circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. Legal Terms and Conditions By using the evaluation board discussed herein (together with any tools, components documentati ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.