• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
HF Resonators for Damping of VFTs in GIS
HF Resonators for Damping of VFTs in GIS

... possible to compute its resonance frequency f = 1 ( 2π LC ) . However, for the resonator geometry presented in Figure 1 or for any other geometry in general, it is not possible to analytically compute its L and C. A general solution of this problem is the so-called eigenvalue analysis (resonance sea ...
Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... (Note 1) “Renesas Electronics” as used in this document means Renesas Electronics Corporation and also includes its majorityowned subsidiaries. (Note 2) “Renesas Electronics product(s)” means any product developed or manufactured by or for Renesas Electronics. ...
NC7SZU04 TinyLogic UHS Unbuffered Inverter
NC7SZU04 TinyLogic UHS Unbuffered Inverter

... Package drawings are provided as a service to customers considering Fairchild components. Drawings may change in any manner without notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verify or obtain the most recent revision. Package s ...
What Now??? - UCF Physics
What Now??? - UCF Physics

... Consider the circuit in Figure P32.17, taking ε = 6.00 V, L = 8.00 mH, and R = 4.00 Ω. (a) What is the inductive time constant of the circuit? (b) Calculate the current in the circuit 250 μs after the switch is closed. (c) What is the value of the final steady-state current? (d) How long does it tak ...
TDA8932B 1. General description Class-D audio amplifier
TDA8932B 1. General description Class-D audio amplifier

... If the junction temperature of the TDA8932B exceeds the threshold level (Tj > 140 °C) the gain of the amplifier is decreased gradually to a level where the combination of dissipation (P) and the thermal resistance from junction to ambient [Rth(j-a)] results in a junction temperature around the thres ...
74LVT04 3.3V Hex inverter
74LVT04 3.3V Hex inverter

... 3. The input and output negative voltage ratings may be exceeded if the input and output clamp current ratings are observed. ...
PowerLogic Multi-Circuit Meter
PowerLogic Multi-Circuit Meter

VOLTAGE CONTROL IN DISTRIBUTED ELECTRICITY GENERATION BY USING SYNCHRONOUS CONDENSER Mikko Mäkelä
VOLTAGE CONTROL IN DISTRIBUTED ELECTRICITY GENERATION BY USING SYNCHRONOUS CONDENSER Mikko Mäkelä

... allowed to be disconnected from the grid only when the voltage dips are in the area below the limit line. The grid codes also require the system to supply a certain amount of reactive current to support the grid voltage during the fault. It is noted that the limits and ranges for the FRT requirement ...
Licentiate Thesis
Licentiate Thesis

... current is forced to zero. This thesis is based on simulations and experiments to obtain design rules for such a DC-breaker. It has been shows that several aspects needs to be considered. Simulations are performed with several different models to obtain the requirements of each of the components in ...
EE 423 – Power System Analysis 2 Power System Fault Analysis
EE 423 – Power System Analysis 2 Power System Fault Analysis

... The fault analysis of a power system is required in order to provide information for the selection of switchgear, setting of relays and stability of system operation. A power system is not static but changes during operation (switching on or off of generators and transmission lines) and during plann ...
6N135, 6N136 High Speed Optocoupler, 1 MBd
6N135, 6N136 High Speed Optocoupler, 1 MBd

... • High common-mode interference immunity • Bandwidth 2 MHz • Open-collector output ...
ZR285 Description Pin Assignment Typical Application Circuit
ZR285 Description Pin Assignment Typical Application Circuit

... device is available in a small outline surface mount package, ideal for applications where space saving is important. The ZR285 design provides a stable voltage without an external capacitor and is stable with capacitive loads. The ZR285 is recommended for operation between 20μA and 20mA and so is i ...
MAX1606 28V Internal Switch LCD Bias Supply with True Shutdown General Description
MAX1606 28V Internal Switch LCD Bias Supply with True Shutdown General Description

... Inductor Selection Smaller inductance values typically offer smaller physical size for a given series resistance or saturation current. Circuits using larger inductance values may start up at lower input voltages and exhibit less ripple, but also provide reduced output power. This occurs when the in ...
The New PL and New PL-P Series of manual and bus
The New PL and New PL-P Series of manual and bus

... That’s where the V-Span function of the New PL series comes in. It allows the user to redefine the end-stop values of the voltage control to define a specific voltage range. For example: An engineer is working on a circuit that will eventually operate from four NiMh cells. They use V-Span to set a V ...
MAX6922/MAX6932 - Maxim Part Number Search
MAX6922/MAX6932 - Maxim Part Number Search

ADA4940-1/ADA4940-2 (Rev. D)
ADA4940-1/ADA4940-2 (Rev. D)

... The ADA4940-1/ADA4940-2 are low noise, low distortion fully differential amplifiers with very low power consumption. They are an ideal choice for driving low power, high resolution, high performance SAR and Σ-Δ analog-to-digital converters (ADCs) with resolutions up to 16 bits from dc to 1 MHz on on ...
Rockwell Automation Allen-Bradley Specification SMC
Rockwell Automation Allen-Bradley Specification SMC

... to 600 VAC three phase plus 10 percent or minus 15 percent. B. The solid state reduced voltage controller shall have a minimum short circuit current rating of 65 kA when protected with a type CC/J/L fuses (up to 600V). C. Environmental Ratings 1. Storage ambient temperature range: -25 to 75 degrees ...
capacitor switching transient modeling and analysis
capacitor switching transient modeling and analysis

... Figure 4.5: Harmonic Content Present in the Voltage Waveform .................................... 38  Figure 4.6: Transient Response of Phase A ...................................................................... 38  Figure 4.7: Transient Response of Phase A Current Waveform near Load............. ...
PDF: 312KB
PDF: 312KB

... and the gate voltage rises to the “on” level. When the gate voltage is removed, the charges injected into the collector bulk region must be removed before high voltage can be blocked. The IGBT surface emitter pattern is striped geometrically, in contrast to the FET cell-based geometry. The IGBT uses ...
"Is My UPS Distribution System Coordinated?
"Is My UPS Distribution System Coordinated?

... manufacturer should confirm the Alternate Source fault magnitude does not exceed the UPS Alternate Source rating capabilities. 12. When the UPS internal fuses are the single-element currentlimiting type, factory fault testing in combination with upstream and downstream dual-element fuses may be requ ...
T1 Office Repeater Series T1 Office Repeater Series
T1 Office Repeater Series T1 Office Repeater Series

... with the ITT 621170 shelves, while the 1122 offers interchangability with the Lynch 303ST11A Repeater and mounts into the Lynch 302 and 303 series equipment shelves. The 1181 is interchangeable with Rockwell LMS-3192 system components. The repeater derives the required span driving voltage from a 48 ...
Guide to Using the Multimeter
Guide to Using the Multimeter

SN75155 数据资料 dataSheet 下载
SN75155 数据资料 dataSheet 下载

... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
Bates
Bates

IGBT Driver Calculation
IGBT Driver Calculation

... discharging the gate of the IGBT. If the gate peak current is increased, the turn-on and turn-off time will be shorter and the switching losses reduced. This obviously has an impact on other switching parameters such as overvoltage stress, which have to be watched. The gate charge currents can be co ...
< 1 ... 149 150 151 152 153 154 155 156 157 ... 1441 >

Current source



A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report