
Conduction Losses and Common Mode EMI Analysis on
... prototype circuit because it does not require line voltage sensing. It should be noted that switches S1 and S2 in both Dual Boost and Two-circuit-boost PFC are operated simultaneously by the same gate signal from the controller. Although both switches are always gated, only one switch, on which the ...
... prototype circuit because it does not require line voltage sensing. It should be noted that switches S1 and S2 in both Dual Boost and Two-circuit-boost PFC are operated simultaneously by the same gate signal from the controller. Although both switches are always gated, only one switch, on which the ...
Controlling a brush DC motor with an ST6265
... This avoids the use of a speed measurement device and a speed regulation loop. If this voltage measurement / duty adjustment process is carried out often enough, it also results in reducing motor current ripple, and therefore copper and motor iron losses, thus improving motor efficiency. The ripple ...
... This avoids the use of a speed measurement device and a speed regulation loop. If this voltage measurement / duty adjustment process is carried out often enough, it also results in reducing motor current ripple, and therefore copper and motor iron losses, thus improving motor efficiency. The ripple ...
Aalborg Universitet Conditions
... their support and suggestions. I would like to express my gratitude to the honoured preliminary examiners of this doctoral dissertation, Professor Chen Zhe from Aalborg University, Professor Alberto Castellazzi from Nottingham University and Dr. Muhammad Nawaz from ABB, for their time and effort in ...
... their support and suggestions. I would like to express my gratitude to the honoured preliminary examiners of this doctoral dissertation, Professor Chen Zhe from Aalborg University, Professor Alberto Castellazzi from Nottingham University and Dr. Muhammad Nawaz from ABB, for their time and effort in ...
Molded Case Circuit Breakers
... a short circuit occurs, resistance drops to almost zero. Short circuit current can be thousands of times higher than normal operating current. ...
... a short circuit occurs, resistance drops to almost zero. Short circuit current can be thousands of times higher than normal operating current. ...
Conduction Losses and Common Mode EMI Analysis on
... prototype circuit because it does not require line voltage sensing. It should be noted that switches S1 and S2 in both Dual Boost and Two-circuit-boost PFC are operated simultaneously by the same gate signal from the controller. Although both switches are always gated, only one switch, on which the ...
... prototype circuit because it does not require line voltage sensing. It should be noted that switches S1 and S2 in both Dual Boost and Two-circuit-boost PFC are operated simultaneously by the same gate signal from the controller. Although both switches are always gated, only one switch, on which the ...
Chapter 2 - Automation Direct
... The CLICK PLC units make use of data registers to store values and conditions that are used during program execution. This data is stored in the SRAM memory. It is volatile memory, but is backed up by a super capacitor. The super capacitor is a special type of capacitor that is designed to provide p ...
... The CLICK PLC units make use of data registers to store values and conditions that are used during program execution. This data is stored in the SRAM memory. It is volatile memory, but is backed up by a super capacitor. The super capacitor is a special type of capacitor that is designed to provide p ...
Op Amps for Everyone Design Guide (Rev. A)
... chapter can stand alone for the reader with the proper background. Of course, this causes redundancy that some people might find boring, but it’s worth the price to enable the satisfaction of a diversified audience. Start at Chapter 1 if you are a novice, and read through until completion of Chapter ...
... chapter can stand alone for the reader with the proper background. Of course, this causes redundancy that some people might find boring, but it’s worth the price to enable the satisfaction of a diversified audience. Start at Chapter 1 if you are a novice, and read through until completion of Chapter ...
7 Series FPGAs PCB Design Guide (UG483)
... consequential loss or damage (including loss of data, profits, goodwill, or any type of loss or damage suffered as a result of any action brought by a third party) even if such damage or loss was reasonably foreseeable or Xilinx had been advised of the possibility of the same. Xilinx assumes no obli ...
... consequential loss or damage (including loss of data, profits, goodwill, or any type of loss or damage suffered as a result of any action brought by a third party) even if such damage or loss was reasonably foreseeable or Xilinx had been advised of the possibility of the same. Xilinx assumes no obli ...
Earth Faults in Extensive Cable Networks
... At the time of the Gudrun hurricane, the Swedish rural distribution networks were mainly consisting of overhead lines. Network operators became heavily criticised for neglecting continuity of supply and rural consumers. Although an industry-initiated program to increase distribution system reliabili ...
... At the time of the Gudrun hurricane, the Swedish rural distribution networks were mainly consisting of overhead lines. Network operators became heavily criticised for neglecting continuity of supply and rural consumers. Although an industry-initiated program to increase distribution system reliabili ...
QO and QOB - Steven Engineering
... QO-HID and QOB-HID Circuit Breakers QO-HID and QOB-HID circuit breakers are for use in high intensity discharge (HID) lighting systems, such as mercury vapor, metal halide or high-pressure sodium. These circuit breakers are specially designed to handle the high inductive loads, harmonic currents and ...
... QO-HID and QOB-HID Circuit Breakers QO-HID and QOB-HID circuit breakers are for use in high intensity discharge (HID) lighting systems, such as mercury vapor, metal halide or high-pressure sodium. These circuit breakers are specially designed to handle the high inductive loads, harmonic currents and ...
MIXED CIRCUIT AND DEVICE SIMULATION FOR ANALYSIS
... Aon Mujtaba, Zakir Sahul, Xin-Yi Zhang and Edward Chan for the many discussions we had in the lab. Outside the TCAD group, Sunderarajan Sunderesan Mohan, besides being a good friend, provided many interesting discussion on RF circuits. Most importantly, I couldn’t end this section without acknowled ...
... Aon Mujtaba, Zakir Sahul, Xin-Yi Zhang and Edward Chan for the many discussions we had in the lab. Outside the TCAD group, Sunderarajan Sunderesan Mohan, besides being a good friend, provided many interesting discussion on RF circuits. Most importantly, I couldn’t end this section without acknowled ...
Magnecraft™ Power Relays
... 2. Motor horsepower ratings are based on a power factor of 0.4–0.5, and an initial inrush current not exceeding six times the full-load current. 3. All ratings are based on applying the rated nominal power to the relay coil so as to provide a “clean” make and break that does not result in any conta ...
... 2. Motor horsepower ratings are based on a power factor of 0.4–0.5, and an initial inrush current not exceeding six times the full-load current. 3. All ratings are based on applying the rated nominal power to the relay coil so as to provide a “clean” make and break that does not result in any conta ...
High Voltage Power Supplies and X
... With 70 years of high voltage innovation, world-class ISO certified production facilities and global support network, Spellman can meet the needs of discriminating global OEM’s system manufacturers I Compliance and Safety: Safety and Regulatory Agency approvals such as: UL, CSA, and IEC can be provi ...
... With 70 years of high voltage innovation, world-class ISO certified production facilities and global support network, Spellman can meet the needs of discriminating global OEM’s system manufacturers I Compliance and Safety: Safety and Regulatory Agency approvals such as: UL, CSA, and IEC can be provi ...
For instruments with Serial Numbers
... • If this instrument is to be energized via an auto-transformer (for voltage change), make sure the common terminal is connected to the earth terminal of the power source. • Any interruption of the protective (grounding) conductor (inside or outside the instrument), or disconnecting of the protectiv ...
... • If this instrument is to be energized via an auto-transformer (for voltage change), make sure the common terminal is connected to the earth terminal of the power source. • Any interruption of the protective (grounding) conductor (inside or outside the instrument), or disconnecting of the protectiv ...
SERVICE MANUAL GPIB DC Power Supplies Agilent Series 654xA
... • If this instrument is to be energized via an auto-transformer (for voltage change), make sure the common terminal is connected to the earth terminal of the power source. • Any interruption of the protective (grounding) conductor (inside or outside the instrument), or disconnecting of the protectiv ...
... • If this instrument is to be energized via an auto-transformer (for voltage change), make sure the common terminal is connected to the earth terminal of the power source. • Any interruption of the protective (grounding) conductor (inside or outside the instrument), or disconnecting of the protectiv ...
MOTORTRONICS™
... contactors, SCR power modules, instrument transformers and all other medium voltage devices. Adequate room is provided for motor lead connections to be made with minimum conductor bend. A Low Voltage Control Compartment houses the digital microprocessor controller and LCD keypad operator interface, ...
... contactors, SCR power modules, instrument transformers and all other medium voltage devices. Adequate room is provided for motor lead connections to be made with minimum conductor bend. A Low Voltage Control Compartment houses the digital microprocessor controller and LCD keypad operator interface, ...
74HC1G66; 74HCT1G66 1. General description Single-pole single-throw analog switch
... To avoid drawing VCC current out of pin Z, when switch current flows in pin Y, the voltage drop across the bidirectional switch must not exceed 0.4 V. If the switch current flows into pin Z, no VCC current will flow out of terminal Y. In this case there is no limit for the voltage drop across the sw ...
... To avoid drawing VCC current out of pin Z, when switch current flows in pin Y, the voltage drop across the bidirectional switch must not exceed 0.4 V. If the switch current flows into pin Z, no VCC current will flow out of terminal Y. In this case there is no limit for the voltage drop across the sw ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.