• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Compact Adaptive Optics Line Scanning Ophthalmoscope
Compact Adaptive Optics Line Scanning Ophthalmoscope

... study the structural and functional aspects of vision, image elegant and complex retinal circuitry, and the deterioration of such structures and processes during the progression of disease. It has been used in direct measurements of the foveal avascular zone, retinal capillary erythrocyte and leukoc ...
Sign convention
Sign convention

... Light travels left to right Distances to the right are + Heights above the axis are + The radius of a surface is + if its center of curvature is to the right • Focal lengths of converging elements are + • Light traveling in a – direction (after a mirror) uses distances and indices that are negative ...
Stellar Activity with SONG
Stellar Activity with SONG

... gives =6.5 Å or 300km/s  R=10 000 at 6500 Å gives =0.65 Å or 30km/s  R=100 000 at 6500 Å gives =0.065 Å or 3km/s ...
External-cavity diode lasers provide absolute references for WDM
External-cavity diode lasers provide absolute references for WDM

UV Spectroscopy
UV Spectroscopy

MEMS-based handheld confocal microscope for in
MEMS-based handheld confocal microscope for in

Spectroscopy and the Electromagnetic Spectrum
Spectroscopy and the Electromagnetic Spectrum

L2004-01A
L2004-01A

2. Spectral Stray Light
2. Spectral Stray Light

phase retrieval by using transport-of
phase retrieval by using transport-of

Spatial Coherence
Spatial Coherence

Measurement of Surface Quality 1. Lyot Test 2. FECO 3. Nomarski
Measurement of Surface Quality 1. Lyot Test 2. FECO 3. Nomarski

... of the variation of d in that section since there is exact point-to-point correspondence between the selected region and its image on the slit. Small changes in d are determined by measuring small changes in O. There are no ambiguities as to whether a region is a hill or a valley. There are no ambig ...
Determination of Absolute Values of Refractive Index of Liquids
Determination of Absolute Values of Refractive Index of Liquids

... beams the light spots move on the slide mounted mirrors during translation. In case the glass plates used as mirrors do not have high optical surface quality this movement introduces additional displacements δ∆x and δ∆xREF , which are not necessarily equal for the signal and reference beam. We minim ...
Fundamentals of Spectroscopy for Optical Remote Sensing
Fundamentals of Spectroscopy for Optical Remote Sensing

... Spectroscopy is the fundamental for many modern sciences and technologies, and it has found very wide applications. Spectroscopy is a very important approach to study the fundamental matter (fundamental particles, atoms, and molecules, etc.) structures and internal interactions, and to study the dyn ...
Spectroscopy in Organic Chemistry….
Spectroscopy in Organic Chemistry….

Tutorial 4 (PowerPoint)
Tutorial 4 (PowerPoint)

... • The tip and cantilever can bend in two axes to give an idea of the 3D domain structure of a sample • An oscillating voltage is applied to the tip • An oscillating current occurs (due to the capacitance of the tip) which interacts with the B-field of the sample • This creates a measurable force and ...
Lasers and lenses - University of Toronto
Lasers and lenses - University of Toronto

Introduction to super-resolution microscopy
Introduction to super-resolution microscopy

FTIR Spectrometer - Pat Arnott Web Site
FTIR Spectrometer - Pat Arnott Web Site

JBO Letters Towards noncontact skin melanoma selection by
JBO Letters Towards noncontact skin melanoma selection by

Imaging transport:  optical measurements of
Imaging transport: optical measurements of

Noise-related resolution limit of dispersion measurements with white
Noise-related resolution limit of dispersion measurements with white

PART 3_ir spectra_01
PART 3_ir spectra_01

... Are you getting the concept? At what angle would you collect the 1st order diffracted light with l = 500 nm if a broad spectrum beam is incident on a 600 groove/mm grating at qi = 10°? For l = 225 nm? For l = 750 nm? ...
High Throughput Bioanalytical Sample Preparation, Vol 5. Progress in
High Throughput Bioanalytical Sample Preparation, Vol 5. Progress in

Optical Sources and Detectors
Optical Sources and Detectors

< 1 ... 26 27 28 29 30 31 32 33 34 ... 57 >

Chemical imaging

Chemical imaging (as quantitative – chemical mapping) is the analytical capability to create a visual image of components distribution from simultaneous measurement of spectra and spatial, time information.The main idea - for chemical imaging, the analyst may choose to take as many data spectrum measured at a particular chemical component in spatial location at time; this is useful for chemical identification and quantification. Alternatively, selecting an image plane at a particular data spectrum (PCA - multivariable data of wavelength, spatial location at time) can map the spatial distribution of sample components, provided that their spectral signatures are different at the selected data spectrum.Software for chemical imaging is most specific and distinguished from chemical methods such as chemometrics. Hyperspectral imaging is most often applied to either solid or gel samples, and has applications in chemistry, biology, medicine, pharmacy (see also for example: food science, biotechnology, agriculture and industry. NIR, IR and Raman chemical imaging is also referred to as hyperspectral, spectroscopic, spectral or multispectral imaging (also see microspectroscopy). However, other ultra-sensitive and selective imaging techniques are also in use that involve either UV-visible or fluorescence microspectroscopy. Many imaging techniques can be used to analyze samples of all sizes, from the single molecule to the cellular level in biology and medicine, and to images of planetary systems in astronomy, but different instrumentation is employed for making observations on such widely different systems.Imaging instrumentation has three components: a radiation source to illuminate the sample, a spectrally selective element, and usually a detector array (the camera) to collect the images. When many stacked spectral channels (wavelengths) are collected for different locations of the microspectrometer focus on a line or planar array in the focal plane, the data is called hyperspectral; fewer wavelength data sets are called multispectral. The data format is called a hypercube. The data set may be visualized as a data cube, a three-dimensional block of data spanning two spatial dimensions (x and y), with a series of wavelengths (lambda) making up the third (spectral) axis. The hypercube can be visually and mathematically treated as a series of spectrally resolved images (each image plane corresponding to the image at one wavelength) or a series of spatially resolved spectra. Many materials, both manufactured and naturally occurring, derive their functionality from the spatial distribution of sample components. For example, extended release pharmaceutical formulations can be achieved by using a coating that acts as a barrier layer. The release of active ingredient is controlled by the presence of this barrier, and imperfections in the coating, such as discontinuities, may result in altered performance. In the semi-conductor industry, irregularities or contaminants in silicon wafers or printed micro-circuits can lead to failure of these components. The functionality of biological systems is also dependent upon chemical gradients – a single cell, tissue, and even whole organs function because of the very specific arrangement of components. It has been shown that even small changes in chemical composition and distribution may be an early indicator of disease. Any material that depends on chemical gradients for functionality may be amenable to study by an analytical technique that couples spatial and chemical characterization. To efficiently and effectively design and manufacture such materials, the ‘what’ and the ‘where’ must both be measured. The demand for this type of analysis is increasing as manufactured materials become more complex. Chemical imaging techniques is critical to understanding modern manufactured products and in some cases is a non-destructive technique so that samples are preserved for further testing.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report