BD6290EFV : Motor Drivers
... This IC has a built in over current protection circuit as a provision against destruction when the motor outputs are shorted each other or VM-motor output or motor output-GND is shorted. This circuit latches the motor output to OPEN condition when the regulated threshold current flows for 4μs (Typ.) ...
... This IC has a built in over current protection circuit as a provision against destruction when the motor outputs are shorted each other or VM-motor output or motor output-GND is shorted. This circuit latches the motor output to OPEN condition when the regulated threshold current flows for 4μs (Typ.) ...
- I vb5q6
... A pulley system has three pulleys. A load of I20N is overcome by applying an effort of 50N. Calculate the Mechanical Advantage and Efficiency of this sYstem. ...
... A pulley system has three pulleys. A load of I20N is overcome by applying an effort of 50N. Calculate the Mechanical Advantage and Efficiency of this sYstem. ...
MAX5069 High-Frequency, Current-Mode PWM Controller with Accurate Oscillator and Dual FET Drivers
... with Accurate Oscillator and Dual FET Drivers The MAX5069 is a high-frequency, current-mode, pulse-width modulation (PWM) controller (with dual MOSFET drivers) that integrates all the building blocks necessary for implementing AC-DC or DC-DC fixed-frequency power supplies. Isolated or nonisolated pu ...
... with Accurate Oscillator and Dual FET Drivers The MAX5069 is a high-frequency, current-mode, pulse-width modulation (PWM) controller (with dual MOSFET drivers) that integrates all the building blocks necessary for implementing AC-DC or DC-DC fixed-frequency power supplies. Isolated or nonisolated pu ...
Engineering Standards for Power Design Specifications
... “normal and spare”, “2 of 3 normally running”, or equivalent, or if 2 or more motors in the same service can operate independently for partial service (as in air-cooled heat exchanger fans and paralleled cooling water circulation pumps), the following shall govern: a. If such motors are fed directly ...
... “normal and spare”, “2 of 3 normally running”, or equivalent, or if 2 or more motors in the same service can operate independently for partial service (as in air-cooled heat exchanger fans and paralleled cooling water circulation pumps), the following shall govern: a. If such motors are fed directly ...
Heathkit of the Month: by Bob Eckweiler, AF6C Heath DX
... transmitters were built for the war effort. They flew in Navy and Army fighters and bombers. The HF transmitters use a pair of 1625 tubes in the final RF amplifier. After the war these tubes were plentiful and very inexpensive. They are identical to the 807 except that they have a 12volt filament an ...
... transmitters were built for the war effort. They flew in Navy and Army fighters and bombers. The HF transmitters use a pair of 1625 tubes in the final RF amplifier. After the war these tubes were plentiful and very inexpensive. They are identical to the 807 except that they have a 12volt filament an ...
Lab 7 - Ohm`s Law and Resistors in Series and Parallel
... 6. Adjust the CURRENT control knob so that the ammeter reads 0.5 A. Record the current and voltage in a table which leaves room for three more sets of readings. Record the current and voltage to the correct number of significant figures, recalling that the least significant figure is an estimate and ...
... 6. Adjust the CURRENT control knob so that the ammeter reads 0.5 A. Record the current and voltage in a table which leaves room for three more sets of readings. Record the current and voltage to the correct number of significant figures, recalling that the least significant figure is an estimate and ...
How to select the Triac, ACS, or ACST that fits your application
... Motor control applications A BEMF can be applied by a motor when the series AC switch is OFF. A motor can still be running due to inertia or if a mechanical torque is applied. A BEMF will occur across a motor if it is turning and if an inductive field is applied. This is the reason why, such a BEMF ...
... Motor control applications A BEMF can be applied by a motor when the series AC switch is OFF. A motor can still be running due to inertia or if a mechanical torque is applied. A BEMF will occur across a motor if it is turning and if an inductive field is applied. This is the reason why, such a BEMF ...
ECE1250F14_Lab7_LevelShift
... Build several level-shifter circuits that shift voltages coming out of a comparator to voltages appropriate for the inputs of logic gates. Calculate the output voltages of various level-shifter circuits. Measure the output voltages of various level-shifter circuits. Design a level shifter ci ...
... Build several level-shifter circuits that shift voltages coming out of a comparator to voltages appropriate for the inputs of logic gates. Calculate the output voltages of various level-shifter circuits. Measure the output voltages of various level-shifter circuits. Design a level shifter ci ...
Direct current voltage increment due to ac coupling in a high Tc
... silver-sheathed Bi2Sr2Ca2Cu3O101d superconducting tapes has resulted in relatively long wires with improved electrical and mechanical characteristics.1,2 This progress has enabled the fabrication of high-temperature superconducting ~HTS! coils for the construction of power devices such as magnets, t ...
... silver-sheathed Bi2Sr2Ca2Cu3O101d superconducting tapes has resulted in relatively long wires with improved electrical and mechanical characteristics.1,2 This progress has enabled the fabrication of high-temperature superconducting ~HTS! coils for the construction of power devices such as magnets, t ...
Click here to view/download the Digital I/O Output tutorial
... The external load, such as a 12 VDC piezo buzzer, is connected to the + VDC of the external power supply. The switched side of the load is connected to output 0, on pin 2 (OUT0) of the 9 pin Digital I/O connector. 0 volts of the power supply is connected to pin 1 (GND) of 9 pin Digital I/O connector ...
... The external load, such as a 12 VDC piezo buzzer, is connected to the + VDC of the external power supply. The switched side of the load is connected to output 0, on pin 2 (OUT0) of the 9 pin Digital I/O connector. 0 volts of the power supply is connected to pin 1 (GND) of 9 pin Digital I/O connector ...
Simulation and Measurement of an On-Die Power
... switch gate is introduced to the SOC to reduce the leakage current from the un-used IP block during power-saving mode. However, the resistive path between the drain and source of the power switch gate itself can introduce additional IR loss and reduce the DC voltage margin. The complexity adds on as ...
... switch gate is introduced to the SOC to reduce the leakage current from the un-used IP block during power-saving mode. However, the resistive path between the drain and source of the power switch gate itself can introduce additional IR loss and reduce the DC voltage margin. The complexity adds on as ...
Model UP150 Program Temperature Controller
... Normal mode noise: Min. 40dB Common mode noise: Min. 120dB (Min. 90dB for DC V input) Error of reference junction compensation: ±1.5°C (at 15-35°C) ±2.0°C (at 0-50°C) The reference junction compensation cannot be switched off. Applicable standards: Thermocouple and resistance temperature detector(RT ...
... Normal mode noise: Min. 40dB Common mode noise: Min. 120dB (Min. 90dB for DC V input) Error of reference junction compensation: ±1.5°C (at 15-35°C) ±2.0°C (at 0-50°C) The reference junction compensation cannot be switched off. Applicable standards: Thermocouple and resistance temperature detector(RT ...
Serial Single
... Dymec models 5843 and 5844 are hardened fiber optic Link/Repeaters that convert RS232 or TTL level copper to amplitude based fiber output. Supports data rates from dc to 250k bps, DCE or DTE port configuration and a diagnostic/test mode that allows testing of the copper and fiber connections before ...
... Dymec models 5843 and 5844 are hardened fiber optic Link/Repeaters that convert RS232 or TTL level copper to amplitude based fiber output. Supports data rates from dc to 250k bps, DCE or DTE port configuration and a diagnostic/test mode that allows testing of the copper and fiber connections before ...
OCXO Layout Guidelines - Connor
... an external source and steps it down to a suitable voltage level that can power components on the circuit board. Two common types of voltage regulators are dc-dc converters and low-dropout regulators (LDO). When deciding on a voltage regulator, always review the regulator data sheets to match compon ...
... an external source and steps it down to a suitable voltage level that can power components on the circuit board. Two common types of voltage regulators are dc-dc converters and low-dropout regulators (LDO). When deciding on a voltage regulator, always review the regulator data sheets to match compon ...
6-W, 3.3-V/5-V INPUT, WIDE ADJUST OUTPUT, POSITIVE-TO-NEGATIVE CONVERTER PTN04050A FEATURES APPLICATIONS
... ripple) is standard practice to ensure reliability. Polymer-tantalum capacitors are more reliable and are available with a maximum rating of typically 20 V. Output Capacitor The minimum capacitance required to ensure stability is a 100 µF. Either ceramic or electrolytic-type capacitors can be used. ...
... ripple) is standard practice to ensure reliability. Polymer-tantalum capacitors are more reliable and are available with a maximum rating of typically 20 V. Output Capacitor The minimum capacitance required to ensure stability is a 100 µF. Either ceramic or electrolytic-type capacitors can be used. ...
Aalborg Universitet
... therefore the SOC of the three modules with higher value are maintained almost equal. It can be noticed that after one hour the SOC difference is 9% approximately and after one and a half hours the SOC difference has been reduced to around 3%. Fig. 8. Simulation model for balancing algorithm testing ...
... therefore the SOC of the three modules with higher value are maintained almost equal. It can be noticed that after one hour the SOC difference is 9% approximately and after one and a half hours the SOC difference has been reduced to around 3%. Fig. 8. Simulation model for balancing algorithm testing ...
Chapter 14
... The categorization of CROs is done on the basis of whether they are digital or analog. Digital CROs can be further classified as storage oscilloscopes. 1. Analog CRO: In an analog CRO, the amplitude, phase and frequency are measured from the displayed waveform, through direct manual reading. 2. Digi ...
... The categorization of CROs is done on the basis of whether they are digital or analog. Digital CROs can be further classified as storage oscilloscopes. 1. Analog CRO: In an analog CRO, the amplitude, phase and frequency are measured from the displayed waveform, through direct manual reading. 2. Digi ...
Parallel Circuits
... • each electron has the same amount of energy, and electrons must lose all their energy on the path they are on. • this is why the potential difference across parallel resistors will always be the same, even though the resistors themselves are different ...
... • each electron has the same amount of energy, and electrons must lose all their energy on the path they are on. • this is why the potential difference across parallel resistors will always be the same, even though the resistors themselves are different ...
Power electronics
Power electronics is the application of solid-state electronics to the control and conversion of electric power. It also refers to a subject of research in electronic and electrical engineering which deals with the design, control, computation and integration of nonlinear, time-varying energy-processing electronic systems with fast dynamics.The first high power electronic devices were mercury-arc valves. In modern systems the conversion is performed with semiconductor switching devices such as diodes, thyristors and transistors, pioneered by R. D. Middlebrook and others beginning in the 1950s. In contrast to electronic systems concerned with transmission and processing of signals and data, in power electronics substantial amounts of electrical energy are processed. An AC/DC converter (rectifier) is the most typical power electronics device found in many consumer electronic devices, e.g. television sets, personal computers, battery chargers, etc. The power range is typically from tens of watts to several hundred watts. In industry a common application is the variable speed drive (VSD) that is used to control an induction motor. The power range of VSDs start from a few hundred watts and end at tens of megawatts.The power conversion systems can be classified according to the type of the input and output power AC to DC (rectifier) DC to AC (inverter) DC to DC (DC-to-DC converter) AC to AC (AC-to-AC converter)