Full Feaured N+1 and ORing Power Rail Controller (Rev. C)
... exceeds 10 mV. Both devices provide a strong GATE pull-down when V(AC) is less than the programmable fast turn-off threshold. The TPS2410 has a soft pull-down when V(AC) is less than 10 mV but above the fast turn-off threshold. Several internal comparator and amplifier circuits monitor these two pin ...
... exceeds 10 mV. Both devices provide a strong GATE pull-down when V(AC) is less than the programmable fast turn-off threshold. The TPS2410 has a soft pull-down when V(AC) is less than 10 mV but above the fast turn-off threshold. Several internal comparator and amplifier circuits monitor these two pin ...
Interfacing LVPECL 3.3V Drivers with Xilinx 2.5V Differential Receivers Summary
... Inserting a series capacitor and biasing network into each leg of the differential receiver allows a reduction of the common mode voltage. This technique can provide protection against extreme DC voltages and can be useful for board-to-board or system-to-system interfaces. An example of such an inte ...
... Inserting a series capacitor and biasing network into each leg of the differential receiver allows a reduction of the common mode voltage. This technique can provide protection against extreme DC voltages and can be useful for board-to-board or system-to-system interfaces. An example of such an inte ...
DAC2904 数据资料 dataSheet 下载
... The data input ports of the DAC2904 accept a standard positive coding with data bit D13 being the most significant bit (MSB). The converter outputs support a clock rate of up to 125MSPS. The best performance will typically be achieved with a symmetric duty cycle for write and clock; however, the dut ...
... The data input ports of the DAC2904 accept a standard positive coding with data bit D13 being the most significant bit (MSB). The converter outputs support a clock rate of up to 125MSPS. The best performance will typically be achieved with a symmetric duty cycle for write and clock; however, the dut ...
AAT4684 数据资料DataSheet下载
... family. It is a P-channel MOSFET power switch with precise over-voltage protection control, designed to protect low-voltage systems against high-voltage faults up to +28V. If the input voltage exceeds the programmed over-voltage threshold, the P-channel MOSFET switch will be turned off to prevent da ...
... family. It is a P-channel MOSFET power switch with precise over-voltage protection control, designed to protect low-voltage systems against high-voltage faults up to +28V. If the input voltage exceeds the programmed over-voltage threshold, the P-channel MOSFET switch will be turned off to prevent da ...
TTL - UStudy.in
... As such all the families of TTL have three configuration for outputs. Totem - Pole output. ...
... As such all the families of TTL have three configuration for outputs. Totem - Pole output. ...
LT6105 Precision, Extended Input Range Current Sense Amplifi er FEATURES
... amplifier with a very wide input common mode range. The LT6105 monitors unidirectional current via the voltage across an external sense resistor. The input common mode range extends from –0.3V to 44V, with respect to the negative supply voltage (V –). This allows the LT6105 to operate as a high side ...
... amplifier with a very wide input common mode range. The LT6105 monitors unidirectional current via the voltage across an external sense resistor. The input common mode range extends from –0.3V to 44V, with respect to the negative supply voltage (V –). This allows the LT6105 to operate as a high side ...
ATMOSPHERIC DISCHARGE EFFECT ON POWER NETWORKS
... Abstract: The main effect of lightning is the induction of the surge voltage within power networks. The paper deals with the description and analysis of the atmospheric discharges and lightning models which affect the AC medium voltage overhead power lines. The surge voltage waveforms for different ...
... Abstract: The main effect of lightning is the induction of the surge voltage within power networks. The paper deals with the description and analysis of the atmospheric discharges and lightning models which affect the AC medium voltage overhead power lines. The surge voltage waveforms for different ...
Diode Clippers
... • Series Diode Clipper When diode is “OFF”, there should be no transmission of input signal to output. But in case of high frequency, signal transmission occurs through diode capacitance which is undesirable. ...
... • Series Diode Clipper When diode is “OFF”, there should be no transmission of input signal to output. But in case of high frequency, signal transmission occurs through diode capacitance which is undesirable. ...
xpsmf3502 - Schneider Electric
... Closed circuit scanning of input channels for analogue input circuit Measuring 0 to 20 mA currents using shunt for analogue input circuit Monitoring safety actuators for discrete output Monitoring safety detection for discrete input Monitoring safety dialogue for discrete input Monitoring safety dia ...
... Closed circuit scanning of input channels for analogue input circuit Measuring 0 to 20 mA currents using shunt for analogue input circuit Monitoring safety actuators for discrete output Monitoring safety detection for discrete input Monitoring safety dialogue for discrete input Monitoring safety dia ...
semiconductor circuit templates
... regulated output voltage value if the unregulated input supply voltage is the same for both. ...
... regulated output voltage value if the unregulated input supply voltage is the same for both. ...
Cooper_Silicon_Mechanics_110508
... • Others are far more knowledgeable about TPC cooling requirements. Accordingly, I’ll restrict my comments to silicon portions of the tracker and to the vertex detector. • Early evaluations for the SiD outer silicon tracker for the ILC assumed a power dissipation of 17.4 μW per channel averaged over ...
... • Others are far more knowledgeable about TPC cooling requirements. Accordingly, I’ll restrict my comments to silicon portions of the tracker and to the vertex detector. • Early evaluations for the SiD outer silicon tracker for the ILC assumed a power dissipation of 17.4 μW per channel averaged over ...
Word - ITU
... Definition: Expression in logarithmic form, usually in decibels, of the ratio between the power density at a given point and a reference power density. NOTE 1 – For example, if one watt per square metre is chosen as the reference power flux-density, the absolute power flux-density levels are express ...
... Definition: Expression in logarithmic form, usually in decibels, of the ratio between the power density at a given point and a reference power density. NOTE 1 – For example, if one watt per square metre is chosen as the reference power flux-density, the absolute power flux-density levels are express ...
Latest Placement Papers for your Dream Concern Eye shot of ABB
... TECHNICAL PAPER-40 QUESTION, 45- MINUTES (1)in a ckt. We r giving voltage of 50 Hz as well as 60. then what will be the resultant frequency. (a)less than 50 (b)more than 60(c)in between 50 & 60 (d)none..........according to our conclusion answer will be none because if we apply two frequency compone ...
... TECHNICAL PAPER-40 QUESTION, 45- MINUTES (1)in a ckt. We r giving voltage of 50 Hz as well as 60. then what will be the resultant frequency. (a)less than 50 (b)more than 60(c)in between 50 & 60 (d)none..........according to our conclusion answer will be none because if we apply two frequency compone ...
Electric Currents
... A common mistake is to think the current gets used up in passing through the resistances in a series circuit. The same current must pass through each component much like the continuous flow of water in a pipe. ...
... A common mistake is to think the current gets used up in passing through the resistances in a series circuit. The same current must pass through each component much like the continuous flow of water in a pipe. ...
V - C Finn
... There are two main reasons why parallel circuits are used more commonly than series circuits: 1) Extra appliances (like bulbs) can be added without affecting the output of the others ...
... There are two main reasons why parallel circuits are used more commonly than series circuits: 1) Extra appliances (like bulbs) can be added without affecting the output of the others ...
S4100
... Architects and Engineers Specifications When notification appliances are required for applications with more than one function, an appliance with multiple inputs and capable of being programmed shall be used. The notification appliance shall be capable of accepting three (3) individual DC signals a ...
... Architects and Engineers Specifications When notification appliances are required for applications with more than one function, an appliance with multiple inputs and capable of being programmed shall be used. The notification appliance shall be capable of accepting three (3) individual DC signals a ...
Chapter 13 Electric Circuits
... A common mistake is to think the current gets used up in passing through the resistances in a series circuit. The same current must pass through each component much like the ! continuous flow of water in a pipe. ...
... A common mistake is to think the current gets used up in passing through the resistances in a series circuit. The same current must pass through each component much like the ! continuous flow of water in a pipe. ...
PNIMNiPE_nr63
... parameters (low values of temperature and VCR), were hard to reach and very expensive. However in the last few years the situation considerably improved because there is in sale a new generation of high-ohmic resistors, so called metal-oxide - MOX. In metal-oxide resistors the resistive path is made ...
... parameters (low values of temperature and VCR), were hard to reach and very expensive. However in the last few years the situation considerably improved because there is in sale a new generation of high-ohmic resistors, so called metal-oxide - MOX. In metal-oxide resistors the resistive path is made ...
13-14 thru 13-26
... generator rotor is in the 345° position, the field axis is 15° clockwise from the axis of the S2 secondary coil, the voltage induced in it equals 52 cos (-15°). Likewise the voltages induced in Sl and S3 equal 52 cos (-255°) and 52 cos ( -135°). These voltages set up a field in the motor which equal ...
... generator rotor is in the 345° position, the field axis is 15° clockwise from the axis of the S2 secondary coil, the voltage induced in it equals 52 cos (-15°). Likewise the voltages induced in Sl and S3 equal 52 cos (-255°) and 52 cos ( -135°). These voltages set up a field in the motor which equal ...
Power electronics
Power electronics is the application of solid-state electronics to the control and conversion of electric power. It also refers to a subject of research in electronic and electrical engineering which deals with the design, control, computation and integration of nonlinear, time-varying energy-processing electronic systems with fast dynamics.The first high power electronic devices were mercury-arc valves. In modern systems the conversion is performed with semiconductor switching devices such as diodes, thyristors and transistors, pioneered by R. D. Middlebrook and others beginning in the 1950s. In contrast to electronic systems concerned with transmission and processing of signals and data, in power electronics substantial amounts of electrical energy are processed. An AC/DC converter (rectifier) is the most typical power electronics device found in many consumer electronic devices, e.g. television sets, personal computers, battery chargers, etc. The power range is typically from tens of watts to several hundred watts. In industry a common application is the variable speed drive (VSD) that is used to control an induction motor. The power range of VSDs start from a few hundred watts and end at tens of megawatts.The power conversion systems can be classified according to the type of the input and output power AC to DC (rectifier) DC to AC (inverter) DC to DC (DC-to-DC converter) AC to AC (AC-to-AC converter)