• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Working with Stepper Motors
Working with Stepper Motors

... 6-, and 12-volt operation are not uncommon. But unlike DC motors, if you use a higher voltage than specified for a stepper motor you don’t gain faster operation, but more running ...
Specification Number: 16440-1
Specification Number: 16440-1

... E. The complete assembly shall be constructed in accordance with applicable provisions of ANSI / IEEE C37.20.3-1987 and the minimum construction standards of the manufacturers of the major components such as power fuses or potential transformers. Provide adequate space for fuse handling when applica ...
grid code requirements for wind turbines turbines connected
grid code requirements for wind turbines turbines connected

TS3L501E 数据资料 dataSheet 下载
TS3L501E 数据资料 dataSheet 下载

Functional description short white paper ASDS for Main
Functional description short white paper ASDS for Main

... connect the inverter module. The mechanical breaker only makes it possible for the inverter to be connected to the DC-link. The mechanical breaker also makes it possible to isolate the transistor module completely from the DC-bus. It is the associated VSD local control panel or remote operation whic ...
Data Assessment for Electrical Surge Protection Devices
Data Assessment for Electrical Surge Protection Devices

... Residential surge protection has long been viewed as an important safety consideration and guidance has been issued by IEEE and NIST to help homeowners protect their house and its contents. This protection has often been described as being similar to an insurance policy, partly because there is not ...
NTS0102 1. General description Dual supply translating transceiver; open drain; auto
NTS0102 1. General description Dual supply translating transceiver; open drain; auto

... any of the voltage nodes (1.8 V, 2.5 V, 3.3 V and 5.0 V). Pins An and OE are referenced to VCC(A) and pins Bn are referenced to VCC(B). A LOW level at pin OE causes the outputs to assume a high-impedance OFF-state. This device is fully specified for partial power-down applications using IOFF. The IO ...
Ferroelectric Characterization Tutorial
Ferroelectric Characterization Tutorial

vacon 10 complete user manual ac drives
vacon 10 complete user manual ac drives

... Category C1: Frequency converters of this class comply with the requirements of category C1 of the product standard EN 61800-3 (2004). Category C1 ensures the best EMC characteristics and it includes converters the rated voltage of which is less than 1000 V and which are intended for use in the 1st ...
MAX220–MAX249 +5V-Powered, Multichannel RS
MAX220–MAX249 +5V-Powered, Multichannel RS

... Available in quad flatpack package ...
EASA-Shaft-Bearing
EASA-Shaft-Bearing

... distortion. The finished core thus amplifies the minute distortions since they effectively add up as they distort the magnetic circuit. Smaller cores that use single piece laminations are much less likely to cause magnetic distortion, but it is still possible. A potential reason is that one of the m ...
FRENIC-EcoPAK NonBypass EngSpec_FECA-TE-103E
FRENIC-EcoPAK NonBypass EngSpec_FECA-TE-103E

... the reverse direction. U. The drive shall have the ability to start into a rotating motor, at any speed and direction, then accelerate or decelerate the motor to the speed reference set-point without stopping the motor, tripping the drive, or component failure under normal operating conditions. V. A ...
Thevenin & Norton Equivalent
Thevenin & Norton Equivalent

Electronics Computer Club “the geek club”
Electronics Computer Club “the geek club”

Contract Specific Requirements
Contract Specific Requirements

... The works shall be carried out in accordance with the Office Electricity Act of Energy WA Electrical Requirements, AS/NZS 3000 Australia/New Zealand Wiring Rules, the requirement of Western Power, Synergy, Horizon or any other authority having jurisdiction over the installation (Power Supply Authori ...
Ballast OptiOns - Columbia Lighting
Ballast OptiOns - Columbia Lighting

... All factory-choice normal ballast factor electronic ballasts meet the following specifications. Optional ballast factors and customer specified vendor available as options. Ballast must be high power factor, (min. 95), Class P, UL listed, meet IEEE and ANSI requirements C62 .41 Category A for transi ...
Aalborg Universitet Klimczak, Pawel
Aalborg Universitet Klimczak, Pawel

... Thanks to CO2 emission reduction policies and increasing prices of fossil fuels a significant growth in field of sustainable energy sources (SES) is being observed during last decade. A government support and take-off projects in Europe and US shall ensure an increasing trend in future too. Some of ...
Aalborg Universitet SYSTEMS Choi, Uimin
Aalborg Universitet SYSTEMS Choi, Uimin

... It is divided into two main parts: the first part, which consists of Chapters 2 and 3, is reliability studies of the IGBT module regarding thermal stresses and the second part, composed of Chapters 4 and 5, discusses strategies to improve the reliability and availability of power electronic converte ...
multithreshold cmos sleep stack and logic stack technique for digital
multithreshold cmos sleep stack and logic stack technique for digital

... pMOS and nMO Stransistor. MTCMOS technique uses multiple voltages in the circuit which is the main advantage of this. Power dissipation, propagation delay and power delay product are calculated. Constrains like power, delay is compared with the existing techniques. It is proved that proposed techniq ...
Important notice Dear Customer, On 7 February 2017 the former
Important notice Dear Customer, On 7 February 2017 the former

... • Direct interface with TTL levels • Current drive ± 12 mA at 3.0 V • MULTIBYTETM flow-through standard pin-out architecture • Low inductance multiple VCC and GND pins for minimum noise ...
Fundamentals of Energy Efficient Lighting
Fundamentals of Energy Efficient Lighting

The Basics of Motor Selection
The Basics of Motor Selection

... and the field is the stationary component. Both the armature and field are wound with magnet wire and the electrical connection is made both to the armature (through the brushes) and the field. There are two characteristics that differentiate the Universal Motor from most other motor types making it ...
IEEE Draft Guide for the Specification of Fixed
IEEE Draft Guide for the Specification of Fixed

... This document is an unapproved draft of a proposed IEEE Standard. As such, this document is subject to change. USE AT YOUR OWN RISK! Because this is an unapproved draft, this document must not be utilized for any conformance/compliance purposes. Permission is hereby granted for IEEE Standards Commit ...
A Low-Voltage MOS Cascode Current Mirror for All Current Levels
A Low-Voltage MOS Cascode Current Mirror for All Current Levels

BDTIC
BDTIC

... In order to assure a proper shutdown sequence of all IGBTs in case of an under-voltage of the driver ICs, it is important to turn off the outer high side and the outer low side IGBTs first. There are two high voltage blocking diodes D3 and D12 each in series with the according +15V power line of the ...
< 1 ... 71 72 73 74 75 76 77 78 79 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.