• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
64-0030 Rev C (ME
64-0030 Rev C (ME

220/11 kV, 50 MVA and 25 MVA POWER TRANSFORMER
220/11 kV, 50 MVA and 25 MVA POWER TRANSFORMER

... of maximum harmonic voltage, especially the third and fifth so as to minimize interference with communication circuits. The noise level of transformer, when energized at normal voltage and frequency with fans and pumps running shall not exceed, when measured under standard conditions, the values spe ...
Some key facts about avalanche
Some key facts about avalanche

... avalanche current and/or energy. When the energy and current generated by such an event are low, the impact on the MOSFET is negligible. However, if avalanche induces either high energies or high currents, the MOSFET can be destroyed, as we shall see in section 2.2 when discussing the failure mechan ...
Yaskawa L1000 Quick Start Guide
Yaskawa L1000 Quick Start Guide

... shut off while the motor coasts to stop. Take the precautions described below to prevent shock and injury: • In applications where the machine can still rotate even though the drive has fully stopped a load, install a switch to the drive output side to disconnect the motor and the drive. • Do not al ...
EIB/KNX IP Router mit Power over Ethernet (PoE)
EIB/KNX IP Router mit Power over Ethernet (PoE)

MAX6335/MAX6336/MAX6337 4-Pin, Ultra-Low-Voltage, Low-Power µP Reset Circuits with Manual Reset General Description
MAX6335/MAX6336/MAX6337 4-Pin, Ultra-Low-Voltage, Low-Power µP Reset Circuits with Manual Reset General Description

... The MAX6335/MAX6336/MAX6337 microprocessor (µP) supervisory circuits monitor the power supplies in 1.8V to 3.3V µP and digital systems. They increase circuit reliability and reduce cost by eliminating external components and adjustments. They also feature a debounced manual-reset input. These device ...
AIM101
AIM101

... Describe ten basic rules of electrical safety Describe the purpose of the lockout/tagout system used in industry Describe the operation of three-phase power Describe the two most common three-phrase voltage systems Explain the function of neutral Describe two devices used to disconnect power to a ci ...
Instruction manual 850 Feeder Protection System
Instruction manual 850 Feeder Protection System

... Feeder protection and control ...
Oscillator Design and Computer Simulation
Oscillator Design and Computer Simulation

Mobile Intel Pentium 4 Processor with 533 MHz Front Side Bus
Mobile Intel Pentium 4 Processor with 533 MHz Front Side Bus

ATTENUATION MEASUREMENT
ATTENUATION MEASUREMENT

Developing an equipment SCCR standard for manufacturers of
Developing an equipment SCCR standard for manufacturers of

... or a more efficient busway (with lower impedance). A more common example is relocating existing equipment to another location where higher fault current exists. Any of the above may result in higher available fault current at the location where equipment is installed, which in turn may be larger tha ...
Intel® Atom™ Processor D400/D500 Series Datasheet, Vol. 1
Intel® Atom™ Processor D400/D500 Series Datasheet, Vol. 1

... definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information. The products described in this document may contain design defects ...
BDTIC www.BDTIC.com/infineon
BDTIC www.BDTIC.com/infineon

... The advent of industrial automation has seen several cycles of evolution, each time with significant advancement in ideas, design and technology. Today, systems based on semiconductors are exploited in almost every industrial application including sensing, control, robotics, communication, logistics ...
Power Transformer 115kV/12.47kV
Power Transformer 115kV/12.47kV

The Electrical, Thermal and Spatial Integration of a Converter in a
The Electrical, Thermal and Spatial Integration of a Converter in a

... to work in the exciting field of high power density, high temperature power electronics systems and for the financial support to make this Ph.D. thesis possible. I am also deeply grateful to you. My fascination with power electronics was and still is inspired by then my teacher, now my friend, Dr. I ...
8508A  Users Manual Reference Multimeter
8508A Users Manual Reference Multimeter

... Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or en ...
AS/ACIF S009:2006 - Communications Alliance
AS/ACIF S009:2006 - Communications Alliance

... intended to ensure the safety of customers, cabling providers, carrier staff, and the general public. However, cabling providers are reminded that metallic telecommunications conductors, earth connections, metallic parts, etc. may, at any given time, be at a voltage that exceeds the Telecommunicatio ...
Dual-Core Intel® Xeon® Processor 7100 Series
Dual-Core Intel® Xeon® Processor 7100 Series

- Magnum Dimensions
- Magnum Dimensions

AVR STK500 User Guide
AVR STK500 User Guide

... LEDn ...
Test, Tools, and Prototyping Section
Test, Tools, and Prototyping Section

Attachment
Attachment

... provided after the Contractor has completed the work and left at the site. Anchor bolts and/or other embedded steel/materials, if part of foundation pouring, required by the GIS Contractor for providing a level mounting surface for the GIS equipment and for mitigating ground potential rises around t ...
Adapting KMS for Custom Hardware
Adapting KMS for Custom Hardware

... In the TWR-MC-LV3PH reference hardware there are two sources of deadtime: the gate drive delay and the turn-on/turn-off time of the MOSFET. The gate drive used is the Freescale Semiconductor 33937A. According to the data sheet (Document Number: MC33937), there is a 265 ns delay between the time when ...
Carlo Gavazzi Product Overview
Carlo Gavazzi Product Overview

... Automation Components proximity sensors are measured against. Now in its fourth generation, TripleshieldTM provides outstanding electromagnetic immunity and protection against electrostatic discharge, surges and electrical noise from inverters, mobile phones, and contactors. Carlo Gavazzi cylindrica ...
< 1 ... 3 4 5 6 7 8 9 10 11 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report