• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrical Safety in Grounded, Resistance Grounded and
Electrical Safety in Grounded, Resistance Grounded and

... is usually in the high amp range and will force the over current device or the ground fault relay to trip the faulty circuit. It can get tricky when there is only one ground fault relay installed at the power source, protecting a multitude of circuits down the road. A typical situation is the roof m ...
installation manual
installation manual

... Lightning Surge Suppression Lightning does not actually need to strike the equipment or building where the PV system is installed to cause damage. Often, a strike nearby will induce voltage spikes in the electrical grid that can damage equipment. Darfon’s micro inverters have integral surge protecti ...
UJA1075A 1. General description High-speed CAN/LIN core system basis chip
UJA1075A 1. General description High-speed CAN/LIN core system basis chip

... • 250 mA voltage regulator for supplying a microcontroller; extendable with external PNP transistor for increased current capability and dissipation distribution ...
NBSG11 2.5V/3.3V SiGe 1:2 Differential Clock Driver with RSECL* Outputs
NBSG11 2.5V/3.3V SiGe 1:2 Differential Clock Driver with RSECL* Outputs

... NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared operating temperature range. Functiona ...
PAM8007
PAM8007

... Thermal protection on the PAM8007 prevents the device from damage when the internal die temperature exceeds +150°C. There is a 15 degree tolerance on this trip point from device to device. Once the die temperature exceeds the thermal set point, the device outputs are disabled. This is not a latched ...
Chapter 8: Reliability and Availability
Chapter 8: Reliability and Availability

... (F/hr), is not often used in practice due to its very small value for most normal components and systems. Instead, λ is more often expressed in terms of one of the following units. ...
Alpha Series Amplifier (Servo Amplifier Unit
Alpha Series Amplifier (Servo Amplifier Unit

... Note that installing more than one protection ground line with single screw makes it impossible for the motor to qualify for European CE marking. (See Appendix NO TAG.) ...
PT-24-45F Battery Charger
PT-24-45F Battery Charger

... When one or more of the available charger banks is not needed—if, for instance, you have only two battery banks—it is not necessary to jumper the output of that bank onto one of the others. Nor will you get additional charging by running a second wire from the extra bank to your load. The charger i ...
D-500 - datakom electronics engineering as
D-500 - datakom electronics engineering as

Mini-Vector AC Drive
Mini-Vector AC Drive

Eaton 9E
Eaton 9E

... Operation without Neutral may damage the unit. For installation with change in system earthing arrangement or galvanic isolation see below schematic ...
Chrysler and Jeep Data Parameters - Snap-on
Chrysler and Jeep Data Parameters - Snap-on

Installation Manual
Installation Manual

... The product operates at high voltages. All work on the product must be carried out by skilled persons only. ...
D4 HP Dimmer User’s Manual  Rev 1.01
D4 HP Dimmer User’s Manual Rev 1.01

Shaft Alternator Systems
Shaft Alternator Systems

... the PWM converter and the system control is adapted accordingly. With this configuration motor operation is provided as follows: n Booster propulsion operation parallel to the main engine to enlarge the propulsion power and the ship’s speed n Take home respectively take away propulsion opera ...
arduinoa
arduinoa

... int onTime = 2500; //the number of milliseconds for the motor to turn on for int offSpeed = 50; // a number between 0 (stopped) and 255 (full speed) int offTime = 1000; //the number of milliseconds for the motor to turn off for analogWrite(motorPin, onSpeed); // turns the motor On ...
20D-IN024 - Rockwell Automation
20D-IN024 - Rockwell Automation

... ATTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged before performing any work on the drive. Measure the DC bus voltage at the +DC and –DC terminals of the Power Terminal Block (refer to page 40 for location). The voltage must be zero. ATTENTION ...
spastyle - IEEE Standards working groups
spastyle - IEEE Standards working groups

... generally considered low energy transient overvoltages. Lightning surges are natural, caused by electrical discharge that occurs in the atmosphere between clouds or between clouds and ground. Lightning surges are known for causing very high energy transient overvoltages by direct or indirect couplin ...
viking-k2-manual
viking-k2-manual

... The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully as they contain important indications for the safe installation, use and maintenance. • These instruction must be kept and forwarded to all possible future users of the s ...
EN / ACS880-37 drives hardware manual
EN / ACS880-37 drives hardware manual

... Implementing thermal overload and short-circuit protection . . . . . . . . . . . . . . . . . . . . . . 84 Protecting the drive and input power cable in short-circuits . . . . . . . . . . . . . . . . . . . . 84 Protecting the motor and motor cable in short-circuits . . . . . . . . . . . . . . . . . . ...
S260-60-3
S260-60-3

... charged prior to shipment and is ready for use. Temperature has an effect on battery life. Sealed lead acid batteries should be stored, fully charged, at room temperature. Never store lead acid batteries at temperatures exceeding 47 °C (117 °F), as damage can result in approximately one month. ...
3. Rated voltage and short-time withstand current
3. Rated voltage and short-time withstand current

... various LV elements required for the operation of the motor mechanism and auxiliary equipment. For specific needs, it shall be possible to enlarge or extend the LV box by adding an enclosure with a door to the top of the cubicle. The overall height of the cubicles shall not exceed 2225 mm. In all ca ...
59512 Hydro E-03-333 S4NVX
59512 Hydro E-03-333 S4NVX

... For use with product built with Regal Beloit/Marathon motor. ORDERING REPLACEMENT PARTS: Product improvements are made from time to time. The latest part design will be furnished as long as it is interchangeable with the old part.When ordering replacement parts, always furnish the following informat ...
Mobius Microsystems CICC Talk
Mobius Microsystems CICC Talk

PIR Motion Sensor
PIR Motion Sensor

... Panasonic develops and produces PIR Motion sensors, which combine easy integration, high reliability and environment-friendly materials. The Panasonic PIR Motion sensors abbreviated as PaPIRs, has three series of products, including - EKMB(WL)with low current consumption - EKMC(VZ)for general use - ...
< 1 ... 55 56 57 58 59 60 61 62 63 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.