Golden Rules for Low Emission
... • Cdec: the minimum capacitor able to provide a current to the circuit without any large voltage fluctuations. • ΔVddmax : max allowed voltage fluctuation • ΔI : current peak absorbed by the circuit • tr : rise time of the current peak ...
... • Cdec: the minimum capacitor able to provide a current to the circuit without any large voltage fluctuations. • ΔVddmax : max allowed voltage fluctuation • ΔI : current peak absorbed by the circuit • tr : rise time of the current peak ...
Axial Flux Permanent Magnet Generator Design for
... generator output voltage Vcut-in must be equal to the batteries’ voltage Vbatt i.e. Vcut-in = Vbatt. This happens when the wind rises to the cut-in wind speed vwcut-in. This wind speed is frequently set at 3 m/s for rural and residential applications, both in open source hardware designs as in [4] a ...
... generator output voltage Vcut-in must be equal to the batteries’ voltage Vbatt i.e. Vcut-in = Vbatt. This happens when the wind rises to the cut-in wind speed vwcut-in. This wind speed is frequently set at 3 m/s for rural and residential applications, both in open source hardware designs as in [4] a ...
Training Agenda
... Depending on geography, the level of primary protection provided in the MDF varies. In certain regions of the world the effects of lightning can be more severe. In these cases, the MDF module will need a surge rating of several thousand Amperes (KA); the solution here is to use a Gas Plasma device. ...
... Depending on geography, the level of primary protection provided in the MDF varies. In certain regions of the world the effects of lightning can be more severe. In these cases, the MDF module will need a surge rating of several thousand Amperes (KA); the solution here is to use a Gas Plasma device. ...
Section 3 GDT Telecom Applications Protection Examples
... Depending on geography, the level of primary protection provided in the MDF varies. In certain regions of the world the effects of lightning can be more severe. In these cases, the MDF module will need a surge rating of several thousand Amperes (KA); the solution here is to use a Gas Plasma device. ...
... Depending on geography, the level of primary protection provided in the MDF varies. In certain regions of the world the effects of lightning can be more severe. In these cases, the MDF module will need a surge rating of several thousand Amperes (KA); the solution here is to use a Gas Plasma device. ...
General technical information
... B9- Permissible AC Voltage up to 60Hz It is the pure sine wave voltage that may be applied to the capacitor at a frequency up to 60Hz. The dissipated power and currents must be considered in case of operation at higher frequency. The AC rated voltages stated for each series refer to an operating fre ...
... B9- Permissible AC Voltage up to 60Hz It is the pure sine wave voltage that may be applied to the capacitor at a frequency up to 60Hz. The dissipated power and currents must be considered in case of operation at higher frequency. The AC rated voltages stated for each series refer to an operating fre ...
An adaptive high speed PMSM control for electric vehicle application
... Synchronous Motors (PMSM) drives are the most competitors to the other. Due to its superior advantages such as high efficiency, low inertia, high torque to current ratio, high power factor, smaller size, lower weight and almost no need for maintenance, makes it more preferable face to the other moto ...
... Synchronous Motors (PMSM) drives are the most competitors to the other. Due to its superior advantages such as high efficiency, low inertia, high torque to current ratio, high power factor, smaller size, lower weight and almost no need for maintenance, makes it more preferable face to the other moto ...
AN-608 APPLICATION NOTE
... frequency, differential input voltage, and capacitor size, but in general the average current increases for higher performance (lower noise) ADCs. The average current required on these parts is typically 125 nA/V, but if the PGA is on a range setting other than 2.56 V, the required current increase ...
... frequency, differential input voltage, and capacitor size, but in general the average current increases for higher performance (lower noise) ADCs. The average current required on these parts is typically 125 nA/V, but if the PGA is on a range setting other than 2.56 V, the required current increase ...
CSI 16610 Uninterruptible Power Supply Systems
... K. On Bypass connection: The UPS shall provide a built-in landing for field connection to a maintenance bypass switch. This connection will insure the UPS is in bypass mode prior to switching to the maintenance bypass switch. L. Input Line Cord or Hardwired to utility: The UPS can be ordered with a ...
... K. On Bypass connection: The UPS shall provide a built-in landing for field connection to a maintenance bypass switch. This connection will insure the UPS is in bypass mode prior to switching to the maintenance bypass switch. L. Input Line Cord or Hardwired to utility: The UPS can be ordered with a ...
AD9744 数据手册DataSheet 下载
... The AD97441 is a 14-bit resolution, wideband, third generation member of the TxDAC series of high performance, low power CMOS digital-to-analog converters (DACs). The TxDAC family, consisting of pin-compatible 8-, 10-, 12-, and 14-bit DACs, is specifically optimized for the transmit signal path of c ...
... The AD97441 is a 14-bit resolution, wideband, third generation member of the TxDAC series of high performance, low power CMOS digital-to-analog converters (DACs). The TxDAC family, consisting of pin-compatible 8-, 10-, 12-, and 14-bit DACs, is specifically optimized for the transmit signal path of c ...
Paper Title (use style: paper title)
... transistor is used so that this transistor supplies a small current from the supply to the dynamic node. Therefore charge stored is preserved for the needed conditions. Current contention is also a serious problem. By disabling the keeper for particular amount of time temporarily during the dynamic ...
... transistor is used so that this transistor supplies a small current from the supply to the dynamic node. Therefore charge stored is preserved for the needed conditions. Current contention is also a serious problem. By disabling the keeper for particular amount of time temporarily during the dynamic ...
MLCC Technology Advances Open New Market Opportunities
... In high-frequency applications, particularly ones with a large high-frequency current running through the MLCC, a high-Q factor is required to reduce power dissipated by the MLCC. Applications for high-Q MLCCs include cellular base stations, telecommunication networks, TV set-top boxes, and GPS devi ...
... In high-frequency applications, particularly ones with a large high-frequency current running through the MLCC, a high-Q factor is required to reduce power dissipated by the MLCC. Applications for high-Q MLCCs include cellular base stations, telecommunication networks, TV set-top boxes, and GPS devi ...
Industry's Smallest 1.55A 1-Cell Li+ DC-DC Charger General Description Benefits and Features
... battery from inputs up to 7.5V and withstands transient inputs up to 22V. The 4MHz switch-mode charger is ideally suited for small portable devices, such as headsets and ultra-portable media players. It minimizes component size and heat. Battery-protection features include: low-voltage prequalificat ...
... battery from inputs up to 7.5V and withstands transient inputs up to 22V. The 4MHz switch-mode charger is ideally suited for small portable devices, such as headsets and ultra-portable media players. It minimizes component size and heat. Battery-protection features include: low-voltage prequalificat ...
ultra-precision differential cml line driver/receiver with
... The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not desi ...
... The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not desi ...
Artificial Muscle
... scaling, contraction/elongation degree of freedom. 1. Piezoelectric actuators were first heavily researched after World War 2 and today are commonly available over the counter. The most common form of piezoelectric actuator is based on a lead zirconate titanate (PZT) material which is a ceramic comp ...
... scaling, contraction/elongation degree of freedom. 1. Piezoelectric actuators were first heavily researched after World War 2 and today are commonly available over the counter. The most common form of piezoelectric actuator is based on a lead zirconate titanate (PZT) material which is a ceramic comp ...
What is the loop
... When an appliance is connected to the mains supply a circuit is made. It completes the loop current flow round the circuit loop from the power station in the live wire through the appliance and then back to the power station in the neutral wire. Voltage is dropped around the loop due to the resistan ...
... When an appliance is connected to the mains supply a circuit is made. It completes the loop current flow round the circuit loop from the power station in the live wire through the appliance and then back to the power station in the neutral wire. Voltage is dropped around the loop due to the resistan ...
Software-Selectable, Half-/Full-Duplex, Slew-Rate-Limited, 12Mbps, RS-485/RS-422 Transceivers in µMAX Package
... All parts contain one driver and one receiver and feature a 1/8-unit-load receiver input impedance, allowing up to 256 transceivers on the bus. The MAX1481/ MAX1485 feature reduced-slew-rate drivers that minimize EMI and reduce reflections caused by improperly terminated cables, allowing error-free ...
... All parts contain one driver and one receiver and feature a 1/8-unit-load receiver input impedance, allowing up to 256 transceivers on the bus. The MAX1481/ MAX1485 feature reduced-slew-rate drivers that minimize EMI and reduce reflections caused by improperly terminated cables, allowing error-free ...
mv motor control centers fvnr spec
... three padlocks in the on or off position. [A changeover contact shall be provided for remote position indication of the disconnector.] [Provide key interlocks to coordinate with….] 2.4.1.1 Mechanical Interlocks: interlock shall be provided to prevent the opening of the high voltage access door with ...
... three padlocks in the on or off position. [A changeover contact shall be provided for remote position indication of the disconnector.] [Provide key interlocks to coordinate with….] 2.4.1.1 Mechanical Interlocks: interlock shall be provided to prevent the opening of the high voltage access door with ...
3-in-1 Current Transformers
... A range of 3-in-1 current transformers combine three traditional current transformers in one moulded case. 3-in-1 current transformers can be directly installed next to a three-phase moulded case circuit breaker, thus saving installation time where fitting three standard individual current transform ...
... A range of 3-in-1 current transformers combine three traditional current transformers in one moulded case. 3-in-1 current transformers can be directly installed next to a three-phase moulded case circuit breaker, thus saving installation time where fitting three standard individual current transform ...
S225-20-1
... control to be mounted remote from the unit. Included in the kit are a 6-conductor neoprene-coveredcable and pole-mountingbracket. Control cable length can be 3, 9, 12,15,20, or 30 feet. NOTE: Disconnectingthe control from an Auto-Booster regulator in servicehas no effect on the unit or system voltag ...
... control to be mounted remote from the unit. Included in the kit are a 6-conductor neoprene-coveredcable and pole-mountingbracket. Control cable length can be 3, 9, 12,15,20, or 30 feet. NOTE: Disconnectingthe control from an Auto-Booster regulator in servicehas no effect on the unit or system voltag ...