
FEATURES DESCRIPTION
... these last three bits. This byte is called the Hs master code. (Note that this is different from normal address bytes—the low bit does not indicate read/write status.) The BUF08800 does not acknowledge this byte; the communication protocol prohibits acknowledgment of the Hs master code. On receiving ...
... these last three bits. This byte is called the Hs master code. (Note that this is different from normal address bytes—the low bit does not indicate read/write status.) The BUF08800 does not acknowledge this byte; the communication protocol prohibits acknowledgment of the Hs master code. On receiving ...
Real-Time Recognition Non-Intrusive Electrical Appliance
... To this end, building energy management that could detect and monitor individual appliance energy consumption is essential and paramount to any effective energy management system. There are basically two approaches of monitoring appliances energy consumption in buildings: Intrusive appliance load mo ...
... To this end, building energy management that could detect and monitor individual appliance energy consumption is essential and paramount to any effective energy management system. There are basically two approaches of monitoring appliances energy consumption in buildings: Intrusive appliance load mo ...
EFRATOM LPRO 101 Repair Guide
... It you tried turning the lamp assembly trimmer in order to increase lamp volt, you could have "forced" it causing the rotation of its hot (not ground) lead and possible short on the coil inside the lamp assembly. I would say all 100k resistors of this size on the board are suspect. They are of the 0 ...
... It you tried turning the lamp assembly trimmer in order to increase lamp volt, you could have "forced" it causing the rotation of its hot (not ground) lead and possible short on the coil inside the lamp assembly. I would say all 100k resistors of this size on the board are suspect. They are of the 0 ...
Evaluate: MAX1316–MAX1327 MAX1320 Evaluation Kit/Evaluation System General Description Features
... two’s complement (or offset binary in unipolar devices) to signed decimal. The raw data can be saved to a text file using the Save… menu item in the graph window. ...
... two’s complement (or offset binary in unipolar devices) to signed decimal. The raw data can be saved to a text file using the Save… menu item in the graph window. ...
MAX1838 Dual USB Switch with Fault Blanking and Autoreset General Description
... Dual USB Switch with Fault Blanking and Autoreset The MAX1838 is a dual, current-limited USB switch with auxiliary input supply. Each switch meets all IEC specifications for USB ports and is guaranteed to supply 500mA from either of two input supplies. A control pin selects the power source from eit ...
... Dual USB Switch with Fault Blanking and Autoreset The MAX1838 is a dual, current-limited USB switch with auxiliary input supply. Each switch meets all IEC specifications for USB ports and is guaranteed to supply 500mA from either of two input supplies. A control pin selects the power source from eit ...
L V E
... NEMA 4. Typical outdoor applications shall be NEMA 3R. In cooling towers, parking structures, or areas where water spray and/or high humidity will be present, use stainless steel NEMA 4. For other special locations, provide equipment that has NEMA type enclosures as required by the NEC. Panelboards ...
... NEMA 4. Typical outdoor applications shall be NEMA 3R. In cooling towers, parking structures, or areas where water spray and/or high humidity will be present, use stainless steel NEMA 4. For other special locations, provide equipment that has NEMA type enclosures as required by the NEC. Panelboards ...
AD5063 数据手册DataSheet 下载
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ab ...
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ab ...
On board diagnosis of pre-supply fuel pump control Module with
... category of vehicle and its usage. Pre supply fuel pump comes with the common rail system it pumps the fuel from fuel tank to the high pressure pump inlet. This paper discuss about the on board diagnosis provided in a pump driver module which has two power transistors used as switching elements for ...
... category of vehicle and its usage. Pre supply fuel pump comes with the common rail system it pumps the fuel from fuel tank to the high pressure pump inlet. This paper discuss about the on board diagnosis provided in a pump driver module which has two power transistors used as switching elements for ...
Ionizer Nozzle type
... Note 1) Measured with a probe of 1000 MΩ and 5 pF. Note 2) Measured with a distance of 100 mm between the charged object and ionizer at an air purge pressure of 0.3 MPa. For the static neutralization time, refer to technical data on page 1129. Note 3) Value above background level, measured with a di ...
... Note 1) Measured with a probe of 1000 MΩ and 5 pF. Note 2) Measured with a distance of 100 mm between the charged object and ionizer at an air purge pressure of 0.3 MPa. For the static neutralization time, refer to technical data on page 1129. Note 3) Value above background level, measured with a di ...
Series 71, 72, and 76 Modutrol IV™ Motors
... Electrically Normally Closed: Both spring return and nonspring motors return to closed position on minimum signal. ...
... Electrically Normally Closed: Both spring return and nonspring motors return to closed position on minimum signal. ...
LP2998/LP2998-Q1 DDR Termination
... Therefore, to calculate the total power loss in shutdown both currents need to be considered. For more information refer to the Thermal Dissipation section. The shutdown pin also has an internal pull-up current, therefore to turn the part on the shutdown pin can either be connected to AVIN or left o ...
... Therefore, to calculate the total power loss in shutdown both currents need to be considered. For more information refer to the Thermal Dissipation section. The shutdown pin also has an internal pull-up current, therefore to turn the part on the shutdown pin can either be connected to AVIN or left o ...
ARCCOM Installation and Operation Manual
... The ARCCOM is a commercial disconnecting fused string combiner designed for combining multiple strings of photovoltaic (PV) modules for connection to an inverter. In a large PV array, each string of PV modules must be fused before being paralleled and connected to an inverter. The ARCCOM String Comb ...
... The ARCCOM is a commercial disconnecting fused string combiner designed for combining multiple strings of photovoltaic (PV) modules for connection to an inverter. In a large PV array, each string of PV modules must be fused before being paralleled and connected to an inverter. The ARCCOM String Comb ...
HPM10 - Power Management IC for Hearing Aids
... battery from over discharge ♦ DSP detects low battery voltage and puts HPM10 in Deep Sleep Mode through the DS_EN pin In all modes, when the device is removed from the cradle, it will either immediately turn on or wait until the pushbutton is pushed. This means that for the first and second use case ...
... battery from over discharge ♦ DSP detects low battery voltage and puts HPM10 in Deep Sleep Mode through the DS_EN pin In all modes, when the device is removed from the cradle, it will either immediately turn on or wait until the pushbutton is pushed. This means that for the first and second use case ...
Series VDW - SMC ETech
... 20°C and when the rated voltage is applied. (Variation: ±10%) Note 2) There is no difference in the frequency and the inrush and energized apparent power, since a rectifying circuit is used in the AC (with a full wave rectifier). Note 3) The value at ambient temperature of 20°C and when the rated vo ...
... 20°C and when the rated voltage is applied. (Variation: ±10%) Note 2) There is no difference in the frequency and the inrush and energized apparent power, since a rectifying circuit is used in the AC (with a full wave rectifier). Note 3) The value at ambient temperature of 20°C and when the rated vo ...