• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Emergency Power System
Emergency Power System

... to determine the amperage the load will draw from the batteries. ...
new approaches to the direct measurement of capacitance
new approaches to the direct measurement of capacitance

ADS5271 数据资料 dataSheet 下载
ADS5271 数据资料 dataSheet 下载

... Analog Input Common-Mode Range Differential Full-Scale Input Voltage Range ...
SECTION – III STEP UP SUBSTATION
SECTION – III STEP UP SUBSTATION

... device. The best protection is provided by modern type (gapless) lightning arrestors. The spread margin between the BIL and the protective device, allowing for manufacturing tolerance, is an economic consideration that must balance the chances of insulation failure against the cost of greater insula ...
Electrical Overstress Damage of TI 1394 PHY
Electrical Overstress Damage of TI 1394 PHY

... likely to see late Vg damage. A late Vg event cannot occur on a 1394 node where only a 4connection (TPA, TPA*, TPB, TPB*) receptacle is used. If there is no Vp connection, by extension there can be no damage. In addition, self-powered applications (a system that never sources or sinks current from t ...
Fluke 5101B Calibration Procedure Board A17
Fluke 5101B Calibration Procedure Board A17

... control path. A "GND-Isolation-Transfer" Circuit, that is transferring the control voltage from GND(F) to GND(S), is totally different. This is probably the reason why the control voltages can differ slightly from those who are considered in the original Fluke manual. In case of alignment of R17, I ...
ADAPTIVE RESISTANCE CONTROL SOLUTIONS IN AN ASSISTED CODING ENVIRONMENT
ADAPTIVE RESISTANCE CONTROL SOLUTIONS IN AN ASSISTED CODING ENVIRONMENT

AT 121 - Chapter 2 - Basic Electrical Principals
AT 121 - Chapter 2 - Basic Electrical Principals

... On Car Starter Motor Inspection – Customer Complaint – “Poor Crank, or Intermittent Crank” If a starter does not run, and the battery checks out, this simple test may be preformed on any vehicle. The test is broken down to inspect the most basic parts of a starter circuit. Proper power and ground ...
Bipolar Junction Transistor - Corporate Group of Institutes
Bipolar Junction Transistor - Corporate Group of Institutes

... • The comprises of two components – the majority and minority carriers IC = ICmajority + ICOminority • ICO – IC current with emitter terminal open and is called leakage current. ...
A New Interleaved Three-Phase Single-Stage
A New Interleaved Three-Phase Single-Stage

... A New Interleaved Three-Phase Single-Stage PFC AC-DC Converter with Flying Capacitor Abstract: In this project, a new interleaved three-phase PFC AC-DC single-stage multilevel converter is contemplated. The suggested converter can operate with reduced input current ripple and peak switch currents du ...
II. Excitation System
II. Excitation System

... Exciter is the source of electrical power for the field winding of generator and is realized as a separate DC or AC generator. Exciter has its field winding in the stator, and armature winding in the rotor. In case of AC generator, as the rotor rotates, stator DC current induces a three-phase altern ...
XFR600-2 Operating Manual
XFR600-2 Operating Manual

ROKIT POWERED SERIES NEAR FIELD STUDIO MONITOR
ROKIT POWERED SERIES NEAR FIELD STUDIO MONITOR

MAXQ8913 16-Bit, Mixed-Signal Microcontroller with Op Amps, General Description
MAXQ8913 16-Bit, Mixed-Signal Microcontroller with Op Amps, General Description

... Note 15: Devices that use nonstandard supply voltages that do not conform to the intended I2C-bus system levels must relate their input levels to the VDVDD voltage to which the pullup resistors RP are connected. Note 16: Maximum VIH_I2C = VDVDD(MAX) + 0.5V. Note 17: CB = capacitance of one bus line ...
PDF (Publisher`s version)
PDF (Publisher`s version)

... allows for comparing differently sized circuits fairly, similar to normalizing oscillator phase noise or filter SNR to power. In [7], DTG FFs (DTG-FFs) were used and able to achieve very low phase errors at much lower power consumption than CML. Explorative simulations in [10] confirmed that DTGFFs ...
Cooper: Form 6 Part 2
Cooper: Form 6 Part 2

Stepnet Micro Module
Stepnet Micro Module

Deenergizing Electrical Equipment
Deenergizing Electrical Equipment

... shall be returned to its operable condition when this work is completed. Use of Equipment (a) Portable electric equipment. This paragraph applies to the use of cord- and plug-connected equipment, including flexible cord sets (extension cords). (a) (1) Handling. Portable equipment shall be handled in ...
QCL FAQ List
QCL FAQ List

Design and  Simulation of a  Graphene DEPFET Detector
Design and Simulation of a Graphene DEPFET Detector

Wind turbine power generation emulation via doubly fed induction
Wind turbine power generation emulation via doubly fed induction

... specified parameters. For the Supply-side circuit we use the mentioned sensed inputs to derive control of VDC so that it is maintained at 200V via SVM. There is also a built-in protection feature in the Supply-side circuit that will turn off the SVM if a VDC of 240V is reached. The DFIG circuit powe ...
Monitoring of electrical equipment failure indicators and zero
Monitoring of electrical equipment failure indicators and zero

... creates greater heat during normal operating conditions and this additional heat can deteriorate the lubricants required for proper circuit breaker mechanical operation. Another example is insulation resistance of electrical distribution equipment, as well as gas-in-oil testing results for transform ...
Conductive Polymer Aluminum Solid Electrolytic Capacitors "PZ
Conductive Polymer Aluminum Solid Electrolytic Capacitors "PZ

... Conductive Polymer Aluminum Solid Electrolytic Capacitors "PZ-CAP" Introduction Under the concern on depletion of global resources due to global warming, radical growth of developing countries and population increase in cities and developing countries, effective utilization of energy is becoming to ...
IGBT Driver Calculation
IGBT Driver Calculation

... t2 switching interval: VGE maintains VGE(pl). When the free-wheeling diode is turned-off, VCE starts to drop rapidly and dvCE/dt is high. t3 switching interval: While VCE is decreasing to reach on-state value VCEsat, the Miller capacitance CGC increases as the voltage decreases and is charged by IG. ...
LMV1099 数据资料 dataSheet 下载
LMV1099 数据资料 dataSheet 下载

< 1 ... 200 201 202 203 204 205 206 207 208 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report