
MAX5550 Dual, 10-Bit, Programmable, 30mA High-Output-Current DAC General Description
... for PIN diode biasing applications. Outputs can also be paralleled for high-current applications (up to 60mA typ). Operating from a single +2.7V to +5.25V supply, the MAX5550 typically consumes 1.5mA per DAC in normal operation and less than 1µA (max) in shutdown mode. The MAX5550 also features low ...
... for PIN diode biasing applications. Outputs can also be paralleled for high-current applications (up to 60mA typ). Operating from a single +2.7V to +5.25V supply, the MAX5550 typically consumes 1.5mA per DAC in normal operation and less than 1µA (max) in shutdown mode. The MAX5550 also features low ...
electronics 1 - Computer Engineering 2009
... A safety device which will 'blow' (melt) if the current flowing through it exceeds a specified value. ...
... A safety device which will 'blow' (melt) if the current flowing through it exceeds a specified value. ...
GS-12-1278
... TX output power measurement is based on internal monitor diode feedback. Represented as a 16-bit unsigned integer with the power defined as the full 16 bit value (0 – 65535) with LSB equal to 0.1 μW. Accuracy is better than +/-3 dB over a range of Pavgmin to Pavgmax. Copyright © 2015 FCI Deutschland ...
... TX output power measurement is based on internal monitor diode feedback. Represented as a 16-bit unsigned integer with the power defined as the full 16 bit value (0 – 65535) with LSB equal to 0.1 μW. Accuracy is better than +/-3 dB over a range of Pavgmin to Pavgmax. Copyright © 2015 FCI Deutschland ...
S.T.A.R. PATHFINDER variable trip test point faulted circuit indicators
... A long-life Lithium Ion battery provides power to indicate the faulted conditions using a high intensity light-emitting diode (LED) display. The unit will flash for a period of four hours after a fault has occurred. After the four hour period, the LED will stop flashing to conserve battery power; ho ...
... A long-life Lithium Ion battery provides power to indicate the faulted conditions using a high intensity light-emitting diode (LED) display. The unit will flash for a period of four hours after a fault has occurred. After the four hour period, the LED will stop flashing to conserve battery power; ho ...
TPS84250 Evaluation Module User Guide (Rev
... Communications Commission (FCC) and Industry Canada (IC) rules. For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for genera ...
... Communications Commission (FCC) and Industry Canada (IC) rules. For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for genera ...
Digitax ST Tech Data Iss2.book
... certified to the International Standard ISO 14001. Further information on the EMS, our Environmental Policy and other relevant information is available on request, or can be found at www.greendrives.com. The electronic variable-speed drives manufactured by Control Techniques have the potential to sa ...
... certified to the International Standard ISO 14001. Further information on the EMS, our Environmental Policy and other relevant information is available on request, or can be found at www.greendrives.com. The electronic variable-speed drives manufactured by Control Techniques have the potential to sa ...
Q2406/Q2426 Customer Design Guide_rev007
... (battery+contacts+protections+PCB) should be < 150 mΩ to limit voltage dropout within emission burst. As the radio power amplifier is directly connected to VBATT, the module is sensitive to any Alternative Current on lines. When a DC/DC converter is used, Wavecom recommends to set the converter freq ...
... (battery+contacts+protections+PCB) should be < 150 mΩ to limit voltage dropout within emission burst. As the radio power amplifier is directly connected to VBATT, the module is sensitive to any Alternative Current on lines. When a DC/DC converter is used, Wavecom recommends to set the converter freq ...
Classic Mac Repair Notes
... years, most are), take it out and replace it with a fresh one before doing the clean. After a clean, replace all of the electrolytic capacitors if you want to do a good job. It’s not that hard (but it is tedious), and if you want that Mac to live on for many more years, replacement of all of the ele ...
... years, most are), take it out and replace it with a fresh one before doing the clean. After a clean, replace all of the electrolytic capacitors if you want to do a good job. It’s not that hard (but it is tedious), and if you want that Mac to live on for many more years, replacement of all of the ele ...
Feedforward-Regulated Cascode OTA for Gigahertz Applications
... Abstract—A very high-frequency operational transconductance amplifier (OTA) with a new feedforward-regulated cascode topology is demonstrated in this paper. Experimental results show a bandwidth of 10 GHz and a large transconductance of 11 mS. A theoretical analysis of the OTA is provided which is i ...
... Abstract—A very high-frequency operational transconductance amplifier (OTA) with a new feedforward-regulated cascode topology is demonstrated in this paper. Experimental results show a bandwidth of 10 GHz and a large transconductance of 11 mS. A theoretical analysis of the OTA is provided which is i ...
TSMC: Advanced Design for Low Power at 65nm and Below
... CPF quality checking helps eliminate errors in the CPF. Three critical areas for checking include: • Logic equivalence checking (LEC) ensures that low-power optimizations do not introduce logical errors; enables true EC leveraging CPF; checks state retention mapping from RTL to gate; checks corresp ...
... CPF quality checking helps eliminate errors in the CPF. Three critical areas for checking include: • Logic equivalence checking (LEC) ensures that low-power optimizations do not introduce logical errors; enables true EC leveraging CPF; checks state retention mapping from RTL to gate; checks corresp ...
AN10713 18 W CFL lamp design using UBA2024 application
... area by personnel qualified according to local requirements and labor laws to work with non-insulated mains voltages and high-voltage circuits. This product shall never be operated unattended. ...
... area by personnel qualified according to local requirements and labor laws to work with non-insulated mains voltages and high-voltage circuits. This product shall never be operated unattended. ...
NX3P190 1. General description Logic controlled high-side power switch
... The NX3P190 is a high-side load switch which features a low ON resistance P-channel MOSFET that supports more than 500 mA of continuous current. Designed for operation from 1.1 V to 3.6 V, it is used in power domain isolation applications to reduce power dissipation and extend battery life. The enab ...
... The NX3P190 is a high-side load switch which features a low ON resistance P-channel MOSFET that supports more than 500 mA of continuous current. Designed for operation from 1.1 V to 3.6 V, it is used in power domain isolation applications to reduce power dissipation and extend battery life. The enab ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... monitoring techniques and is inexpensive as electrical sensors are lower in cost compared to mechanical transducers. Condition monitoring is defined as the continuous evaluation of the health of the plant and equipment throughout its service life. It is used to detect various types of faults such ...
... monitoring techniques and is inexpensive as electrical sensors are lower in cost compared to mechanical transducers. Condition monitoring is defined as the continuous evaluation of the health of the plant and equipment throughout its service life. It is used to detect various types of faults such ...
LP324, LP2902 ULTRA-LOW-POWER QUADRUPLE OPERATIONAL AMPLIFIERS FEATURES
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
OUR PHILOSOPHY ON AMP MODIFICATIONS One of the most
... Vacuum tube technology operates at high voltages. Therefore, it is VERY DANGEROUS. A very real risk is damaging or destroying your amp. If that is not bad enough, you can seriously damage or destroy YOURSELF. The moral is: always make sure that any work done on your amp is done by a qualified techni ...
... Vacuum tube technology operates at high voltages. Therefore, it is VERY DANGEROUS. A very real risk is damaging or destroying your amp. If that is not bad enough, you can seriously damage or destroy YOURSELF. The moral is: always make sure that any work done on your amp is done by a qualified techni ...
Quasi-resonant control with XMC1000
... As the PFC load gets lower, the ON-time gets shorter in order to maintain constant output voltage. As a result, the average switching frequency of the PFC increases. Although switching loss has been greatly reduced by using a quasi-resonant mode, it will increase again as the switching frequency inc ...
... As the PFC load gets lower, the ON-time gets shorter in order to maintain constant output voltage. As a result, the average switching frequency of the PFC increases. Although switching loss has been greatly reduced by using a quasi-resonant mode, it will increase again as the switching frequency inc ...
HYPERTHERM SENSOR™ PHC PLASMA HEIGHT CONTROL
... 3) Suitable for use on a circuit capable of delivering not more than 5000rms symmetrical amperes, 230 volts maximum. 4) Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection provided by integral LISTED branch circuit protection fuse. ...
... 3) Suitable for use on a circuit capable of delivering not more than 5000rms symmetrical amperes, 230 volts maximum. 4) Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection provided by integral LISTED branch circuit protection fuse. ...
Lecture 13
... – To reduce electronic noise during signal acquisition, the output stage of an RFPA are shut off – Delay measures the ability of an RFPA to rapidly turn on/off – Specification for MRI: 2 μsec G16.4427 Practical MRI 1 – 16th April 2015 ...
... – To reduce electronic noise during signal acquisition, the output stage of an RFPA are shut off – Delay measures the ability of an RFPA to rapidly turn on/off – Specification for MRI: 2 μsec G16.4427 Practical MRI 1 – 16th April 2015 ...
Lambert, S 13 - Newcastle University eTheses
... between the cells results in voltage mismatch across the stack. Mismatched voltages are an inefficient use of the energy storage medium and can lead to dangerous failures in the cells. Several techniques exist to limit the variance in cell voltages of supercapacitors across a series connected stack. ...
... between the cells results in voltage mismatch across the stack. Mismatched voltages are an inefficient use of the energy storage medium and can lead to dangerous failures in the cells. Several techniques exist to limit the variance in cell voltages of supercapacitors across a series connected stack. ...
MAX3320A/B/L/T 3V to 5.5V, up to 250kbps True RS
... Tables 1 and 2 and Figure 2 summarize the MAX3320’s operating modes. FORCEON and FORCEOFF override the automatic circuitry and force the transceiver into its normal operating state or into its low-power standby state. When neither control is asserted, the IC enters AutoShutdown Plus mode and selects ...
... Tables 1 and 2 and Figure 2 summarize the MAX3320’s operating modes. FORCEON and FORCEOFF override the automatic circuitry and force the transceiver into its normal operating state or into its low-power standby state. When neither control is asserted, the IC enters AutoShutdown Plus mode and selects ...
Meta-parametrised meta-modelling approach for
... Example of relationship between inductor winding losses and overall volume for three different inductor technologies from the manufacturer Siemens. The three-phase reactor series 4EUXX with a Cu or Al winding conductor, and the DC iron core smoothing reactor series 4ETXX with a Cu winding conductor ...
... Example of relationship between inductor winding losses and overall volume for three different inductor technologies from the manufacturer Siemens. The three-phase reactor series 4EUXX with a Cu or Al winding conductor, and the DC iron core smoothing reactor series 4ETXX with a Cu winding conductor ...