STN9360
... This device is a high voltage fast-switching PNP power transistor. It is manufactured using high voltage multi epitaxial planar technology for high switching speeds and medium voltage capability. It uses a cellular emitter structure with planar edge termination to enhance switching speeds while main ...
... This device is a high voltage fast-switching PNP power transistor. It is manufactured using high voltage multi epitaxial planar technology for high switching speeds and medium voltage capability. It uses a cellular emitter structure with planar edge termination to enhance switching speeds while main ...
PDF Version(51KB)
... with four wireless frequency bands used commonly in Asia including Japan, the United States, Europe and other countries. Compatible with both W-CDMA and LTE network systems, the BA012M1 is a downsized power amplifier that will enable smaller-sized mobile devices. The initial production volume is thr ...
... with four wireless frequency bands used commonly in Asia including Japan, the United States, Europe and other countries. Compatible with both W-CDMA and LTE network systems, the BA012M1 is a downsized power amplifier that will enable smaller-sized mobile devices. The initial production volume is thr ...
2SB1731
... third party's intellectual property rights or other proprietary rights, and further, assumes no liability of whatsoever nature in the event of any such infringement, or arising from or connected with or related to the use of such devices. Upon the sale of any such devices, other than for buyer's rig ...
... third party's intellectual property rights or other proprietary rights, and further, assumes no liability of whatsoever nature in the event of any such infringement, or arising from or connected with or related to the use of such devices. Upon the sale of any such devices, other than for buyer's rig ...
glossary of power terms
... Distortion factor (%DF) — Total harmonic Distortion referenced to the total RMS signal (THD-R). Distortion power factor — the difference between apparent power and true power at all harmonic frequencies. Frequency — the number of complete cycles of AC voltage which occurs during one second (Hz). Har ...
... Distortion factor (%DF) — Total harmonic Distortion referenced to the total RMS signal (THD-R). Distortion power factor — the difference between apparent power and true power at all harmonic frequencies. Frequency — the number of complete cycles of AC voltage which occurs during one second (Hz). Har ...
Q: Are the LED Downlights available in low voltage
... A: YES, Cantalupi USA has a turnkey lighting control system using the latest technology in Touch Screen PLC systems. The system is capable of but not limited to basic lighting controls including dimming, fast scenario programming, RGB lighting control, AC/DC motor control, and video monitoring. Q: W ...
... A: YES, Cantalupi USA has a turnkey lighting control system using the latest technology in Touch Screen PLC systems. The system is capable of but not limited to basic lighting controls including dimming, fast scenario programming, RGB lighting control, AC/DC motor control, and video monitoring. Q: W ...
Physics 104 Lab Handout #8
... An important property of any amplifier circuit is its frequency response. Measure and plot the voltage gain (Vout/Vin) vs. log f. Take 6 to 8 measurements, between 1Khz and 1Mhz. This transistor should have have useful response up to a few MHz. Now explore the effects of various circuit elements ( ...
... An important property of any amplifier circuit is its frequency response. Measure and plot the voltage gain (Vout/Vin) vs. log f. Take 6 to 8 measurements, between 1Khz and 1Mhz. This transistor should have have useful response up to a few MHz. Now explore the effects of various circuit elements ( ...
FN-Series and Parallel Circuits
... o Each load in a series circuit loses a portion of the total voltage so the ________________ of the voltages lost on the loads equals the total voltage supplied ...
... o Each load in a series circuit loses a portion of the total voltage so the ________________ of the voltages lost on the loads equals the total voltage supplied ...
Wet Location - Lead Calcium
... Sure-Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC-activated load switch prevents the lamps from turning on during installation to a non-energized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect ...
... Sure-Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC-activated load switch prevents the lamps from turning on during installation to a non-energized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect ...
CA800011EN
... multiple (dual voltage) switches General Eaton uses its Cooper Power™ series 300 A externally operated series multiple switch to change connection of de-energized transformer windings between series and parallel to provide different common transformer voltage ratios. They also make it possible to st ...
... multiple (dual voltage) switches General Eaton uses its Cooper Power™ series 300 A externally operated series multiple switch to change connection of de-energized transformer windings between series and parallel to provide different common transformer voltage ratios. They also make it possible to st ...
QBU Data sheet
... Pockels cell that works upon any user-defined scheme (that may be pull-up, pull-down schemes or any combinations of them). Modules provide wide range of output direct voltages (up to 6 kV). It allows operation with Pockels cells assembled on different electrooptical crystals from low quarter-wave vo ...
... Pockels cell that works upon any user-defined scheme (that may be pull-up, pull-down schemes or any combinations of them). Modules provide wide range of output direct voltages (up to 6 kV). It allows operation with Pockels cells assembled on different electrooptical crystals from low quarter-wave vo ...
SCD Encapsulated - Sola/Hevi-Duty
... SCD Series, Encapsulated, Industrial DC to DC Converter These compact, rugged DC to DC converters are power supplies designed to power industrial control instrumentation devices and equipment where AC power is not convenient or accessible. With high reliability and wide input range, these units can ...
... SCD Series, Encapsulated, Industrial DC to DC Converter These compact, rugged DC to DC converters are power supplies designed to power industrial control instrumentation devices and equipment where AC power is not convenient or accessible. With high reliability and wide input range, these units can ...
828 Datasheet
... The percent error of a meter under test may be quickly determined and directly read by use of the Model 828's Percent Error control. Analog meters may be tested for "sticky" movements by use of the run-up mode which allows voltage or current to be smoothly and continuously applied to the meter under ...
... The percent error of a meter under test may be quickly determined and directly read by use of the Model 828's Percent Error control. Analog meters may be tested for "sticky" movements by use of the run-up mode which allows voltage or current to be smoothly and continuously applied to the meter under ...
appendixD
... A function generator should be considered a variable frequency, variable voltage AC (bipolar) power supply. With the DC offset turned off the average value of the output is = 0V, but the DC offset control can be used to adjust the average value (so that the output voltage never goes below 0 VDC, for ...
... A function generator should be considered a variable frequency, variable voltage AC (bipolar) power supply. With the DC offset turned off the average value of the output is = 0V, but the DC offset control can be used to adjust the average value (so that the output voltage never goes below 0 VDC, for ...
A Power Quality Gold Mine for Prominent Hill
... reactive power, controls each phase individually, and has overload capability. Using control and monitoring software, the ability of OZ Minerals’ D-VAR solution to detect and compensate for voltage disturbances by injecting leading or lagging reactive power is well documented. The solution has reduc ...
... reactive power, controls each phase individually, and has overload capability. Using control and monitoring software, the ability of OZ Minerals’ D-VAR solution to detect and compensate for voltage disturbances by injecting leading or lagging reactive power is well documented. The solution has reduc ...
Electric Circuits
... than one path for the electric current to flow through – current flows through every path, so if one pathway is broken, it may not affect the others – The current in each path can be different depending on the devices connected to the circuit on that path ...
... than one path for the electric current to flow through – current flows through every path, so if one pathway is broken, it may not affect the others – The current in each path can be different depending on the devices connected to the circuit on that path ...
The Principles Of Dimming Leading edge dimming ? Triac
... Leading edge dimming – Triac and thyristor dimmers Leading edge dimming is a type of phase control where the turn on at each half cycle is delayed from the zero crossing point so that the first voltage presented to the load after the zero crossing is the rising or “leading” edge of the voltage. Hist ...
... Leading edge dimming – Triac and thyristor dimmers Leading edge dimming is a type of phase control where the turn on at each half cycle is delayed from the zero crossing point so that the first voltage presented to the load after the zero crossing is the rising or “leading” edge of the voltage. Hist ...
SUNNY CENTRAL 800CP XT / 850CP XT / 900CP XT
... are included, prepared for “Q at Night” including pure reactive power operation • Customized computer platform for optimal monitoring and control of inverters ...
... are included, prepared for “Q at Night” including pure reactive power operation • Customized computer platform for optimal monitoring and control of inverters ...