• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
EUP3412  1.5A/1.5MHz, Synchronous Step-Down Converter with Soft Start
EUP3412 1.5A/1.5MHz, Synchronous Step-Down Converter with Soft Start

... The ● denote the Spec. apply over the full operating temperature range, otherwise Spec. are TA=+25℃. VIN=3.6V unless otherwise specified. ...
Selecting the Optimum Transient Voltage Suppressor
Selecting the Optimum Transient Voltage Suppressor

... Typical Transient Voltage Suppressors carry peak ratings of 400, 600, 1500 or 5000 Watts. These wattages translate to 0.55, 0.80, 2.10 or 7.00 joules of energy during a 1-millisecond period. Avalanche ratings generally range from a few volts to several hundred Volts. Key operating parameters include ...
SDC1-120-12-30 - IOTA Engineering
SDC1-120-12-30 - IOTA Engineering

... The IOTA SDC1-120-12-30 delivers solid conversion of 120 Vac voltage to 13.4 Vdc for both power conversion and battery charging applications. As a power converter, the SDC1-120-12-30 tightly controls and regulates the DC output, enabling the user to safely operate any appropriate nominal DC load up ...
SDC1-120-12-75 - IOTA Engineering
SDC1-120-12-75 - IOTA Engineering

... The IOTA SDC1-120-12-75 delivers solid conversion of 120 Vac voltage to 13.6 Vdc for both power conversion and battery charging applications. As a power converter, the SDC1-120-12-75 tightly controls and regulates the DC output, enabling the user to safely operate any appropriate nominal DC load up ...
Timers Two-state Relay Type SG 125
Timers Two-state Relay Type SG 125

... 230 VAC ± 15%, 45 to 65 Hz 115 VAC ± 15%, 45 to 65 Hz 24 VAC ± 15%, 45 to 65 Hz ≥ 40 ms ≥ 2.0 kVAC (rms) (supply/elec.) Rated transient protection volt. 4 kV (1.2/50 µs) (line/neutral) Power supply DC type Installation cat. III (IEC 60664) Rated operational volt. 724 24 VDC ± 15% (pin 2 pos.) Rated ...
DANGER
DANGER

A Miniature Relay with 1-pole 3A/5A Switching Capability
A Miniature Relay with 1-pole 3A/5A Switching Capability

Saturated Enhancement Load (Cont`d)
Saturated Enhancement Load (Cont`d)

... The other NMOS device pulls down the output node The relative sizes of the two transistors determine the output voltage ...
AD580 数据手册DataSheet 下载
AD580 数据手册DataSheet 下载

... voltage in the forward-biased operating region. All such transistors have approximately a –2 mV/°C temperature coefficient, unsuitable for use directly as a low TC reference. Extrapolation of the temperature characteristic of any one of these devices to absolute zero (with an emitter current propor- ...
SDC1-120-24-25 - IOTA Engineering
SDC1-120-24-25 - IOTA Engineering

... The IOTA SDC1-120-24-25 delivers solid conversion of 120 Vac voltage to 27.2 Vdc for both power conversion and battery charging applications. As a power converter, the SDC1-120-24-25 tightly controls and regulates the DC output, enabling the user to safely operate any appropriate nominal DC load up ...
A single stage novel CCM zeta microinverter has been
A single stage novel CCM zeta microinverter has been

... A single stage novel CCM zeta microinverter has been proposed for solar PVAC module. Steady-state operation and analysis of proposed zeta microinverter in both DCM and CCM has been studied. Microinverter operation in CCM mode results in reduced conduction losses, switch ratings and current stress. T ...
LDM-1000 LVDT/RVDT Signal Conditioning Module  SPECIFICATIONS
LDM-1000 LVDT/RVDT Signal Conditioning Module SPECIFICATIONS

... Compatible with 4, 5 & 6-wire LVDTs/RVDTs Works with very low input impedance LVDTs and RVDTs ...
SDC1-120-24-40 - IOTA Engineering
SDC1-120-24-40 - IOTA Engineering

... The IOTA SDC1-120-24-40 delivers solid conversion of 120 Vac voltage to 27.2 Vdc for both power conversion and battery charging applications. As a power converter, the SDC1-120-24-40 tightly controls and regulates the DC output, enabling the user to safely operate any appropriate nominal DC load up ...
Energy efficiency of low-voltage installations
Energy efficiency of low-voltage installations

P - LSU Physics
P - LSU Physics

... In our example Pheat is almost 15 % of Ptrans and is acceptable. To keep Pheat small we must keep I rms as low as possible. The only way to accomplish this is by increasing Erms . In our example Erms = 735 kV. To do that we need a device that can change the amplitude of any ac voltage (either increa ...
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input

... The 15A rating of 120 V office power is very important and a significant limitation. Underwriters Laboratory (UL) specifies that a single piece of electronic equipment is not permitted to continuously draw more than 80% of a receptacle's rating, or 12 amps for a 15A circuit. This places a limit of a ...
Power Supply and Instrumentation Division
Power Supply and Instrumentation Division

... the personal computer. The intelligent control board in the power supply processes the command strings and performs the desired function corresponding to that command. The developed intelligent, user-friendly Graphical User Interface running in the control console guides a user’s interaction with th ...
CM-MPS.21S
CM-MPS.21S

... CM-MPS.21S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x180-280VAC The CM-MPS.21S is a multifunctional relay from the CM three-phase monitors range. It operates with a rated control supply voltage / three-phase measuring voltage of 180-280 V AC 50/60 Hz and has a 2 c/o (SPDT) output wi ...
Slide 1
Slide 1

BD63823EFV
BD63823EFV

... An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute ma ...
UMZ-442-A16-G
UMZ-442-A16-G

... [1] Frequency drift: 1MHz typical, 3MHz maximum (either extreme) ...
GCSE Physics - Physics4IGCSE
GCSE Physics - Physics4IGCSE

HQ3513331337
HQ3513331337

... wind energy. It is used without any rigour definition usually just taken to mean the voltage level is not as constant as in a „stiff grid‟. Put this way the definition of a weak grid is a grid where it is necessary to take voltage level and fluctuations into account because there is a probability th ...
Unit 8: Electronic Circuit Design and Construction
Unit 8: Electronic Circuit Design and Construction

... Draw and label a diagram of the 1N4001 general purpose diode connected in forward bias and reverse bias mode Measure the forward characteristic of the diode between 0.5 volts and 0.7 volts using steps of 0.01 of a volt by adjusting the resistance box R1 Measure and record the reverse characteristic ...
Power Sensor Theory - Herbert Dingfelder – DL5NEG
Power Sensor Theory - Herbert Dingfelder – DL5NEG

... The disadvantage is that the precision is not very high, especially when we measure at different frequencies. Like every amplifier, the log amp changes its behavior over frequencies. Of course the manufacturers of integrated log amps try to eliminate this effect as much as possible. For some time no ...
< 1 ... 1442 1443 1444 1445 1446 1447 1448 1449 1450 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report